4 resultados para Least limiting water range
em DigitalCommons@The Texas Medical Center
Resumo:
Purpose: The rapid distal falloff of a proton beam allows for sparing of normal tissues distal to the target. However proton beams that aim directly towards critical structures are avoided due to concerns of range uncertainties, such as CT number conversion and anatomy variations. We propose to eliminate range uncertainty and enable prostate treatment with a single anterior beam by detecting the proton’s range at the prostate-rectal interface and adaptively adjusting the range in vivo and in real-time. Materials and Methods: A prototype device, consisting of an endorectal liquid scintillation detector and dual-inverted Lucite wedges for range compensation, was designed to test the feasibility and accuracy of the technique. Liquid scintillation filled volume was fitted with optical fiber and placed inside the rectum of an anthropomorphic pelvic phantom. Photodiode-generated current signal was generated as a function of proton beam distal depth, and the spatial resolution of this technique was calculated by relating the variance in detecting proton spills to its maximum penetration depth. The relative water-equivalent thickness of the wedges was measured in a water phantom and prospectively tested to determine the accuracy of range corrections. Treatment simulation studies were performed to test the potential dosimetric benefit in sparing the rectum. Results: The spatial resolution of the detector in phantom measurement was 0.5 mm. The precision of the range correction was 0.04 mm. The residual margin to ensure CTV coverage was 1.1 mm. The composite distal margin for 95% treatment confidence was 2.4 mm. Planning studies based on a previously estimated 2mm margin (90% treatment confidence) for 27 patients showed a rectal sparing up to 51% at 70 Gy and 57% at 40 Gy relative to IMRT and bilateral proton treatment. Conclusion: We demonstrated the feasibility of our design. Use of this technique allows for proton treatment using a single anterior beam, significantly reducing the rectal dose.
Resumo:
Leukopenia, the leukocyte count, and prognosis of disease are interrelated; a systematic search of the literature was undertaken to ascertain the strength of the evidence. One hundred seventy-one studies were found from 1953 onward pertaining to the predictive capabilities of the leukocyte count. Of those studies, 42 met inclusion criteria. An estimated range of 2,200cells/μL to 7,000cells/μL was determined as that which indicates good prognosis in disease and indicates the least amount of risk to an individual overall. Tables of the evidence are included indicating the disparate populations examined and the possible degree of association. ^
Resumo:
Background. Diarrhea and malnutrition are the leading causes of mortality for children age one to four in the Dominican Republic. Communities within the Miches watershed lack sanitation infrastructure and water purification systems, which increases the risk of exposure to water-borne pathogens. The purpose of this cross-sectional study was to analyze health information gathered through household interviews and to test water samples for the presence of diarrheagenic pathogens and antibiotic-resistant bacteria within the Miches watershed. Methods. Frequency counts and thematic analysis were used to investigate Human Health Survey responses and Fisher's exact test was used to determine correlation between water source and reported illness. Bacteria cultured from water samples were analyzed by Gram stain, real-time PCR, API® 20E biochemical identification, and for antibiotic resistance. Results. Community members reported concerns about water sources with respect to water quality, availability, and environmental contamination. Pathogenic strains of E. coli were present in the water samples. Drinking aquifer water was positively-correlated with reported stomach aches (p=0.04) while drinking from rivers or creeks was associated with the reported absence of “gripe” (cold or flu) (p=0.01). The lack of association between reported illnesses and water source for the majority of variables suggested that there were multiple vehicles of disease transmission. Antibiotic resistant bacteria were isolated from the water samples tested. Conclusions. The presence of pathogenic E. coli in water samples suggested that water is at least one route of transmission for diarrheagenic pathogens in the Miches watershed. The presence of antibiotic-resistant bacteria in the water samples may indicate the proliferation of resistance plasmids in the environment as a result of antibiotic overuse in human and animal populations and a lack of sanitation infrastructure. An intervention that targets areas of hygiene, sanitation, and water purification is recommended to limit human exposure to diarrheagenic pathogens and antibiotic-resistant organisms. ^
Resumo:
Developing countries are heavily burdened by limited access to safe drinking water and subsequent water-related diseases. Numerous water treatment interventions combat this public health crisis, encompassing both traditional and less-common methods. Of these, water disinfection serves as an important means to provide safe drinking water. Existing literature discusses a wide range of traditional treatment options and encourages the use of multi-barrier approaches including coagulation-flocculation, filtration, and disinfection. Most sources do not delve into approaches specifically appropriate for developing countries, nor do they exclusively examine water disinfection methods.^ The objective of this review is to focus on an extensive range of chemical, physio-chemical, and physical water disinfection techniques to provide a compilation, description and evaluation of options available. Such an objective provides further understanding and knowledge to better inform water treatment interventions and explores alternate means of water disinfection appropriate for developing countries. Appropriateness for developing countries corresponds to the effectiveness of an available, easy to use disinfection technique at providing safe drinking water at a low cost.^ Among chemical disinfectants, SWS sodium hypochlorite solution is preferred over sodium hypochlorite bleach due to consistent concentrations. Tablet forms are highly recommended chemical disinfectants because they are effective and very easy to use, but also because they are stable. Examples include sodium dichloroisocyanurate, calcium hypochlorite, and chlorine dioxide, which vary in cost depending on location and availability. Among physio-chemical disinfection options, electrolysis which produces mixed oxidants (MIOX) provides a highly effective disinfection option with a higher upfront cost but very low cost over the long term. Among physical disinfection options, solar disinfection (SODIS) applications are effective, but they treat only a fixed volume of water at a time. They come with higher initial costs but very low on-going costs. Additional effective disinfection techniques may be suitable depending on the location, availability and cost.^