1 resultado para Illinois. Office of Secretary of State. Index Dept.
em DigitalCommons@The Texas Medical Center
Resumo:
Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^