3 resultados para Motion perception (Vision)
em DigitalCommons@The Texas Medical Center
Resumo:
We seek to determine the relationship between threshold and suprathreshold perception for position offset and stereoscopic depth perception under conditions that elevate their respective thresholds. Two threshold-elevating conditions were used: (1) increasing the interline gap and (2) dioptric blur. Although increasing the interline gap increases position (Vernier) offset and stereoscopic disparity thresholds substantially, the perception of suprathreshold position offset and stereoscopic depth remains unchanged. Perception of suprathreshold position offset also remains unchanged when the Vernier threshold is elevated by dioptric blur. We show that such normalization of suprathreshold position offset can be attributed to the topographical-map-based encoding of position. On the other hand, dioptric blur increases the stereoscopic disparity thresholds and reduces the perceived suprathreshold stereoscopic depth, which can be accounted for by a disparity-computation model in which the activities of absolute disparity encoders are multiplied by a Gaussian weighting function that is centered on the horopter. Overall, the statement "equal suprathreshold perception occurs in threshold-elevated and unelevated conditions when the stimuli are equally above their corresponding thresholds" describes the results better than the statement "suprathreshold stimuli are perceived as equal when they are equal multiples of their respective threshold values."
Resumo:
Despite rapid to-and-fro motion of the retinal image that results from their incessant involuntary eye movements, persons with infantile nystagmus (IN) rarely report the perception of motion smear. We performed two experiments to determine if the reduction of perceived motion smear in persons with IN is associated with an increase in the speed of the temporal impulse response. In Experiment 1, increment thresholds were determined for pairs of successively presented flashes of a long horizontal line, presented on a 65-cd/m2 background field. The stimulus-onset asynchrony (SOA) between the first and second flash varied from 5.9 to 234 ms. In experiment 2, temporal contrast sensitivity functions were determined for a 3-cpd horizontal square-wave grating that underwent counterphase flicker at temporal frequencies between 1 and 40 Hz. Data were obtained for 2 subjects with predominantly pendular IN and 8 normal observers in Experiment 1 and for 3 subjects with IN and 4 normal observers in Experiment 2. Temporal impulse response functions (TIRFs) were estimated as the impulse response of a linear second-order system that provided the best fit to the increment threshold data in Experiment 1 and to the temporal contrast sensitivity functions in Experiment 2. Estimated TIRFs of the subjects with pendular IN have natural temporal frequencies that are significantly faster than those of normal observers (ca. 13 vs. 9 Hz), indicating an accelerated temporal response to visual stimuli. This increase in response speed is too small to account by itself for the virtual absence of perceived motion smear in subjects with IN, and additional neural mechanisms are considered.
Resumo:
Retinal detachment is a common ophthalmologic procedure, and outcome is typically measured by a single factor-improvement in visual acuity. Health related functional outcome testing, which quantifies patient's self-reported perception of impairment, can be integrated with objective clinical findings. Based on the patient's self-assessed lifestyle impairment, the physician and patient together can make an informed decision on the treatment that is most likely to benefit the patient. ^ A functional outcome test (the Houston Vision Assessment Test-Retina; HVAT-Retina) was developed and validated in patients with multiple retinal detachments in the same eye. The HVAT-Retina divides an estimated total impairment into subcomponents: contribution of visual disability (potentially correctable by retinal detachment surgery) and nonvisual physical disabilities (co-morbidities not affected by retinal detachment surgery. ^ Seventy-six patients participated in this prospective multicenter study. Seven patients were excluded from the analysis because they were not certain of their answers. Cronbach's alpha coefficient was 0.91 for presurgery HVAT-Retina and 0.94 post-surgery. The item-to-total correlation ranged from 0.50 to 0.88. Visual impairment score improved by 9 points from pre-surgery (p = 0.0003). Physical impairment score also improved from pre-surgery (p = 0.0002). ^ In conclusion, the results of this study demonstrate that the instrument is reliable and valid in patients presenting with recurrent retinal detachments. The HVAT-Retina is a simple instrument and does not burden the patient or the health professional in terms of time or cost. It may be self-administrated, not requiring an interviewer. Because the HVAT-Retina was designed to demonstrate outcomes perceivable by the patient, it has the potential to guide the decision making process between patient and physician. ^