2 resultados para Method of multiple scale
em DigitalCommons@The Texas Medical Center
Resumo:
A two-pronged approach for the automatic quantitation of multiple sclerosis (MS) lesions on magnetic resonance (MR) images has been developed. This method includes the design and use of a pulse sequence for improved lesion-to-tissue contrast (LTC) and seeks to identify and minimize the sources of false lesion classifications in segmented images. The new pulse sequence, referred to as AFFIRMATIVE (Attenuation of Fluid by Fast Inversion Recovery with MAgnetization Transfer Imaging with Variable Echoes), improves the LTC, relative to spin-echo images, by combining Fluid-Attenuated Inversion Recovery (FLAIR) and Magnetization Transfer Contrast (MTC). In addition to acquiring fast FLAIR/MTC images, the AFFIRMATIVE sequence simultaneously acquires fast spin-echo (FSE) images for spatial registration of images, which is necessary for accurate lesion quantitation. Flow has been found to be a primary source of false lesion classifications. Therefore, an imaging protocol and reconstruction methods are developed to generate "flow images" which depict both coherent (vascular) and incoherent (CSF) flow. An automatic technique is designed for the removal of extra-meningeal tissues, since these are known to be sources of false lesion classifications. A retrospective, three-dimensional (3D) registration algorithm is implemented to correct for patient movement which may have occurred between AFFIRMATIVE and flow imaging scans. Following application of these pre-processing steps, images are segmented into white matter, gray matter, cerebrospinal fluid, and MS lesions based on AFFIRMATIVE and flow images using an automatic algorithm. All algorithms are seamlessly integrated into a single MR image analysis software package. Lesion quantitation has been performed on images from 15 patient volunteers. The total processing time is less than two hours per patient on a SPARCstation 20. The automated nature of this approach should provide an objective means of monitoring the progression, stabilization, and/or regression of MS lesions in large-scale, multi-center clinical trials. ^
Resumo:
The difficulty of detecting differential gene expression in microarray data has existed for many years. Several correction procedures try to avoid the family-wise error rate in multiple comparison process, including the Bonferroni and Sidak single-step p-value adjustments, Holm's step-down correction method, and Benjamini and Hochberg's false discovery rate (FDR) correction procedure. Each multiple comparison technique has its advantages and weaknesses. We studied each multiple comparison method through numerical studies (simulations) and applied the methods to the real exploratory DNA microarray data, which detect of molecular signatures in papillary thyroid cancer (PTC) patients. According to our results of simulation studies, Benjamini and Hochberg step-up FDR controlling procedure is the best process among these multiple comparison methods and we discovered 1277 potential biomarkers among 54675 probe sets after applying the Benjamini and Hochberg's method to PTC microarray data.^