8 resultados para Manufacturers

em DigitalCommons@The Texas Medical Center


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine the effects of contamination with smoker's and non-smoker's saliva on the bond strength of resin composite to superficial dentin using different adhesive systems. The interfacial structure between the resin and dentin was evaluated for each treatment using environmental scanning electron microscopy (ESEM). Freshly extracted human molars were ground with 600-grit SiC paper to expose the superficial dentin. Adhesives [One-Up-Bond-F-Plus (OUFP) and Adper-Prompt-L-Pop (APLP)] and resin composite (TPHSpectrum) were bonded to the dentin (n = 8/group, 180 total specimens) under five surface conditions: control (adhesive applied following manufacturers' instructions); saliva, then 5-s air dry, then adhesive; adhesive, saliva, 5-s air dry; adhesive, saliva, 5-s water rinse, 5-s air dry (ASW group); and adhesive, saliva, 5-s water rinse, 5-s air dry, reapply adhesive (ASWA group). After storage in water at 37 degrees C for 24 h, the specimens were debonded under tension at a speed of 0.5 mm/min. ESEM photomicrographs of the dentin/adhesive interfaces were taken. Mean bond strength ranged from 8.1 to 24.1 MPa. Fisher's protected least significant difference (P = 0.05) intervals for critical adhesive, saliva, and surface condition differences were 1.3, 1.3, and 2.1 MPa, respectively. There were no significant differences in bond strength to dentin between contamination by smoker's and nonsmoker's saliva, but bond strengths were significantly different between adhesive systems, with OUFP twice as strong as APLP under almost all conditions. After adhesive application and contamination with either smoker's or nonsmoker's saliva followed by washing and reapplication of the adhesive (ASWA group), the bond strength of both adhesive systems was the same as that of the control group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study assessed if hospital-wide implementation of a needleless intravenous connection system reduces the number of reported percutaneous injuries, overall and those specifically due to intravenous connection activities.^ Incidence rates were compared before and after hospital-wide implementation of a needleless intravenous system at two hospitals, a full service general hospital and a pediatric hospital. The years 1989-1991 were designated as pre-implementation and 1993 was designated as post-implementation. Data from 1992 were not included in the effectiveness evaluation to allow employees to become familiar with use of the new device. The two hospitals showed rate ratios of 1.37 (95% CI = 1.22-1.54, p $\le$.0001) and 1.63 (95% CI = 1.34-1.97, p $\le$.0001), or a 27.1% and a 38.6% reduction in overall injury rate, respectively. Rate ratios for intravenous connection injuries were 2.67 (95% CI = 1.89-3.78, p $\le$.0001) and 3.35 (95% CI = 1.87-6.02, p $\le$.0001), or a 62.5% and a 69.9% reduction in injury rate, respectively. Rate ratios for all non-intravenous connection injuries were calculated to control for factors other than device implementation that may have been operating to reduce the injury rate. These rate ratios were lower, 1.21 and 1.44, demonstrating the magnitude of injury reduction due to factors other than device implementation. It was concluded that the device was effective in reduction of numbers of reported percutaneous injuries.^ Use-effectiveness of the system was also assessed by a survey of randomly selected device users to determine satisfaction with the device, frequency of use and barriers to use. Four hundred seventy-eight surveys were returned for a response rate of 50.9%. Approximately 94% of respondents at both hospitals expressed satisfaction with the needleless system and recommended continued use. The survey also revealed that even though over 50% of respondents report using the device "always" or "most of the time" for intravenous medication administration, flushing lines, and connecting secondary intravenous lines, needles were still being used for these same activities. Compatibility, accessibility and other technical problems were reported as reasons for using needles for these activities. These problems must be addressed, by both manufacturers and users, before the needleless system will be effective in prevention of all intravenous connection injuries. