3 resultados para Non-commutative particles dynamics

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Treatment of central nervous system (CNS) diseases is limited by the blood-brain barrier (BBB), a selective vascular interface restricting passage of most molecules from blood into brain. Specific transport systems have evolved allowing circulating polar molecules to cross the BBB and gain access to the brain parenchyma. However, to date, few ligands exploiting such systems have proven clinically viable in the setting of CNS diseases. We reasoned that combinatorial phage-display screenings in vivo would yield peptides capable of crossing the BBB and allow for the development of ligand-directed targeting strategies of the brain. Here we show the identification of a peptide mediating systemic targeting to the normal brain and to an orthotopic human glioma model. We demonstrate that this peptide functionally mimics iron through an allosteric mechanism and that a non-canonical association of (i) transferrin, (ii) the iron-mimic ligand motif, and (iii) transferrin receptor mediates binding and transport of particles across the BBB. We also show that in orthotopic human glioma xenografts, a combination of transferrin receptor over-expression plus extended vascular permeability and ligand retention result in remarkable brain tumor targeting. Moreover, such tumor targeting attributes enables Herpes simplex virus thymidine kinase-mediated gene therapy of intracranial tumors for molecular genetic imaging and suicide gene delivery with ganciclovir. Finally, we expand our data by analyzing a large panel of primary CNS tumors through comprehensive tissue microarrays. Together, our approach and results provide a translational avenue for the detection and treatment of brain tumors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An investigation was undertaken to evaluate the role of fomites in the transmission of diarrhea in day-care centers (DCC) and to elucidate the paths by which enteric organisms spread within this setting.^ During a nine-month period (December 1980-August 1981) extensive culturing of inanimate objects, as well as children and staff was done routinely each month and again repeated during diarrhea outbreaks. Air was sampled from the classrooms and toilets using a Single-Stage Sieve Sampler (Ross Industries, Midland, VA.). Stool samples were collected from both ill and well children and staff in the affected rooms only during outbreaks. Environmental samples were processed for Shigella, salmonella and fecal coliforms while stools were screened for miscellaneous enteropathogens.^ A total of 11 outbreaks occurred in the 5 DCC during the study period. Enteric pathogens were recovered in 7 (64%) of the outbreaks. Multiple pathogens were identified in 3 outbreaks. The most frequently identified pathogen in stools was Giardia lamblia which was recovered in 5 (45%) of the outbreaks. Ten of the 11 (91%) outbreaks occurred in children less than 12 months of age.^ Environmental microbiology studies together with epidemiologic information revealed that enteric organisms were transmitted from person-to-person. On routine sampling, fecal coliforms were most frequently isolated from tap handles and diaper change areas. Contamination with fetal coliforms was wide-spread during diarrhea outbreaks. Fecal coliforms were recovered with significantly greater frequency from hands, toys and other classroom objects during outbreaks than during non-outbreak period. Salmonella typhimurium was recovered from a table top during an outbreak of Salmonellosis. There was no association between the level of enteric microbial contamination in the toilet areas and the occurrence of outbreaks. No evidence was found to indicate that enteric organisms were spread by the airborne route via aerosols.^ Toys, other classroom objects and contaminated hands probably play a major role in the transmission of enteropathogens during day-care center outbreaks. The presence of many enteric agents in the environment undoubtedly explains the polymicrobial etiology of the day-care center associated diarrhea outbreaks. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^