7 resultados para Onward moves
em DigitalCommons@The Texas Medical Center
Resumo:
The bone marrow accommodates hematopoietic stem cells and progenitors. These cells provide an indispensible resource for replenishing the blood constituents throughout an organism’s life. A tissue with such a high turn-over rate mandates intact cycling checkpoint and apoptotic pathways to avoid inappropriate cell proliferation and ultimately the development of leukemias. p53, a major tumor suppressor, is a transcription factor that regulates cell cycle, and induces apoptosis and senescence. Mice inheriting a hypomorphic p53 allele in the absence of Mdm2, a p53 inhibitor, have elevated p53 cell cycle activity and die by postnatal day 13 due to hematopoietic failure. Hematopoiesis progresses normally during embryogenesis until it moves to the bone marrow in late development. Increased oxidative stress in the bone marrow compartment postnatally is the impediment for normal hematopoiesis via activation of p53. p53 in turn stimulates the generation of more reactive oxygen species and depletes bone marrow cellularity. Also, p53 exerts various defects on the hematopoietic niche by increasing mesenchymal lineage populations and their differentiation. Hematopoietic defects are rescued with antioxidants or when cells are cultured at low oxygen levels. Deletion of p16 partially rescues bone marrow cellularity and progenitors via a p53-independent pathway. Thus, although p53 is required to inhibit tumorigenesis, Mdm2 is required to control ROS-induced p53 levels for sustainable hematopoiesis and survival during homeostasis.
Resumo:
The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to define the volume that encompasses the motion envelope of the moving gross target volume (GTV). Because of the close relationship that exists between the MIP and the final target volume, we investigated four MIP data sets created with different methodologies (3 using various 4D-CT sorting implementations, and one using all available cine CT images) to compare target delineation. It has been observed that changing the 4D-CT sorting method will lead to the selection of a different collection of images; however, the clinical implications of changing the constituent images on the resultant MIP data set are not clear. There has not been a comprehensive study that compares target delineation based on different 4D-CT sorting methodologies in a patient population. We selected a collection of patients who had previously undergone thoracic 4D-CT scans at our institution, and who had lung tumors that moved at least 1 cm. We then generated the four MIP data sets and automatically contoured the target volumes. In doing so, we identified cases in which the MIP generated from a 4D-CT sorting process under-represented the motion envelope of the target volume by more than 10% than when measured on the MIP generated from all of the cine CT images. The 4D-CT methods suffered from duplicate image selection and might not choose maximum extent images. Based on our results, we suggest utilization of a MIP generated from the full cine CT data set to ensure a representative inclusive tumor extent, and to avoid geometric miss.
Resumo:
Subfields of the hippocampus display differential dynamics in processing a spatial environment, especially when changes are introduced to the environment. Specifically, when familiar cues in the environment are spatially rearranged, place cells in the CA3 subfield tend to rotate with a particular set of cues (e.g., proximal cues), maintaining a coherent spatial representation. Place cells in CA1, in contrast, display discordant behaviors (e.g., rotating with different sets of cues or remapping) in the same condition. In addition, on average, CA3 place cells shift their firing locations (measured by the center of mass, or COM) backward over time when the animal encounters the changed environment for the first time, but not after that first experience. However, CA1 displays an opposite pattern, in which place cells exhibit the backward COM-shift only from the second day of experience, but not on the first day. Here, we examined the relationship between the environment-representing behavior (i.e., rotation vs. remapping) and the COM-shift of place fields in CA1 and CA3. Both in CA1 and CA3, the backward (as well as forward) COM-shift phenomena occurred regardless of the rotating versus remapping of the place cell. The differential, daily time course of the onset/offset of backward COM-shift in the cue-altered environment in CA1 and CA3 (on day 1 in CA1 and from day 2 onward in CA3) stems from different population dynamics between the subfields. The results suggest that heterogeneous, complex plasticity mechanisms underlie the environment-representating behavior (i.e., rotate/remap) and the COM-shifting behavior of the place cell.
