3 resultados para Model evaluation
em DigitalCommons@The Texas Medical Center
Resumo:
Clinical medical librarianship is entering its second decade, but little evaluative data has accrued in the literature. Variations from the original programs and novel new approaches have insured the survival of the program so far. The clinical librarian (CL) forms a vital link between the library and the health care professional, operating as an important information transfer agent. However, to further insure the survival of these vital programs, hard evaluative evidence is needed. The University of Texas Medical Branch (UTMB) at Galveston began a CL Program in 1978/79. An extensive three-year pre/post evaluation study was conducted using a specifically developed evaluation model, which, if adopted by others, will provide the needed comparative data. Both a pilot study, or formative evaluation, and a summative evaluation were conducted. The results of this evaluation confirmed many of the conclusions reported by other CL programs. Eight hypotheses were proposed at the beginning of this study. Data were collected and used to support acceptance or rejection of the null hypotheses, and conclusions were drawn according to the results. Implications relevant to the study conclusions and future trends in medical librarianship are also discussed in the closing chapter.
Resumo:
Experience with anidulafungin against Candida krusei is limited. Immunosuppressed mice were injected with 1.3 x 10(7) to 1.5 x 10(7) CFU of C. krusei. Animals were treated with saline, 40 mg/kg fluconazole, 1 mg/kg amphotericin B, or 10 and 20 mg/kg anidulafungin for 5 days. Anidulafungin improved survival and significantly reduced the number of CFU/g in kidneys and serum beta-glucan levels.
Resumo:
With continuous new improvements in brachytherapy source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters to establish PRESAGE® as a suitable brachytherapy dosimeter. The new AgX100 125I seed model (Theragenics Corporation) was then characterized using PRESAGE® following the TG-43 protocol. PRESAGE® dosimeters are solid, polyurethane-based, 3D dosimeters doped with radiochromic leuco dyes that produce a linear optical density response to radiation dose. For this project, the radiochromic response in PRESAGE® was captured using optical-CT scanning (632 nm) and the final 3D dose matrix was reconstructed using the MATLAB software. An Amersham 6711 seed with an air-kerma strength of approximately 9 U was used to irradiate two dosimeters to 2 Gy and 11 Gy at 1 cm to evaluate dose rates in the r=1 cm to r=5 cm region. The dosimetry parameters were compared to the values published in the updated AAPM Report No. 51 (TG-43U1). An AgX100 seed with an air-kerma strength of about 6 U was used to irradiate two dosimeters to 3.6 Gy and 12.5 Gy at 1 cm. The dosimetry parameters for the AgX100 were compared to the values measured from previous Monte-Carlo and experimental studies. In general, the measured dose rate constant, anisotropy function, and radial dose function for the Amersham 6711 showed agreements better than 5% compared to consensus values in the r=1 to r=3 cm region. The dose rates and radial dose functions measured for the AgX100 agreed with the MCNPX and TLD-measured values within 3% in the r=1 to r=3 cm region. The measured anisotropy function in PRESAGE® showed relative differences of up to 9% with the MCNPX calculated values. It was determined that post-irradiation optical density change over several days was non-linear in different dose regions, and therefore the dose values in the r=4 to r=5 cm regions had higher uncertainty due to this effect. This study demonstrated that within the radial distance of 3 cm, brachytherapy dosimetry in PRESAGE® can be accurate within 5% as long as irradiation times are within 48 hours.