2 resultados para Idaho National Engineering Laboratory.

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this investigation, bromine-77 was produced with a medical cyclotron and imaged with gamma cameras. Br-77 emits a 240 kev photon with a half life of 56 hours. The C-Br bond is stronger than the C-I bond and bromine is not collected in the thyroid. Bromine can be used to label many organic molecules by methods analogous to radioiodination. The only North American source of Br-77 in the 70's and 80's was Los Alamos National Laboratory, but it discontinued production in 1989. In this method, a p,3n reaction on Br-77 produces Kr-77 which decays with a 1.2 hour half life to Br-77. A cyclotron generated 40 MeV proton beam is incident on a nearly saturated NaBr or LiBr solution contained in a copper or titanium target. A cooling chamber through which helium gas is flowed separates the solution from the cyclotron beam line. Helium gas is also flowed through the solution to extract Kr-77 gas. The mixture flows through a nitrogen trap where Kr-77 freezes and is allowed to decay to Br-77. Eight production runs were performed, three with a copper target and five with a titanium target with yields of 40, 104, 180, 679, 1080, 685, 762 and 118 uCi respectively. Gamma ray spectroscopy has shown the product to be very pure, however corrosion has been a major obstacle, causing the premature retirement of the copper target. Phantom and in-vivo rat nuclear images, and an autoradiograph in a rat are presented. The quality of the nuclear scans is reasonable and the autoradiograph reveals high isotope uptake in the renal parenchyma, a more moderate but uniform uptake in pulmonary and hepatic tissue, and low soft tissue uptake. There is no isotope uptake in the brain or the gastric mucosa. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The biological safety profession has historically functioned within an environment based on recommended practices rather than regulations, so summary data on compliance or noncompliance with recommended practices is largely absent from the professional literature. The absence of safety performance outcome data is unfortunate since the concept of biosafety containment is based on a combination of facility based controls and workplace practices, and persistent failures in either type of controls could ultimately result in injury or death. In addition, the number of laboratories requiring biosafety containment is likely to grow significantly in the coming years in the wake of the terrorist events of 2001. In this study, the outcomes of 768 biosafety level 2 (BSL-2) safety surveys were analyzed for commonalities and trends. Items of non-compliance noted were classified as facility related or practice related. The most frequent item of noncompliance encountered was the failure to re-certify biosafety cabinetry. Not surprisingly, the preponderance of the other frequent items of non-compliance encountered were practice related, such as general housekeeping orderly, changes in compliance levels, as well as establish trends in the elements of items of non-compliance during the sequential survey period. The findings described in this study are significant because, for the first time, the outcomes of compliance with recommended biosafety practices can be characterized and thus used as the basis for focused interventions. Since biosafety is heavily reliant on adherence to specific safety practices, the ability to focus interventions on objectively identified practice-related items of non-compliance can assist in the reduction of worker risk in this area experiencing tremendous growth. The information described is also of heighten importance given the number of workplaces expected to involve potentially infectious agents in the coming years. ^