2 resultados para Intravenous self-administration
em DigitalCommons@The Texas Medical Center
Resumo:
The purpose of this study was to examine factors that may be associated with benzodiazepine (BZ) self-administration and risks of dependence in anxious patients. Preliminary work included examination of psychosocial characteristics and subjective drug response as potential predictors of medication use. Fifty-five M, F patients with generalized anxiety or panic disorder participated in a 3-week outpatient Choice Procedure in which they self-medicated “as needed” with alprazolam (Alz) and placebo. Findings showed that a large amount of variance in alprazolam preference, frequency, and quantity of use could be predicted by measures of anxiety, drug liking, and certain personality characteristics. The primary study extended this work by examining whether individual differences in Alz sensitivity also predict patterns of use. Twenty anxious patients participated in the study, which required 11 weekly clinic visits. Ten of these also participated in a baseline assessment of HPA-axis function that involved 24-hour monitoring of cortisol and ACTH levels and a CRH Stimulation Test. This assessment was conducted on the basis of prior evidence that steroid metabolites exert neuromodulatory effects on the GABA A receptor and that HPA-axis function may be related to BZ sensitivity and long-term disability in anxious patients. Patients were classified as either HIGH or LOW users based on their p.r.n. patterns of Alz use during the first 3 weeks of the study. They then participated in a 4-week dose response trial in which they received prescribed doses of medication (placebo, 0.25, 0.5, and 1.0mg Alz), each taken TID for 1 week. The dose response trial was followed by a second 3-week Choice Procedure. Findings were not indicative of biological differences in Alz sensitivity between the HIGH and LOW users. However, the HIGH users had higher baseline anxiety and greater anxiolytic response to Alz than the LOW users. Anxiolytic benefits of p.r.n. and prescribed dosing were shown to be comparable, and patients' conservative patterns of p.r.n. medication use were not affected by the period of prescribed dosing. Although there was not strong evidence to suggest relationships between HPA-axis function and Alz use or sensitivity, interesting findings emerged about the relationship between HPA-axis function and anxiety. ^
Resumo:
This study assessed if hospital-wide implementation of a needleless intravenous connection system reduces the number of reported percutaneous injuries, overall and those specifically due to intravenous connection activities.^ Incidence rates were compared before and after hospital-wide implementation of a needleless intravenous system at two hospitals, a full service general hospital and a pediatric hospital. The years 1989-1991 were designated as pre-implementation and 1993 was designated as post-implementation. Data from 1992 were not included in the effectiveness evaluation to allow employees to become familiar with use of the new device. The two hospitals showed rate ratios of 1.37 (95% CI = 1.22-1.54, p $\le$.0001) and 1.63 (95% CI = 1.34-1.97, p $\le$.0001), or a 27.1% and a 38.6% reduction in overall injury rate, respectively. Rate ratios for intravenous connection injuries were 2.67 (95% CI = 1.89-3.78, p $\le$.0001) and 3.35 (95% CI = 1.87-6.02, p $\le$.0001), or a 62.5% and a 69.9% reduction in injury rate, respectively. Rate ratios for all non-intravenous connection injuries were calculated to control for factors other than device implementation that may have been operating to reduce the injury rate. These rate ratios were lower, 1.21 and 1.44, demonstrating the magnitude of injury reduction due to factors other than device implementation. It was concluded that the device was effective in reduction of numbers of reported percutaneous injuries.^ Use-effectiveness of the system was also assessed by a survey of randomly selected device users to determine satisfaction with the device, frequency of use and barriers to use. Four hundred seventy-eight surveys were returned for a response rate of 50.9%. Approximately 94% of respondents at both hospitals expressed satisfaction with the needleless system and recommended continued use. The survey also revealed that even though over 50% of respondents report using the device "always" or "most of the time" for intravenous medication administration, flushing lines, and connecting secondary intravenous lines, needles were still being used for these same activities. Compatibility, accessibility and other technical problems were reported as reasons for using needles for these activities. These problems must be addressed, by both manufacturers and users, before the needleless system will be effective in prevention of all intravenous connection injuries. ^