Resumo:
SRI is unique among known photoreceptors in that it produces opposite signals depending on the color of light stimuli. Absorption of orange light (587 nm) triggers an attractant response by the cell, whereas absorption of orange light followed by near-UV light (373 run) triggers a repellent response. Using behavioral mutants that exhibit aberrant color-sensing ability, we tested a two-conformation equilibrium model, using FRET and EPR spectroscopy. The essence of the model applied to SRI-HtrI is that the complex exists in a metastable two-conformer equilibrium which is shifted in one direction by orange light absorption (producing an attractant signal) and in the opposite direction by a second UV-violet photon (producing a repellent signal). First, by FRET we found that the E-F cytoplasmic loop of SRI moves toward the RAMP domain of the HtrI transducer during the formation of the orange-light activated signaling state of the complex. This is the first localization of a change in the physical relationship between the receptor and transducer subunits of the complex and provides a structural property of the two proposed conformers that we can monitor. Second, EPR spectra of a spin label probe at this cytoplasmic position showed shifts in the dark in the mutants toward shorter or longer EF loop-RAMP distances, explaining their behavior in terms of their mutations causing pre-stimulus shifts into one or the other conformer. ^ Next, we applied a novel electrophysiological method for monitoring the directionality of proton movement during photoactivation of SRI, to investigate the process of proton transfer in the photoactive site from the chromophore to proton acceptors on both the wildtype and aberrant color-response mutants. We observed an unexpected and critical difference in the two signaling conformations of the SRI-HtrI complex. The finding is that the vectoriality (i.e. movement away or toward the cytoplasm) of the light-induced proton transfer from the chromophore to the protein is opposite in formation of the two conformations. Retinylidene proton transfer is a common critical process in rhodopsins and these results are the first to show differences in vectoriality in a rhodopsin receptor, and to demonstrate functional importance of the direction of proton transfer. ^
Resumo:
Leukopenia, the leukocyte count, and prognosis of disease are interrelated; a systematic search of the literature was undertaken to ascertain the strength of the evidence. One hundred seventy-one studies were found from 1953 onward pertaining to the predictive capabilities of the leukocyte count. Of those studies, 42 met inclusion criteria. An estimated range of 2,200cells/μL to 7,000cells/μL was determined as that which indicates good prognosis in disease and indicates the least amount of risk to an individual overall. Tables of the evidence are included indicating the disparate populations examined and the possible degree of association. ^
Resumo:
The clinical advantage for protons over conventional high-energy x-rays stems from their unique depth-dose distribution, which delivers essentially no dose beyond the end of range. In order to achieve it, accurate localization of the tumor volume relative to the proton beam is necessary. For cases where the tumor moves with respiration, the resultant dose distribution is sensitive to such motion. One way to reduce uncertainty caused by respiratory motion is to use gated beam delivery. The main goal of this dissertation is to evaluate the respiratory gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the parameters of synchrotron operation and respiratory gating can lead to greater efficiency and accuracy of respiratory gating for all modes of synchrotron-based proton treatment delivery. The hypothesis is tested in two specific aims. The specific aim #1 is to assess the efficiency of respiratory-gated proton beam delivery and optimize the synchrotron operations for the gated proton therapy. A simulation study was performed and introduced an efficient synchrotron operation pattern, called variable Tcyc. In addition, the simulation study estimated the efficiency in the respiratory gated scanning beam delivery mode as well. The specific aim #2 is to assess the accuracy of beam delivery in respiratory-gated proton therapy. The simulation study was extended to the passive scattering mode to estimate the quality of pulsed beam delivery to the residual motion for several synchrotron operation patterns with the gating technique. The results showed that variable Tcyc operation can offer good reproducible beam delivery to the residual motion at a certain phase of the motion. For respiratory gated scanning beam delivery, the impact of motion on the dose distributions by scanned beams was investigated by measurement. The results showed the threshold for motion for a variety of scan patterns and the proper number of paintings for normal and respiratory gated beam deliveries. The results of specific aims 1 and 2 provided supporting data for implementation of the respiratory gating beam delivery technique into both passive and scanning modes and the validation of the hypothesis.
Resumo:
Over the last decade, adverse events and medical errors have become a main focus of interest for the standards of quality and safety in the U.S. healthcare system (Weinstein & Henderson, 2009). Particularly when a medical error occurs, the disclosure of medical errors and its practices have become a focal point of the healthcare process. Patients and family members who have experienced a medical error might be able to provide knowledge and insight on how to improve the disclose process. However, patient and family member are not typically involved in the disclosure process, thus their experiences go unnoticed. ^ The purpose of this research was to explore how best to include patients and family members in the disclosure process regarding a medical error. The research consisted of 28 qualitative interviews from three stakeholder groups: Hospital Administrators, Clinical Service Providers, and Patients and Family Members. They were asked for their ideas and suggestions on how best to include patients and family members in the disclosure process. Framework Analysis was used to analyze this data and find prevalent themes based on the primary research question. A secondary aim was to index categories created based on the interviews that were collected. Data was used from the Texas Disclosure and Compensation Study with Dr. Eric Thomas as the Principal Investigator. Full acknowledgement of access to this data is given to Dr. Thomas. ^ The themes from the research revealed that each stakeholder group was interested and open to including patients and family members in the disclosure process and that the disclosure process should not be a "one-way" avenue. The themes gave many suggestions regarding how to best include patients and family members in the disclosure process of a medical error. Secondary aims revealed several ways to assess the ideas and suggestion given by the stakeholders. Overall, acceptability of getting the perspective of patients and family members was the most common theme. Comparison of each stakeholder group revealed that including patients and family members would be beneficial to improving hospital disclosure practices. ^ Conclusions included a list of recommendations and measureable appropriate strategies that could provide hospital with key stakeholders insights on how to improve their disclosure process. Sharing patients and family members experience with healthcare providers can encourage a shift in culture where patients are valued and active in participating in hospital practices. To my knowledge, this research is the very first of its kind and moves the disclosure process conversation forward in a patient-family member inclusion direction that will assist in improving disclosure practices. Future research should implement and evaluate the success of the various inclusion strategies.^