17 resultados para Medical Monitoring
em DigitalCommons@The Texas Medical Center
Resumo:
Current toxic tort cases have increased national awareness of health concerns and present an important avenue in which public health scientists can perform a vital function: in litigation, and in public health initiatives and promotions which may result. This review presents a systematic approach, using the paradigm of interactive public health disciplines, for the design of a matrix framework for medical surveillance of workers exposed to toxic substances. The matrix framework design addresses the required scientific bases to support the legal remedy of medical monitoring for workers injured as a result of their exposure to toxic agents. A background of recent legal developments which have a direct impact on the use of scientific expertise in litigation is examined in the context of toxic exposure litigation and the attainment of public health goals. The matrix model is applied to five different workplace exposures: dental mercury, firefighting, vinyl chloride manufacture, radon in mining and silica. An exposure matrix designed by the Department of Energy for government nuclear workers is included as a reference comparison to the design matrix. ^
Resumo:
Utilizing advanced information technology, Intensive Care Unit (ICU) remote monitoring allows highly trained specialists to oversee a large number of patients at multiple sites on a continuous basis. In the current research, we conducted a time-motion study of registered nurses’ work in an ICU remote monitoring facility. Data were collected on seven nurses through 40 hours of observation. The results showed that nurses’ essential tasks were centered on three themes: monitoring patients, maintaining patients’ health records, and managing technology use. In monitoring patients, nurses spent 52% of the time assimilating information embedded in a clinical information system and 15% on monitoring live vitals. System-generated alerts frequently interrupted nurses in their task performance and redirected them to manage suddenly appearing events. These findings provide insight into nurses’ workflow in a new, technology-driven critical care setting and have important implications for system design, work engineering, and personnel selection and training.
Resumo:
Quantitative imaging with 18F-FDG PET/CT has the potential to provide an in vivo assessment of response to radiotherapy (RT). However, comparing tissue tracer uptake in longitudinal studies is often confounded by variations in patient setup and potential treatment induced gross anatomic changes. These variations make true response monitoring for the same anatomic volume a challenge, not only for tumors, but also for normal organs-at-risk (OAR). The central hypothesis of this study is that more accurate image registration will lead to improved quantitation of tissue response to RT with 18F-FDG PET/CT. Employing an in-house developed “demons” based deformable image registration algorithm, pre-RT tumor and parotid gland volumes can be more accurately mapped to serial functional images. To test the hypothesis, specific aim 1 was designed to analyze whether deformably mapping tumor volumes rather than aligning to bony structures leads to superior tumor response assessment. We found that deformable mapping of the most metabolically avid regions improved response prediction (P<0.05). The positive predictive power for residual disease was 63% compared to 50% for contrast enhanced post-RT CT. Specific aim 2 was designed to use parotid gland standardized uptake value (SUV) as an objective imaging biomarker for salivary toxicity. We found that relative change in parotid gland SUV correlated strongly with salivary toxicity as defined by the RTOG/EORTC late effects analytic scale (Spearman’s ρ = -0.96, P<0.01). Finally, the goal of specific aim 3 was to create a phenomenological dose-SUV response model for the human parotid glands. Utilizing only baseline metabolic function and the planned dose distribution, predicting parotid SUV change or salivary toxicity, based upon specific aim 2, became possible. We found that the predicted and observed parotid SUV relative changes were significantly correlated (Spearman’s ρ = 0.94, P<0.01). The application of deformable image registration to quantitative treatment response monitoring with 18F-FDG PET/CT could have a profound impact on patient management. Accurate and early identification of residual disease may allow for more timely intervention, while the ability to quantify and predict toxicity of normal OAR might permit individualized refinement of radiation treatment plan designs.
Resumo:
Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.
Devices in heart failure: potential methods for device-based monitoring of congestive heart failure.
Resumo:
Congestive heart failure has long been one of the most serious medical conditions in the United States; in fact, in the United States alone, heart failure accounts for 6.5 million days of hospitalization each year. One important goal of heart-failure therapy is to inhibit the progression of congestive heart failure through pharmacologic and device-based therapies. Therefore, there have been efforts to develop device-based therapies aimed at improving cardiac reserve and optimizing pump function to meet metabolic requirements. The course of congestive heart failure is often worsened by other conditions, including new-onset arrhythmias, ischemia and infarction, valvulopathy, decompensation, end-organ damage, and therapeutic refractoriness, that have an impact on outcomes. The onset of such conditions is sometimes heralded by subtle pathophysiologic changes, and the timely identification of these changes may promote the use of preventive measures. Consequently, device-based methods could in the future have an important role in the timely identification of the subtle pathophysiologic changes associated with congestive heart failure.
