4 resultados para Quality criteria

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Many users search the Internet for answers to health questions. Complementary and alternative medicine (CAM) is a particularly common search topic. Because many CAM therapies do not require a clinician's prescription, false or misleading CAM information may be more dangerous than information about traditional therapies. Many quality criteria have been suggested to filter out potentially harmful online health information. However, assessing the accuracy of CAM information is uniquely challenging since CAM is generally not supported by conventional literature. OBJECTIVE: The purpose of this study is to determine whether domain-independent technical quality criteria can identify potentially harmful online CAM content. METHODS: We analyzed 150 Web sites retrieved from a search for the three most popular herbs: ginseng, ginkgo and St. John's wort and their purported uses on the ten most commonly used search engines. The presence of technical quality criteria as well as potentially harmful statements (commissions) and vital information that should have been mentioned (omissions) was recorded. RESULTS: Thirty-eight sites (25%) contained statements that could lead to direct physical harm if acted upon. One hundred forty five sites (97%) had omitted information. We found no relationship between technical quality criteria and potentially harmful information. CONCLUSIONS: Current technical quality criteria do not identify potentially harmful CAM information online. Consumers should be warned to use other means of validation or to trust only known sites. Quality criteria that consider the uniqueness of CAM must be developed and validated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Inefficiencies during the management of healthcare waste can give rise to undesirable health effects such as transmission of infections and environmental pollution within and beyond the health facilities generating these wastes. Factors such as prevalence of diseases, conflicts, and the efflux of intellectual capacity make low income countries more susceptible to these adverse health effects. The purpose of this systematic review was to describe the effectiveness of interventions geared towards better managing the generation, collection, transport, treatment and disposal of medical waste, as they have been applied in lower and middle income countries.^ Using a systematic search strategy and evaluation of study quality, this study reviewed the literature for published studies on healthcare waste management interventions carried out in developing countries, specifically the low and lower middle income countries from year 2000 to the current year. From an initially identified set of 829 studies, only three studies ultimately met all inclusion, exclusion and high quality criteria. A multi component intervention in Syrian Arab Republic, conducted in 2007 was aimed at improving waste segregation practice in a hospital setting. There was an increased use of segregation boxes and reduced rates of sharps injury among staff as a result of the intervention. Another study, conducted in 2008, trained medical students as monitors of waste segregation practice in an Indian teaching hospital. There was improved practice in wards and laboratories but not in the intensive care units. The third study, performed in 2008 in China, consisted of modification of the components of a medical waste incinerator to improve efficiency and reduce stack emissions. Gaseous pollutants emitted, except polychlorodibenzofurans (PCDF) were below US EPA permissible exposure limits. Heavy metal residues in the fly ash remained unchanged.^ Due to the paucity of well-designed studies, there is insufficient evidence in literature to conclude on the effectiveness of interventions in low income settings. There is suggestive but insufficient evident that multi-component interventions aimed at improving waste segregation through behavior modification, provision of segregation tools and training of monitors are effective in low income settings.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Public health departments play an important role in promoting and preserving the health of communities. The lack of a system to ensure their quality and accountability led to the development of a national voluntary accreditation program by Public Health Accreditation Board (PHAB). The concept that accreditation will lead to quality improvement in public health which will ultimately lead to healthy communities seems intuitive but lacks a robust body of evidence. A critical review of literature was conducted to explore if accreditation can lead to quality improvement in public health. The articles were selected from publically available databases using a specific set of criteria for inclusion, exclusion, and appraisal. To understand the relationship between accreditation and quality improvement, the potential strengths and limitations of accreditation process were evaluated. Recommendations for best practices are suggested so that public health accreditation can yield maximum benefits. A logic model framework to help depict the impact of accreditation on various levels of public health outcomes is also discussed in this thesis. The literature review shows that existing accreditation programs in other industries show limited but encouraging evidence that accreditation will improve quality and strengthen the delivery of public health services. While progress in introducing accreditation in public health can be informed by other accredited industries, the public health field has its own set of challenges. Providing incentives, creating financing strategies, and having a strong leadership will allow greater access to accreditation by all public health departments. The suggested recommendations include that continuous evaluation, public participation, systems approach, clear vision, and dynamic standards should become hallmarks of the accreditation process. Understanding the link between accreditation, quality improvement, and health outcomes will influence the successful adoption and implementation of the public health accreditation program. This review of literature suggests that accreditation is an important step in improving the quality of public health departments and in ultimately improving the health of communities. However, accreditation should be considered in an integrated system of tools and approaches to improve the public health practice. Hence, it is a means to an end - not an end unto itself.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a replacement for TLD in the QA phantoms. A 10 cm diameter high-impact polystyrene spherical phantom was designed and constructed to hold an OSLD to study the angular response of the dosimeter under the simplest of circumstances for both coplanar and non-coplanar treatment deliveries. OSLD were irradiated in the spherical phantom, and the responses of the dosimeter from edge-on angles were normalized to the response when irradiated with the beam incident normally on the surface of the dosimeter. The average normalized response was used to establish an angular correction factor for 6 MV and 18 coplanar treatments, and for 6 MV non-coplanar treatments specific to CyberKnife. The RPC pelvic phantom dosimetry insert was modified to hold OSLD, in addition to the TLD, adjacent to the planes of film. Treatment plans of increasing angular beam delivery were developed, three in Pinnacle v9.0 (4-field box, IMRT, and VMAT) and one in Accuray’s MultiPlan v3.5.3 (CyberKnife). The plans were delivered to the pelvic phantom containing both TLD and OSLD in the target volume. The pelvic phantom was also sent to two institutions to be irradiated as trials, one delivering IMRT, and the other a CyberKnife treatment. For the IMRT deliveries and the two institution trials, the phantom also included film in the sagittal and coronal planes. The doses measured from the TLD and OSLD were calculated for each irradiation, and the angular correction factors established from the spherical phantom irradiations were applied to the OSLD dose. The ratio of the TLD dose to the angular corrected OSLD dose was calculated for each irradiation. The corrected OSLD dose was found to be within 1% of the TLD measured dose for all irradiations, with the exception of the in-house CyberKnife deliveries. The films were normalized to both TLD measured dose and the corrected OSLD dose. Dose profiles were obtained and gamma analysis was performed using a 7%/4 mm criteria, to compare the ability of the OSLD, when corrected for the angular dependence, to provide equivalent results to TLD. The results of this study indicate that the OSLD can effectively be used as a replacement for TLD in the RPC’s anthropomorphic QA phantoms for coplanar treatment deliveries when a correction is applied for the dosimeter’s angular dependence.