4 resultados para Intrapulmonary Tidal Volume Distribution
em DigitalCommons@The Texas Medical Center
Resumo:
The potential for significant human populations to experience long-term inhalation of formaldehyde and reports of symptomatology due to this exposure has led to a considerable interest in the toxicologic assessment of risk from subchronic formaldehyde exposures using animal models. Since formaldehyde inhalation depresses certain respiratory parameters in addition to its other forms of toxicity, there is a potential for the alteration of the actual dose received by the exposed individual (and the resulting toxicity) due to this respiratory effect. The respiratory responses to formaldehyde inhalation and the subsequent pattern of deposition were therefore investigated in animals that had received subchronic exposure to the compound, and the potential for changes in the formaldehyde dose received due to long-term inhalation evaluated. Male Sprague-Dawley rats were exposed to either 0, 0.5, 3, or 15 ppm formaldehyde for 6 hours/day, 5 days/week for up to 6 months. The patterns of respiratory response, deposition and the compensation mechanisms involved were then determined in a series of formaldehyde test challenges to both the upper and to the lower respiratory tracts in separate groups of subchronically exposed animals and age-specific controls (four concentration groups, two time points). In both the control and pre-exposed animals, there was a characteristic recovery of respiratory parameters initially depressed by formaldehyde inhalation to at or approaching pre-exposure levels within 10 minutes of the initiation of exposure. Also, formaldehyde deposition was found to remain very high in the upper and lower tracts after long-term exposure. Therefore, there was probably little subsequent effect on the dose received by the exposed individual that was attributable to the repeated exposures. There was a diminished initial minute volume response in test challenges of both the upper and lower tracts of animals that had received at least 16 weeks of exposure to 15 ppm, with compensatory increases in tidal volume in the upper tract and respiratory rate in the lower tract. However, this dose-related effect was probably not relevant to human risk estimation because this formaldehyde dose is in excess of that experienced by human populations. ^
Resumo:
Intensity non-uniformity (bias field) correction, contextual constraints over spatial intensity distribution and non-spherical cluster's shape in the feature space are incorporated into the fuzzy c-means (FCM) for segmentation of three-dimensional multi-spectral MR images. The bias field is modeled by a linear combination of smooth polynomial basis functions for fast computation in the clustering iterations. Regularization terms for the neighborhood continuity of either intensity or membership are added into the FCM cost functions. Since the feature space is not isotropic, distance measures, other than the Euclidean distance, are used to account for the shape and volumetric effects of clusters in the feature space. The performance of segmentation is improved by combining the adaptive FCM scheme with the criteria used in Gustafson-Kessel (G-K) and Gath-Geva (G-G) algorithms through the inclusion of the cluster scatter measure. The performance of this integrated approach is quantitatively evaluated on normal MR brain images using the similarity measures. The improvement in the quality of segmentation obtained with our method is also demonstrated by comparing our results with those produced by FSL (FMRIB Software Library), a software package that is commonly used for tissue classification.
Resumo:
Proton therapy is growing increasingly popular due to its superior dose characteristics compared to conventional photon therapy. Protons travel a finite range in the patient body and stop, thereby delivering no dose beyond their range. However, because the range of a proton beam is heavily dependent on the tissue density along its beam path, uncertainties in patient setup position and inherent range calculation can degrade thedose distribution significantly. Despite these challenges that are unique to proton therapy, current management of the uncertainties during treatment planning of proton therapy has been similar to that of conventional photon therapy. The goal of this dissertation research was to develop a treatment planning method and a planevaluation method that address proton-specific issues regarding setup and range uncertainties. Treatment plan designing method adapted to proton therapy: Currently, for proton therapy using a scanning beam delivery system, setup uncertainties are largely accounted for by geometrically expanding a clinical target volume (CTV) to a planning target volume (PTV). However, a PTV alone cannot adequately account for range uncertainties coupled to misaligned patient anatomy in the beam path since it does not account for the change in tissue density. In order to remedy this problem, we proposed a beam-specific PTV (bsPTV) that accounts for the change in tissue density along the beam path due to the uncertainties. Our proposed method was successfully implemented, and its superiority over the conventional PTV was shown through a controlled experiment.. Furthermore, we have shown that the bsPTV concept can be incorporated into beam angle optimization for better target coverage and normal tissue sparing for a selected lung cancer patient. Treatment plan evaluation method adapted to proton therapy: The dose-volume histogram of the clinical target volume (CTV) or any other volumes of interest at the time of planning does not represent the most probable dosimetric outcome of a given plan as it does not include the uncertainties mentioned earlier. Currently, the PTV is used as a surrogate of the CTV’s worst case scenario for target dose estimation. However, because proton dose distributions are subject to change under these uncertainties, the validity of the PTV analysis method is questionable. In order to remedy this problem, we proposed the use of statistical parameters to quantify uncertainties on both the dose-volume histogram and dose distribution directly. The robust plan analysis tool was successfully implemented to compute both the expectation value and its standard deviation of dosimetric parameters of a treatment plan under the uncertainties. For 15 lung cancer patients, the proposed method was used to quantify the dosimetric difference between the nominal situation and its expected value under the uncertainties.