Resumo:
Intensive Family Preservation Services seek to reflect the values of focusing on client strengths and viewing clients as colleagues. To promote those values, Intensive Family Preservation Programs should include a systematic form of client self monitoring in their packages of outcome measures. This paper presents a model of idiographic self-monitoring used in time series, single system research design developed for Family Partners, a family preservation program of the School for Contemporary Education in Annandale, Virginia. The evaluation model provides a means of empowering client families to utilize their strengths and promote their status as colleague in determining their own goals, participating in the change process, and measuring their own progress.
Resumo:
The increased use of vancomycin in hospitals has resulted in a standard practice to monitor serum vancomycin levels because of possible nephrotoxicity. However, the routine monitoring of vancomycin serum concentration is under criticism and the cost effectiveness of such routine monitoring is in question because frequent monitoring neither results in increase efficacy nor decrease nephrotoxicity. The purpose of the present study is to determine factors that may place patients at increased risk of developing vancomycin induced nephrotoxicity and for whom monitoring may be most beneficial.^ From September to December 1992, 752 consecutive in patients at The University of Texas M. D. Anderson Cancer Center, Houston, were prospectively evaluated for nephrotoxicity in order to describe predictive risk factors for developing vancomycin related nephrotoxicity. Ninety-five patients (13 percent) developed nephrotoxicity. A total of 299 patients (40 percent) were considered monitored (vancomycin serum levels determined during the course of therapy), and 346 patients (46 percent) were receiving concurrent moderate to highly nephrotoxic drugs.^ Factors that were found to be significantly associated with nephrotoxicity in univariate analysis were: gender, base serum creatinine greater than 1.5mg/dl, monitor, leukemia, concurrent moderate to highly nephrotoxic drugs, and APACHE III scores of 40 or more. Significant factors in the univariate analysis were then entered into a stepwise logistic regression analysis to determine independent predictive risk factors for vancomycin induced nephrotoxicity.^ Factors, with their corresponding odds ratios and 95% confidence limits, selected by stepwise logistic regression analysis to be predictive of vancomycin induced nephrotoxicity were: Concurrent therapy with moderate to highly nephrotoxic drugs (2.89; 1.76-4.74), APACHE III scores of 40 or more (1.98; 1.16-3.38), and male gender (1.98; 1.04-2.71).^ Subgroup (monitor and non-monitor) analysis showed that male (OR = 1.87; 95% CI = 1.01, 3.45) and moderate to highly nephrotoxic drugs (OR = 4.58; 95% CI = 2.11, 9.94) were significant for nephrotoxicity in monitored patients. However, only APACHE III score (OR = 2.67; 95% CI = 1.13,6.29) was significant for nephrotoxicity in non-monitored patients.^ The conclusion drawn from this study is that not every patient receiving vancomycin therapy needs frequent monitoring of vancomycin serum levels. Such routine monitoring may be appropriate in patients with one or more of the identified risk factors and low risk patients do not need to be subjected to the discomfort and added cost of multiple blood sampling. Such prudent selection of patients to monitor may decrease cost to patients and hospital. ^
Does parental monitoring influence the use of alcohol and drugs among inner city 7th grade students?
