3 resultados para INTERPLANETARY PARTICLES OR COSMIC DUST

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This MPH thesis consists of (1) literature review of the relatively new synthetic persistent organic pollutants (POP), polybrominated diphenyl ethers (PBDEs), a type of flame retardant posing a potential public health hazard, (2) Presentation of data on PBDE levels in dryer lint from Dallas, TX and Hamburg, Germany. ^ PBDEs are used as additive fire retardants in plastics, polyurethane foam and electronic equipment to reduce flammability and thus save life and property. PBDEs have been widely used beginning in the 1970s. They resemble polychlorinated biphenyls (PCBs) in structure and toxicity. PBDEs are found in environmental sediments, sludges, and wildlife and even in human blood, milk and tissues. ^ PBDEs, due to their lipophilicity, accumulate in fat and other tissues and biomagnify up the food chain, with increasing concentrations. Animal studies have suggested potential health effects including thyroid disruption, permanent learning and memory impairment, fetal malformations, developmental neurotoxicity and, at high doses, possibly cancer. ^ PBDE levels are increasing in blood and breast milk in North America, but PBDEs intake unlike PCBs appears to be not primarily through food; food PBDE levels in the U.S. are not markedly higher than in Europe yet U.S. human blood and milk levels are much higher. For this reason various exposure pathways including PBDE contaminated dust and air have been studied to better characterize routes of PBDE intake into humans. ^ The scientific literature on PBDE levels in household dust reports higher PBDE concentration in dust than that found in dryer lint; levels in the U.S are elevated compared to other countries with congeners such as BDE 47, 99, 100 and 209 predominating. The United Kingdom has elevated BDE 209 due to high usage of Deca commercial mixture. These studies suggest that indoor PBDE contamination through household dust could be a potential source of PBDE exposure and body burden especially in young children. ^ PBDE levels in dryer lint from U.S ranged from 321 to 3073 ng/g (Mean: 1138 ng/g, Median: 803 ng/g) and from Germany were from 330 to 2069 ng/g (Median: 71ng/g, Mean: 361 ng/g). High median levels in U.S samples indicate contamination of lint with PBDEs although the source of the PBDEs in lint may be from dryer electrical components or air deposition onto clothes, lint may be one source of PBDE exposure to humans. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This case control study was conducted to assess the association between lung cancer risk, mutagen sensitivity (a marker of cancer susceptibility), and a putative lung carcinogen, wood dust exposure. There were 165 cases (98 African-Americans, 67 Mexican-Americans) with newly diagnosed, previously untreated lung cancer, and 239 controls, frequency-matched on age, sex, and ethnicity.^ Mutagen sensitivity ($\ge$1 break/cell) was associated with a statistically significant elevated risk for lung cancer (odds ratio (OR) = 4.1, 95% confidence limits (CL) = 2.3,7.2). Wood dust exposure was also a significant predictor of risk (OR = 2.8, 95% CL = 1.2,6.6) after controlling for smoking and mutagen sensitivity. When stratified by ethnicity, wood dust exposure was a significant risk factor for African-Americans (OR = 4.0, 95% CL = 1.4,11.5), but not for Mexican-Americans (OR = 1.5, 95% CL = 0.3,7.1). Stratified analysis suggested a greater than multiplicative interaction between wood dust exposure and both mutagen sensitivity and smoking.^ The cases had significantly more breaks on chromosomes 4 and 5 than the controls did with ORs of 4.9 (95% CL = 2.0, 11.7) and 3.9 (95% CL = 1.6, 9.3), respectively. Breaks at 4p14, 4q27, 4q31, 5q21-22, 5q31, and 5q33 were significantly more common in lung cancer patients than in controls. Lung cancer risk had a dose-response relationship with breaks on chromosomes 4 and 5. Cigarette smoking had a strong interaction with breaks on chromosomes 2, 4, and 5.^ In a molecular cytogenetic study, using chromosome painting and G-banding, we showed that: (1) the proportion of chromosome 5 abnormalities surviving as chromosome-type aberrations remained significantly higher in cells of lung cancer cases (14%) than in controls (5%) (P $<$ 0.001). However, no significant differences were detected in chromosome 4 abnormalities between cases and controls; (2) the proportion of chromosome 5q13-22 abnormalities was 5.3% in the cases and 0.7% in the controls (P $<$ 0.001). 5q13-22 regions represented 40% of all abnormalities on chromosome 5 in the cases and only 14% in the controls.^ This study suggests that mutagen sensitivity, wood dust exposure, and cigarette smoking were independent risk factors for lung cancer, and the susceptibility of particular chromosome loci to mutagenic damage may be a genetic marker for specific types of lung cancer. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^