3 resultados para Rate constant
em DigitalCommons@The Texas Medical Center
Resumo:
RC3, also known as neurogranin, is a small neuronal IQ domain protein whose only known function is to bind calmodulin (CaM). The hypothesis tested in this work was that RC3 alters the dynamics of the interaction of Ca 2+-CaM with CaM-kinase II, so that there is less CaM-kinase II activation for a given Ca2+ stimulus. To evaluate this hypothesis, we investigated the affinity and kinetics of the interactions of CaM with Ca 2+, RC3 and CaM-kinase II. We quantitated the interaction of the four CaM-kinase II isoforms with CaM and found that the KD for binding of CaM to CaM-kinase II ranged from 7 nM to 60 nM. Using stopped-flow fluorimetry, we determined the kinetics of the interaction of Ca2+-CaM with αCaM-kinase II, and found that the association rate constant is 2.1 × 10 M −1s−1 and the dissociation rate constant is 1.6 s−1. We investigated the effects of RC3 and αCaM-kinase II on the affinity of CaM for Ca2+ and found that both proteins alter the rate of dissociation of Ca2+ from CaM. RC3 increases the rate of dissociation of Ca2+ from the C-terminal binding sites of CaM from 9 s−1 to ∼500 s−1 , while αCaM-kinase II causes a decrease in the rate of dissociation from all four Ca2+ binding sites. Measurement of the rate of dissociation of Ca2+ from CaM in the presence of both RC3 and αCaM-kinase II revealed a role for RC3 in accelerating the dissociation of the Ca 2+-CaM-αCaM-kinase II complex at the end of a Ca2+ signal. We characterized the interaction of RC3 with apo-CaM and Ca 2+-CaM and found that the KD for both of these interactions is about 1 μM. We also directly tested whether RC3 slowed the dynamics of the binding of CaM to αCaM-kinase II and found that RC3 had no effect for large changes in Ca2+, and a modest effect for small changes in Ca2+ levels. Our overall conclusion is that the ability of RC3 to alter the interaction of Ca2+ with CaM allows RC3 to alter the dynamics of interaction of CaM with Ca2+-dependent targets such as CaM-kinase II. ^
ASSESSMENT OF SKELETAL MUSCLE BLOOD FLOW AND GLUCOSE METABOLISM WITH POSITRON EMITTING RADIONUCLIDES
Resumo:
In order to evaluate factors regulating substrate metabolism in vivo positron emitting radionuclides were used for the assessment of skeletal muscle blood flow and glucose utilization. The potassium analog, Rb-82 was used to measure skeletal muscle blood flow and the glucose analog, 18-F-2-deoxy-2-fluoro-D-glucose (FDG) was used to examine the kinetics of skeletal muscle transport and phosphorylation.^ New Zealand white rabbits' blood flow ranged from 1.0-70 ml/min/100g with the lowest flows occurring under baseline conditions and the highest flows were measured immediately after exercise. Elevated plasma glucose had no effect on increasing blood flow, whereas high physiologic to pharmacologic levels of insulin doubled flow as measured by the radiolabeled microspheres, but a proportionate increase was not detected by Rb-82. The data suggest that skeletal muscle blood flow can be measured using the positron emitting K+ analog Rb-82 under low flow and high flow conditions but not when insulin levels in the plasma are elevated. This may be due to the fact that insulin induces an increase in the Na+/K+-ATPase activity of the cell indirectly through a direct increase in the Na+/H+pump activity. This suggests that the increased cation pump activity counteracts the normal decrease in extraction seen at higher flows resulting in an underestimation of flow as measured by rubidium-82.^ Glucose uptake as measured by FDG employed a three compartment mathematical model describing the rates of transport, countertransport and phosphorylation of hexose. The absolute values for the metabolic rate of FDG were found to be an order of magnitude higher than those reported by other investigators. Changes noted in the rate constant for transport (k1) were found to disagree with the a priori information on the effects of insulin on skeletal muscle hexose transport. Glucose metabolism was however, found to increase above control levels with administration of insulin and electrical stimulation. The data indicate that valid measurements of skeletal muscle glucose transport and phosphorylation using the positron emitting glucose analog FDG requires further model application and biochemical validation. (Abstract shortened with permission of author.) ^
Resumo:
With continuous new improvements in brachytherapy source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters to establish PRESAGE® as a suitable brachytherapy dosimeter. The new AgX100 125I seed model (Theragenics Corporation) was then characterized using PRESAGE® following the TG-43 protocol. PRESAGE® dosimeters are solid, polyurethane-based, 3D dosimeters doped with radiochromic leuco dyes that produce a linear optical density response to radiation dose. For this project, the radiochromic response in PRESAGE® was captured using optical-CT scanning (632 nm) and the final 3D dose matrix was reconstructed using the MATLAB software. An Amersham 6711 seed with an air-kerma strength of approximately 9 U was used to irradiate two dosimeters to 2 Gy and 11 Gy at 1 cm to evaluate dose rates in the r=1 cm to r=5 cm region. The dosimetry parameters were compared to the values published in the updated AAPM Report No. 51 (TG-43U1). An AgX100 seed with an air-kerma strength of about 6 U was used to irradiate two dosimeters to 3.6 Gy and 12.5 Gy at 1 cm. The dosimetry parameters for the AgX100 were compared to the values measured from previous Monte-Carlo and experimental studies. In general, the measured dose rate constant, anisotropy function, and radial dose function for the Amersham 6711 showed agreements better than 5% compared to consensus values in the r=1 to r=3 cm region. The dose rates and radial dose functions measured for the AgX100 agreed with the MCNPX and TLD-measured values within 3% in the r=1 to r=3 cm region. The measured anisotropy function in PRESAGE® showed relative differences of up to 9% with the MCNPX calculated values. It was determined that post-irradiation optical density change over several days was non-linear in different dose regions, and therefore the dose values in the r=4 to r=5 cm regions had higher uncertainty due to this effect. This study demonstrated that within the radial distance of 3 cm, brachytherapy dosimetry in PRESAGE® can be accurate within 5% as long as irradiation times are within 48 hours.