3 resultados para Radiation fields
em DigitalCommons@The Texas Medical Center
Resumo:
The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^
Resumo:
The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1 out of the 15 head and neck cases (p=1) and 6 out of 18 breast cases (p=0.95). While MBT was not shown to be superior to IMRT, reductions were observed in doses to critical structures distal to the target along the electron beam direction and to non-target tissues, at the expense of target coverage and dose homogeneity. ^
Resumo:
The existence of an association between leukemia and electromagnetic fields (EMF) is still controversial. The results of epidemiologic studies of leukemia in occupational groups with exposure to EMF are inconsistent. Weak associations have been seen in a few studies. EMF assessment is lacking in precision. Reported dose-response relationships have been based on qualitative levels of exposure to EMF without regard to duration of employment or EMF intensity on the jobs. Furthermore, potential confounding factors in the associations were not often well controlled. The current study is an analysis of the data collected from an incident case-control study. The primary objective was to test the hypothesis that occupational exposure to EMF is associated with leukemia, including total leukemia (TL), myelogenous leukemia (MYELOG) and acute non-lymphoid leukemia (ANLL). Potential confounding factors: occupational exposure to benzene, age, smoking, alcohol consumption, and previous medical radiation exposures were controlled in multivariate logistic regression models. Dose-response relationships were estimated by cumulative occupational exposure to EMF, taking into account duration of employment and EMF intensity on the jobs. In order to overcome weaknesses of most previous studies, special efforts were made to improve the precision of EMF assessment. Two definitions of EMF were used and result discrepancies using the two definitions were observed. These difference raised a question as to whether the workers at jobs with low EMF exposure should be considered as non-exposed in future studies. In addition, the current study suggested use of lifetime cumulative EMF exposure estimates to determine dose-response relationship. The analyses of the current study suggest an association between ANLL and employment at selected jobs with high EMF exposure. The existence of an association between three types of leukemia and broader categories of occupational EMF exposure, is still undetermined. If an association does exist between occupational EMF exposure and leukemia, the results of the current study suggest that EMF might only be a potential factor in the promotion of leukemia, but not its initiation. ^