Resumo:
Objective. To examine associations between parental monitoring and adolescent alcohol/drug use. ^ Methods. 981 7th grade students from 10 inner-city middle schools were surveyed at the 3 month follow-up of an HIV, STD, and pregnancy prevention program. Data from 549 control subjects were used for analyses. Multinomial logistic regression was used to examine associations between five parental monitoring variables and substance use, coded as: low risk [never drank alcohol or used drugs (0)], moderate risk [drank alcohol, no drug use (1)], and high risk [both drank alcohol and used drugs or just used drugs (2)]. ^ Results. Participants were 58.3% female, 39.6% African American, 43.8% Hispanic, mean age 13.3 years. Lifetime alcohol use was 47.9%. Lifetime drug use was 14.9%. Adjusted for gender, age, race, and family structure, each individual parental monitoring variable (perceived parental monitoring, less permissive parental monitoring, greater supervision (public places), greater supervision (teen clubs), and less time spent with older teens) was significant and protective for the moderate and high risk groups. When all 5 variables were entered into a single model, only perceived parental monitoring was significantly associated (OR=0.40, 95% CI 0.29-0.55) for the moderate risk group. For the high risk group, 3 variables were significantly protective (perceived parental monitoring OR=0.28, CI 0.18-0.42, less time spent with older teens OR=0.75, CI 0.60-0.93, and greater supervision (public places) OR=0.79, CI 0.64-0.99). ^ Conclusion. The association between parental monitoring and substance abuse is complex and varied for different risk levels. Implications for intervention development are addressed. ^
Resumo:
Very few studies have described MUP-1 concentrations and measured prevalence of Laboratory Animal Allergy (LAA) at such a diverse institution as the private medical school (MS) that is the focus of this study. Air sampling was performed in three dissimilar animal research facilities at MS and quantitated using a commercially available ELISA. Descriptive data was obtained from an anonymous laboratory animal allergy survey given to both animal facility employees and the researchers who utilize these facilities alike. Logistic regression analysis was then implemented to investigate specific factors that may be predictive of developing LAA as well as factors influencing the reporting of LAA symptoms to the occupational health program. Concentrations of MUP-1 detected ranged from below detectable levels (BDL) to a peak of 22.64 ng/m3 . Overall, 68 employees with symptoms claimed they improved while away from work and only 25 employees reported their symptoms to occupational health. Being Vietnamese, a smoker, not wearing a mask, and working in any facility longer than one year were all significant predictors of having LAA symptoms. This study suggests a LAA monitoring system that relies on self-reporting can be inadequate in estimating LAA problems. In addition, efforts need to be made to target training and educational materials for non-native English speaking employees to overcome language and cultural barriers and address their specific needs. ^
Resumo:
The Houston region is home to arguably the largest petrochemical and refining complex anywhere. The effluent of this complex includes many potentially hazardous compounds. Study of some of these compounds has led to recognition that a number of known and probable carcinogens are at elevated levels in ambient air. Two of these, benzene and 1,3-butadiene, have been found in concentrations which may pose health risk for residents of Houston.^ Recent popular journalism and publications by local research institutions has increased the interest of the public in Houston's air quality. Much of the literature has been critical of local regulatory agencies' oversight of industrial pollution. A number of citizens in the region have begun to volunteer with air quality advocacy groups in the testing of community air. Inexpensive methods exist for monitoring of ozone, particulate matter and airborne toxic ambient concentrations. This study is an evaluation of a technique that has been successfully applied to airborne toxics.^ This technique, solid phase microextraction (SPME), has been used to measure airborne volatile organic hydrocarbons at community-level concentrations. It is has yielded accurate and rapid concentration estimates at a relatively low cost per sample. Examples of its application to measurement of airborne benzene exist in the literature. None have been found for airborne 1,3-butadiene. These compounds were selected for an evaluation of SPME as a community-deployed technique, to replicate previous application to benzene, to expand application to 1,3-butadiene and due to the salience of these compounds in this community. ^ This study demonstrates that SPME is a useful technique for quantification of 1,3-butadiene at concentrations observed in Houston. Laboratory background levels precluded recommendation of the technique for benzene. One type of SPME fiber, 85 μm Carboxen/PDMS, was found to be a sensitive sampling device for 1,3-butadiene under temperature and humidity conditions common in Houston. This study indicates that these variables affect instrument response. This suggests the necessity of calibration within specific conditions of these variables. While deployment of this technique was less expensive than other methods of quantification of 1,3-butadiene, the complexity of calibration may exclude an SPME method from broad deployment by community groups.^
Resumo:
The potential for the direct analysis of enzyme reactions by fast atom bombardment (FAB) mass spectrometry has been investigated. Conditions are presented for the maintenance of enzymatic activity under FAB conditions along with FAB mass spectrometric data showing that these conditions can be applied to solutions of enzyme and substrate to follow enzymatic reactions inside the mass spectrometer in real-time. In addition, enzyme kinetic behavior under FAB mass spectrometric conditions is characterized using trypsin and its assay substrate, TAME, as an enzyme-substrate reaction model. These results show that two monitoring methods can be utilized to follow reactions by FAB mass spectrometry. The advantages of each method are discussed and illustrated by obtaining kinetic parameters from the direct analysis of enzyme reactions with assay or peptide substrates. ^
