2 resultados para PHYSICAL PROTECTION DEVICES

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to the clinical success of left ventricular assist devices (LVADs) used for short term "bridge to transplant" and the limited availability of donor organs, heart assist devices are being considered for long term implantation as an alternative to heart transplantation. In an effort to improve biocompatibility, a nonthrombogenic cellular lining was developed from genetically engineered smooth muscle cells (GE-SMC) for the Thermocardiosystems Heartmate$\sp{\rm TM}$ LVAD. SMCs have been transduced with the genes for endothelial nitric oxide synthase (NOS III) and GTP cyclohydrolase (GTPCH) with subsequent stable expression of the NOS III protein via an Epstein Barr based DNA expression vector. Transduced SMCs produce nitric oxide at concentrations that reduce platelet deposition and smooth muscle cell proliferation when tested in vitro. In addition, the adhesive capabilities of GE-SMC linings were also examined, and optimized in physical environments mimicking typical in vivo LVAD operation. Preliminary investigations examining cell adhesion during constant shear stress exposure demonstrated an acute phase of cell loss corresponding to cytoskeletal F-actin rearrangement. Subsequently, an in vitro circulatory loop was designed to expose cell lined LVADs to in vivo operating conditions. Cumulative cell loss from cell lined LVADs was less than 10% after 24 hours of flow. Using a protocol for "preconditioning" the cell lining within the mock circulatory loop, the first implantation of an LVAD containing a genetically engineered SMC lining was successfully implemented in a bovine model. Results from this 24 hour study indicate that the flow-conditioned cellular lining remained intact with no evidence of thromboembolization and only minimal changes in coagulation studies. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Ambulatory blood pressure (ABP) measurement is a means of monitoring cardiac function in a noninvasive way, but little is known about ABP in heart failure (HF) patients. Blood pressure (BP) declines during sleep as protection from consistent BP load, a phenomenon termed "dipping." The aims of this study were (1) to compare BP dipping and physical activity between two groups of HF patients with different functional statuses and (2) to determine whether the strength of the association between ambulatory BP and PA is different between these two different functional statuses of HF. ^ Methods. This observational study used repeated measures of ABP and PA over a 24-hour period to investigate the profiles of BP and PA in community-based individuals with HF. ABP was measured every 30 minutes by using a SpaceLabs 90207, and a Basic Motionlogger actigraph was used to measure PA minute by minute. Fifty-six participants completed both BP and physical activity for a 24-hour monitoring period. Functional status was based on New York Heart Association (NYHA) ratings. There were 27 patients with no limitation of PA (NYHA class I HF) and 29 with some limitation of PA but no discomfort at rest (NYHA class II or III HF). The sample consisted of 26 men and 30 women, aged 45 to 91 years (66.96 ± 12.35). ^ Results. Patients with NYHA class I HF had significantly greater dipping percent than those with NYHA class II/III HF after controlling their left ventricular ejection fraction (LVEF). In a mixed model analysis (PROC MIXED, SAS Institute, v 9.1), PA was significantly related to ambulatory systolic and diastolic BP and mean arterial pressure. The strength of the association between PA and ABP readings was not significantly different for the two groups of patients. ^ Conclusions. These preliminary findings demonstrate differences between NYHA class I and class II/III of HF in BP dipping status and ABP but not PA. Longitudinal research is recommended to improve understanding of the influence of disease progression on changes in 24-hour physical activity and BP profiles of this patient population. ^ Key Words. Ambulatory Blood Pressure; Blood Pressure Dipping; Heart Failure; Physical Activity. ^