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Food and Drug Administration (FDA) is responsible for risk assessment and risk management in the post-market surveillance of the U.S. medical device industry. One of the FDA regulatory mechanisms, the Medical Device Reporting System (MDR) is an adverse event reporting system intended to provide the FDA with advance warning of device problems. It includes voluntary reporting for individuals, and mandatory reporting for device manufacturers. ^ In a study of alleged breast implant safety problems, this research examines the organizational processes by which the FDA gathers data on adverse events and uses adverse event reporting systems to assess and manage risk. The research reviews the literature on problem recognition, risk perception, and organizational learning to understand the influence highly publicized events may have on adverse event reporting. Understanding the influence of an environmental factor, such as publicity, on adverse event reporting can provide insight into the question of whether the FDA's adverse event reporting system operates as an early warning system for medical device problems. ^ The research focuses on two main questions. The first question addresses the relationship between publicity and the voluntary and mandatory reporting of adverse events. The second question examines whether government agencies make use of these adverse event reports. ^ Using quantitative and qualitative methods, a longitudinal study was conducted of the number and content of adverse event reports regarding breast implants filed with the FDA's medical device reporting system during 1985–1991. To assess variation in publicity over time, the print media were analyzed to identify articles related to breast implant failures. ^ The exploratory findings suggest that an increase in media activity is related to an increase in voluntary reporting, especially following periods of intense media coverage of the FDA. However, a similar relationship was not found between media activity and manufacturers' mandatory adverse event reporting. A review of government committee and agency reports on the FDA published during 1976–1996 produced little evidence to suggest that publicity or MDR information contributed to problem recognition, agenda setting, or the formulation of policy recommendations. ^ The research findings suggest that the reporting of breast implant problems to FDA may reflect the perceptions and concerns of the reporting groups, a barometer of the volume and content of media attention. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Childhood overweight and obesity are two major public health problems that are of economic and medical concern in the world today (Lobstein, Baur, & Uauy, 2004). Overweight conditions in childhood are important because they are widely prevalent, serious, and carry lifetime consequences for health and well being (Lobstein et al., 2004). Several studies have shown an association between television viewing and obesity in all age groups (Caroli, Argentieri, Cardone, & Masi, 2004; Harper, 2006; Vandewater & Huang, 2006; Wiecha et al., 2006). One mechanism that potentially links television viewing to childhood obesity is food advertising (Story, 2003). ^ The purpose of this study was to examine the types of foods advertised on children's television programming and to determine if there have been any changes in the number and types of commercials over the last 13 years. In addition, the food content of the advertisements was compared to the 2005 Dietary Guidelines to determine if the foods targeted were consistent with the current recommendations. Finally, each television network was analyzed individually to determine any differences between advertising on cable and regular programming. ^ A descriptive analysis was conducted on the most commonly advertised commercials during children's television programming on Saturday morning from 7 a.m. to 10:30 a.m. A total of 10 major television networks were viewed on three different Saturday mornings during June and July 2007. Commercial advertising accounted for approximately 19% of children's total viewing time. Of the 3,185 commercials, 28.5% were for foods, 67.7% were for non-food items, and 3.8% were PSAs. On average, there were 30 commercial advertisements and PSAs per hour, of which approximately nine were for food. ^ Of the 907 food advertisements, 72.0% were for foods classified in the fats, oils, and sugar group. The next largest group (17.3%) was for restaurant food of which 15.3% were for unhealthy/fast food restaurant fare. The most frequently advertised food product on Saturday morning television was regular cereal, accounting for 43.9% of all food advertisements. ^ Cable and regular programming stations varied slightly in the amount, length, and category of commercials. Cable television had about 50% less commercials and PSAs (1098) than regular programming (2087), but only had approximately 150 minutes less total commercial and PSA time; therefore, cable, in general, had longer commercials than regular programming. Overall, cable programming had more advertisements encouraging increased physical activity and positive nutrition behavior with less commercials focusing on the fats, oils, and sugar groups, compared to regular programming. ^ During the last 13 years, food advertisements have not improved, despite the recent IOM report on marketing foods to children (Institute of Medicine-Committee on Food Marketing and the Diets of Children and Youth, 2005), although the frequency of food advertisements has improved slightly. Children are now viewing an average of one food advertisement every 7 minutes, compared to one food advertisement every 5 minutes in 1994 (Kotz & Story, 1994). Therefore, manufacturers are putting a greater emphasis on advertising other products to children. Despite the recent attention to the issue of marketing unhealthy foods to children through television advertisements, not much progress has been noted since 1994. Further advocacy and regulatory issues concerning the content of advertisements during Saturday morning TV need to be explored. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Surgeon General recommends preschoolers 3-5 years old accumulate 60 minutes of moderate-to-vigorous physical activity (MVPA) per day. However, there is limited data measuring physical activity (PA) and MVPA amongst this population. The purpose of this cross-sectional study is to determine the validity, reliability, and feasibility of using MVP 4 Function Walk4Life digital pedometers (MVP-4) in measuring MVPA among preschoolers using the newly modified direct observational technique, System for Observing Fitness Instruction Time-Preschool Version (SOFIT-P) as the gold standard. An ethnically diverse population of 3-5 year old underserved children were recruited from two Harris County Department of Education (HCDE) Head Start centers. For 2 days at baseline and 2 days at post-test, 75 children enrolled wore MVP-4 pedometers for approximately 6-hours per observation day and were observed using SOFIT-P during predominantly active times. Statistical analyses used Pearson "r" correlation coefficients to determine mean minutes of PA and MVPA, convergent and criterion validity, and reliability. Significance was set at p = <0.05. Feasibility was determined through process evaluation information collected during this study via observations from data collectors and teacher input. Results show mean minutes of PA and MVPA ranged between 30-42 and 11-14 minutes, respectively. Convergent validity comparing BMI percentiles with MVP-4 PA outcomes show no significance at pre-test; however, each measurement at post-test showed significance for MVPA (p = 0.0247, p = 0.0056), respectively. Criterion validity comparing percent MVPA time between SOFIT-P and MVP-4 pedometers was determined; however, results deemed insufficient due to inconsistency in observation times while using the newly developed SOFIT-P. Reliability measures show no significance at pre-test, yet show significant results for all PA outcomes at post-test (p = 0.001, p = 0.001, p = 0.0010, p = 0.003), respectively. Finally, MVP-4 pedometers lacked feasibility due to logistical barriers in design. Researchers feel the significant results at post-test are secondary to increased familiarity and more accurate placement of pedometers across time. Researchers suggest manufacturers of MVP-4 pedometers further modify the instrument for ease of use with this population, following which future studies ought to determine validity using objective measures or all-day direct observation techniques.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. HPV is the underlying cause of cervical cancer, a malignant tumor of the female genital tract. Each year, cervical cancer is newly diagnosed in approximately 10,000 women, and over 3,000 women die from the malignancy. In addition, HPV is implicated as a cause of other cancers involving the genital tract, male and female, and the head and neck. ^ Gardasil, a vaccine against HPV, was licensed by the FDA in June 2006. Early study results have shown Gardasil to be safe and effective at preventing HPV infections that are commonly associated with the development of cervical cancer, as well as other HPV-related cancers and genital warts. The vaccine is most effective when administered in childhood, before initial exposure to HPV, which typically occurs shortly after the onset of sexual activity. Accordingly, the CDC's Advisory Committee on Immunization Practices (ACIP) has recommended routine vaccination of females aged 11-12 years. ^ Taking the ACIP recommendation one step further, many states have considered school-based mandates of the HPV vaccine in an attempt to reduce the burden of HPV-related illness, in particular to reduce the disparately high incidence of cervical cancer in medically underserved populations. These mandate attempts have sparked heated debate—highlighting public concerns regarding adolescent sexuality, corporate greed, and vaccines in general. ^ Methods. My research focuses on publicly available sources of information such as medical journals, government reports (federal and state), NGO reports, newspapers, and books. I begin with a background discussion of HPV, cervical cancer, and the HPV vaccine. I then discuss public health policy issues related to vaccines, vaccine mandates, and HPV-related illness. Specifically, I discuss the public health benefit of previous vaccine mandates, the legality of vaccine mandates, and the undue corporate influence on the politics of instituting HPV vaccine mandates. In addition, I examine some of the causes behind the anti-vaccine movement and the controversy surrounding adolescent sexuality as it pertains to the HPV vaccine. In the final section, I focus on the recent failed attempt by Governor Rick Perry to mandate the HPV