Resumo:
Background: The physical characteristic of protons is that they deliver most of their radiation dose to the target volume and deliver no dose to the normal tissue distal to the tumor. Previously, numerous studies have shown unique advantages of proton therapy over intensity-modulated radiation therapy (IMRT) in conforming dose to the tumor and sparing dose to the surrounding normal tissues and the critical structures in many clinical sites. However, proton therapy is known to be more sensitive to treatment uncertainties such as inter- and intra-fractional variations in patient anatomy. To date, no study has clearly demonstrated the effectiveness of proton therapy compared with the conventional IMRT under the consideration of both respiratory motion and tumor shrinkage in non-small cell lung cancer (NSCLC) patients. Purpose: This thesis investigated two questions for establishing a clinically relevant comparison of the two different modalities (IMRT and proton therapy). The first question was whether or not there are any differences in tumor shrinkage between patients randomized to IMRT versus passively scattered proton therapy (PSPT). Tumor shrinkage is considered a standard measure of radiation therapy response that has been widely used to gauge a short-term progression of radiation therapy. The second question was whether or not there are any differences between the planned dose and 5D dose under the influence of inter- and intra-fractional variations in the patient anatomy for both modalities. Methods: A total of 45 patients (25 IMRT patients and 20 PSPT patients) were used to quantify the tumor shrinkage in terms of the change of the primary gross tumor volume (GTVp). All patients were randomized to receive either IMRT or PSPT for NSCLC. Treatment planning goals were identical for both groups. All patients received 5 to 8 weekly repeated 4-dimensional computed tomography (4DCT) scans during the course of radiation treatments. The original GTVp contours were propagated to T50 of weekly 4DCT images using deformable image registration and their absolute volumes were measured. Statistical analysis was performed to compare the distribution of tumor shrinkage between the two population groups. In order to investigate the difference between the planned dose and the 5D dose with consideration of both breathing motion and anatomical change, we re-calculated new dose distributions at every phase of the breathing cycle for all available weekly 4DCT data sets which resulted 50 to 80 individual dose calculations for each of the 7 patients presented in this thesis. The newly calculated dose distributions were then deformed and accumulated to T50 of the planning 4DCT for comparison with the planned dose distribution. Results: At the end of the treatment, both IMRT and PSPT groups showed mean tumor volume reductions of 23.6% ( 19.2%) and 20.9% ( 17.0 %) respectively. Moreover, the mean difference in tumor shrinkage between two groups is 3% along with the corresponding 95% confidence interval, [-8%, 14%]. The rate of tumor shrinkage was highly correlated with the initial tumor volume size. For the planning dose and 5D dose comparison study, all 7 patients showed a mean difference of 1 % in terms of target coverage for both IMRT and PSPT treatment plans. Conclusions: The results of the tumor shrinkage investigation showed no statistically significant difference in tumor shrinkage between the IMRT and PSPT patients, and the tumor shrinkage between the two modalities is similar based on the 95% confidence interval. From the pilot study of comparing the planned dose with the 5D dose, we found the difference to be only 1%. Overall impression of the two modalities in terms of treatment response as measured by the tumor shrinkage and 5D dose under the influence of anatomical change that were designed under the same protocol (i.e. randomized trial) showed similar result.