7 resultados para Musculoskeletal ultrasound

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Musculoskeletal infections are infections of the bone and surrounding tissues. They are currently diagnosed based on culture analysis, which is the gold standard for pathogen identification. However, these clinical laboratory methods are frequently inadequate for the identification of the causative agents, because a large percentage (25-50%) of confirmed musculoskeletal infections are false negatives in which no pathogen is identified in culture. My data supports these results. The goal of this project was to use PCR amplification of a portion of the 16S rRNA gene to test an alternative approach for the identification of these pathogens and to assess the diversity of the bacteria involved. The advantages of this alternative method are that it should increase sample sensitivity and the speed of detection. In addition, bacteria that are non-culturable or in low abundance can be detected using this molecular technique. However, a complication of this approach is that the majority of musculoskeletal infections are polymicrobial, which prohibits direct identification from the infected tissue by DNA sequencing of the initial 16S rDNA amplification products. One way to solve this problem is to use denaturing gradient gel electrophoresis (DGGE) to separate the PCR products before DNA sequencing. Denaturing gradient gel electrophoresis (DGGE) separates DNA molecules based on their melting point, which is determined by their DNA sequence. This analytical technique allows a mixture of PCR products of the same length that electrophoreses through agarose gels as one band, to be separated into different bands and then used for DNA sequence analysis. In this way, the DGGE allows for the identification of individual bacterial species in polymicrobial-infected tissue, which is critical for improving clinical outcomes. By combining the 16S rDNA amplification and the DGGE techniques together, an alternative approach for identification has been used. The 16S rRNA gene PCR-DGGE method includes several critical steps: DNA extraction from tissue biopsies, amplification of the bacterial DNA, PCR product separation by DGGE, amplification of the gel-extracted DNA, and DNA sequencing and analysis. Each step of the method was optimized to increase its sensitivity and for rapid detection of the bacteria present in human tissue samples. The limit of detection for the DNA extraction from tissue was at least 20 Staphylococcus aureus cells and the limit of detection for PCR was at least 0.05 pg of template DNA. The conditions for DGGE electrophoreses were optimized by using a double gradient of acrylamide (6 – 10%) and denaturant (30-70%), which increased the separation between distinct PCR products. The use of GelRed (Biotium) improved the DNA visualization in the DGGE gel. To recover the DNA from the DGGE gels the gel slices were excised, shredded in a bead beater, and the DNA was allowed to diffuse into sterile water overnight. The use of primers containing specific linkers allowed the entire amplified PCR product to be sequenced and then analyzed. The optimized 16S rRNA gene PCR-DGGE method was used to analyze 50 tissue biopsy samples chosen randomly from our collection. The results were compared to those of the Memorial Hermann Hospital Clinical Microbiology Laboratory for the same samples. The molecular method was congruent for 10 of the 17 (59%) culture negative tissue samples. In 7 of the 17 (41%) culture negative the molecular method identified a bacterium. The molecular method was congruent with the culture identification for 7 of the 33 (21%) positive cultured tissue samples. However, in 8 of the 33 (24%) the molecular method identified more organisms. In 13 of the 15 (87%) polymicrobial cultured tissue samples the molecular method identified at least one organism that was also identified by culture techniques. Overall, the DGGE analysis of 16S rDNA is an effective method to identify bacteria not identified by culture analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the perception and knowledge of targeted ultrasound in women who screen positive for Down syndrome in the first or second trimester, and to assess the perceived detection rate of Down syndrome by targeted ultrasound in this population. While several studies have reported patient perceptions’ of routine ultrasound, no study has specifically examined knowledge regarding the targeted ultrasound and its role in detecting Down syndrome. A targeted ultrasound is a special ultrasound during the second trimester offered to women who may be at a higher-than-average risk of having a baby with some type of birth defect or complication. The purpose of the ultrasound is to evaluate the overall growth and development of the baby as well as screen for birth defects and genetic conditions. Women under the age of 35 referred for an abnormal first or second trimester maternal serum screen to several Houston area clinics were asked to complete a questionnaire to obtain demographic and ultrasound knowledge information as well as assess perceived detection rate of Down syndrome by ultrasound. Seventy-seven women completed the questionnaire and participated in the study. Our findings revealed that women have limited background knowledge about the targeted ultrasound and its role in detecting Down syndrome. These findings are consistent with other studies that have reported a lack of understanding about the purpose of ultrasound examinations. One factor that seems to increase background knowledge about the targeted ultrasound is individuals having a higher level of education. However, most participants regardless of race, education, income, and exposure to targeted ultrasound information did not know the capabilities of a targeted ultrasound. This study confirmed women lack background knowledge about the targeted ultrasound and do not know enough about the technology to form a perception regarding its ability to detect Down syndrome. Additional studies to identify appropriate education techniques are necessary to determine how to best inform our patient population about targeted ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Cigarette smoking during pregnancy is associated with poor maternal and child health outcomes. Effective interventions to increase smoking cessation rates are needed particularly for pregnant women unable to quit in their first trimester. Real-time ultrasound feedback focused on potential effects of smoking on the fetus may be an effective treatment adjunct, improving smoking outcomes. METHODS: A prospective randomized trial was conducted to evaluate the efficacy of a smoking cessation intervention consisting of personalized feedback during ultrasound plus motivational interviewing-based counseling sessions. Pregnant smokers (N = 360) between 16 and 26 weeks of gestation were randomly assigned to one of three groups: Best Practice (BP) only, Best Practice plus