vaccine in Texas. A retrospective analysis of Governor Perry's policy decisions is undertaken and recommendations are made regarding future attempts to mandate the HPV vaccine, or other vaccines under development for similar sexually transmitted viral diseases such as HIV and herpes simplex. ^ Results. In Texas, as in other states across the country, HPV vaccine mandates faced opposition from those who, while they may support mandates of other vaccines, oppose mandates for the HPV vaccine based largely on the idea that HPV is a sexually transmitted disease—they see responsible sexual behavior as the appropriate method for preventing HPV-related illness. A second major group of opposition comes from those who are generally opposed to all vaccine mandates, due to concerns that mandates are intended primarily for the financial benefit of the pharmaceutical industry or due to concerns—largely unfounded—that vaccines pose a greater health threat than the illnesses they are designed to prevent. ^ Conclusion. In order to reduce opposition to vaccine mandates, care must be taken to educate the public regarding the benefits of vaccination by mobilizing the public health sector, avoid the impression that the decision to institute mandates is rash or pressured by allowing time for open debate, and minimize lobbying efforts by vaccine manufacturers. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial pathogens such as enterotoxigenic Escherichia coli, Salmonella, and Campylobacter spp. are associated with up to 80% of diarrheal illness to travelers from developed countries to developing countries. In order to study acute gastrointestinal diseases, researchers from developed countries such as the United States rely on transporting clinical specimens from the developing countries to laboratories in the U.S. in transport media systems. There are few commercially available transport media systems cited in the literature or designated by transport system manufacturers for the transport of enteric bacteria. Therefore a laboratory-based study was conducted to assess three commercial available transport media systems, two gel swabs and one liquid vial, to determine the most appropriate for the maintenance and recovery of common enteric bacterial pathogens. A total of 13 bacterial enteropathogens were recovered from 25°C and 4°C storage temperatures at time points up to 21 days. The results demonstrated that the gel swab and liquid vial transport systems performed similarly for all isolates at both temperatures. All three transport media systems struggled to maintain the isolates at recoverable concentrations when stored at 4°C and it is recommended that isolates be stored at 25°C in transport media systems. Lastly, swab transport systems are recommend for transport since they are small and easy to pack, resist leakage, and are less expensive than similarly performing liquid vial transport media systems.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electronic waste is a fairly new and largely unknown phenomenon. Accordingly, governments have only recently acknowledged electronic waste as a threat to the environment and public health. In attempting to mitigate the hazards associated with this rapidly growing toxic waste stream, governments at all levels have started to implement e-waste management programs. The legislation enacted to create these programs is based on extended producer responsibility or EPR policy. ^ EPR shifts the burden of final disposal of e-waste from the consumer or municipal solid waste system to the manufacturer of electronic equipment. Applying an EPR policy is intended to send signals up the production chain to the manufacturer. The desired outcome is to change the methods of production in order to reduce production outputs/inputs with the ultimate goal of changing product design. This thesis performs a policy analysis of the current e-waste policies at the federal and state level of government, focusing specifically on Texas e-waste policies. ^ The Texas e-waste law known, as HB 2714 or the Texas Computer TakeBack Law, requires manufacturers to provide individual consumers with a free and convenient method for returning their used computers to manufacturers. The law is based on individual producer responsibility and shared responsibility among consumer, retailers, recyclers, and the TCEQ. ^ Using a set of evaluation criteria created by the Organization for Economic Co-operation and Development, the Texas e-waste law was examined to determine its effectiveness at reducing the threat of e-waste in Texas. Based on the outcomes of the analysis certain recommendations were made for the legislature to incorporate into HB 2714. ^ The results of the policy analysis show that HB 2714 is a poorly constructed law and does not provide the desired results seen in other states with EPR policies. The TakeBack Law does little to change the collection methods of manufacturers and even less to change their production habits. If the e-waste problem is to be taken seriously, HB 2714 must be amended to reflect the proposed changes in this thesis.^