Resumo:
Previous research has shown dietary intake self-monitoring, and culturally tailored weight loss interventions to be effective tools for weight loss. Technology can be used to tailor weight loss interventions to better suit adolescents. There is a lack of research to date on the use of personal digital assistants (PDAs) to self-monitor dietary intake among adolescents. The objective of this study was to determine the difference in dietary intake self-monitoring frequency between using a Personal Digital Assistant (PDA) or paper logs as a diet diary in obese adolescent females; and to describe differences in diet adherence, as well as changes in body size and self-efficacy to resist eating. We hypothesized dietary intake self-monitoring frequency would be greater during PDA use than during paper log use. This study was a randomized crossover trial. Participants recorded their diet for 4 weeks: 2 weeks on a PDA and 2 weeks on paper logs. Thirty-four obese females ages 12-20 were recruited for participation. Thirty were included in analyses. Participants recorded more entries/day while using the paper logs (4.10 entries/day ± 0.63) than while using the PDA (3.01 entries/day ±0.75) (p<0.001). Significantly more meals and snacks were skipped during paper log use (0.81/day ± 0.65) than during PDA use (0.23/day ± 0.22) (p=0.011). Changes in body size (BMI, weight, and waist circumference) and self-efficacy to resist eating did not differ significantly between PDA and paper log use. When compared to paper logs, participants felt the PDA was more convenient (p=0.020), looked forward to using the PDA more (p=0.008), and would rather continue using the PDA than the paper logs (p=0.020). The findings of this study indicate use of a PDA as a dietary intake self-monitoring tool among adolescents would not result in increased dietary intake self-monitoring to aid in weight loss. Use of paper logs would result in greater data returned to clinicians, though use of PDAs would likely get adolescents more excited about adhering to recommendations to record their diet. Future research should look at updated communication devices, such as cell phones and other PDAs with additional features, and the role they can play in increasing dietary intake self-monitoring among adolescents.^
Resumo:
This study (1) established comedogenicity dose response curves for the pure compounds of 3,3$\sp\prime$,4,4$\sp\prime$-tetrachloroazobenzene (TCAB) and 3,3$\sp\prime$,4,4$\sp\prime$-tetrachloroazoxybenzene (TCAOB) individually and as a couple-compound using a rabbit ear model; (2) used a rabbit ear model to establish comedogenicity potential for TCAB and TCAOB as they existed in a given industrial herbicide manufacture process; (3) evaluated actual environmental contamination in a herbicide industrial setting by air monitoring and wipe sampling; (4) biologically monitored potentially exposed workers for alterations in follicular orifice size as an index of actual exposure to chloracnegenic compounds; and (5) biologically monitored potentially exposed workers for changes in weight, cholesterol, triglycerides and blood sugar.^ A silastic monomer mold (an objective measure) was used to measure change in follicular orifice size over time. This required taking impressions of (1) skin of the forehead and right and left malar crescents of workers and (2) the skin of the external ear of the rabbit. Molds were stained using a solution of hematoxylin and digitized using a Nikon UFX microscope (magnification 300 X), a drawing tube and a digitizing tablet attached to an IBM Personal Computer. Comedogenicity assays were used to establish dose-response curves for TCAB, TCAOB and the couple-compound TCAB + TCAOB.^ No evidence of chloracne or toxicity was observed in any of the workers. Nor, was there a statistically significant increase in size of follicular orifice means measured over time. This was attributed to extensive personal and environmental hygiene programs along with teaching the workers about chloracne, its cause and its prevention. These programs may have been the greatest factor in preventing the development of chloracne in this group of workers. Monitoring of the plant environment showed relatively high concentrations of the couple-compound (TCAB + TCAOB). Comedogenicity assays showed a linear dose-response relationship over time for TCAB, TCAOB and the couple-compound. An antagonistic action was found for the TCAB/TCAOB of the couple-compound; such action may provide some protection to workers in this type of setting. It is speculated that the observed antagonistic action may be due to the difference in binding affinities of TCAB/TCAOB for receptor sites. ^
Resumo:
A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using $\alpha$/$\beta$ discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen.^ U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-$\ell$ aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi $\ell\sp{-1}$. $\alpha$-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi $\ell\sp-1$ are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain $\sp{234}$U/$\sp{238}$U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation.^ The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross $\alpha$ activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi $\ell\sp{-1}$, with seven samples exceeding the proposed Maximum Contaminant Level of 20 $\mu$g $\ell\sp{-1}$. Four exceeded the proposed activity screening level of 30 pCi $\ell\sp{-1}$. Isotopic ratios ranged from 0.87 to 41.8, while one sample contained $\sp{234}$U activity of 34.6 pCi $\ell\sp{-1}$ in the complete absence of its parent, $\sp{238}$U. U mass in the samples with elevated activity ranged from 0.0 to 103 $\mu$g $\ell\sp{-1}$. A limited test of screening surface and groundwaters for contamination by U from waste sites and natural processes was also successful. ^