ultrasound feedback (BP+US), or Motivational Interviewing-based counseling plus ultrasound feedback (MI+US). Assessments were conducted at baseline and end of pregnancy (EOP). RESULTS: Analyses of cotinine-verified self-reported smoking status at EOP indicated that 10.8% of the BP group was not smoking at EOP; 14.2% in the BP+US condition and 18.3% who received MI+US were abstinent, but differences were not statistically significant. Intervention effects were found conditional upon level of baseline smoking, however. Nearly 34% of light smokers (< or =10 cigarettes/day) in the MI+US condition were abstinent at EOP, followed by 25.8% and 15.6% in the BP+US and BP conditions, respectively. Heavy smokers (>10 cigarettes/day) were notably unaffected by the intervention. DISCUSSION: Future research should confirm benefit of motivational interviewing plus ultrasound feedback for pregnant light smokers and explore mechanisms of action. Innovative interventions for pregnant women smoking at high levels are sorely needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current standard for temperature sensitive imaging using magnetic resonance (MR) is 2-D, spoiled, fast gradient-echo (fGRE) phase-difference imaging exploiting temperature dependent changes in the proton resonance frequency (PRF). The echo-time (TE) for optimal sensitivity is larger than the typical repetition time (TR) of an fGRE sequence. Since TE must be less than TR in the fGRE sequence, this limits the technique's achievable sensitivity, spatial, and temporal resolution. This adversely affects both accuracy and volume coverage of the measurements. Accurate measurement of the rapid temperature changes associated with pulsed thermal therapies, such as high-intensity focused ultrasound (FUS), at optimal temperature sensitivity requires faster acquisition times than those currently available. ^ Use of fast MR acquisition strategies, such as interleaved echo-planar and spiral imaging, can provide the necessary increase in temporal performance and sensitivity while maintaining adequate signal-to-noise and in-plane spatial resolution. This research explored the adaptation and optimization of several fast MR acquisition methods for thermal monitoring of pulsed FUS thermal therapy. Temperature sensitivity, phase-difference noise and phase-difference to phase-difference-to noise ratio for the different pulse sequences were evaluated under varying imaging parameters in an agar gel phantom to establish optimal sequence parameters for temperature monitoring. The temperature sensitivity coefficient of the gel phantom was measured, allowing quantitative temperature extrapolations. ^ Optimized fast sequences were compared based on the ability to accurately monitor temperature changes at the focus of a high-intensity focused ultrasound unit, volume coverage, and contrast-to-noise ratio in the temperature maps. Operating parameters, which minimize complex phase-difference measurement errors introduced by use of the fast-imaging methods, were established. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two studies among college students were conducted to evaluate appropriate measurement methods for etiological research on computing-related upper extremity musculoskeletal disorders (UEMSDs). ^ A cross-sectional study among 100 graduate students evaluated the utility of symptoms surveys (a VAS scale and 5-point Likert scale) compared with two UEMSD clinical classification systems (Gerr and Moore protocols). The two symptom measures were highly concordant (Lin's rho = 0.54; Spearman's r = 0.72); the two clinical protocols were moderately concordant (Cohen's kappa = 0.50). Sensitivity and specificity, endorsed by Youden's J statistic, did not reveal much agreement between the symptoms surveys and clinical examinations. It cannot be concluded self-report symptoms surveys can be used as surrogate for clinical examinations. ^ A pilot repeated measures study conducted among 30 undergraduate students evaluated computing exposure measurement methods. Key findings are: temporal variations in symptoms, the odds of experiencing symptoms increased with every hour of computer use (adjOR = 1.1, p < .10) and every stretch break taken (adjOR = 1.3, p < .10). When measuring posture using the Computer Use Checklist, a positive association with symptoms was observed (adjOR = 1.3, p < 0.10), while measuring posture using a modified Rapid Upper Limb Assessment produced unexpected and inconsistent associations. The findings were inconclusive in identifying an appropriate posture assessment or superior conceptualization of computer use exposure. ^ A cross-sectional study of 166 graduate students evaluated the comparability of graduate students to College Computing & Health surveys administered to undergraduate students. Fifty-five percent reported computing-related pain and functional limitations. Years of computer use in graduate school and number of years in school where weekly computer use was ≥ 10 hours were associated with pain within an hour of computing in logistic regression analyses. The findings are consistent with current literature on both undergraduate and graduate students. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is a secondary data analysis of the CUPID-INCA Nicaragua study, a cross-sectional study comparing psychosocial and physical factors on musculoskeletal symptoms among nurses, office workers and maquiladoras in Nicaragua. There were three objectives for this thesis. (1) To describe the study population according to their socio-demographic, psychosocial (i.e. work organization and health beliefs) and physical factors. (2) To estimate the prevalence of musculoskeletal disorders (MSDs) in the study population (nurses, office workers and maquilas). (3) To analyze and compare the trends of association between psychosocial factors and MSDs to that of physical factors and MSDs in the study population. Trends of association between MSDs and psychosocial factors were also compared between nurses, office workers and maquilas. ^ Majority of the total study population were females, middle aged, non smokers and had been on the job for more than five years. Prevalence rates of low back pain and upper extremity pain were 28% and 37% respectively in nurses, 17% and 34% in office workers and 18% and 31% in maquilas. Workers' health belief was significantly associated with MSDs in all three occupational groups. Psychosocial factors were not consistently associated more with MSDs than physical factors. Maquilas had more psychosocial factors statistically significantly associated with musculoskeletal symptoms than nurses and office workers. ^ The findings of this research suggest that both psychosocial and physical risk factors play a role on the prevalence of musculoskeletal symptoms in the three working populations in Nicaragua. Future research in this area should explore further, the risk of developing MSDs from workers' exposure to psychosocial factors as well as physical factors.^