4 resultados para INJECTION CALIBRATION SYSTEM

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current analysis examined the association of several demographic and behavioral variables with prior HIV testing within a population of injection drug users (IDUs) living in Harris County, Texas in 2005 (n=563). After completing the initial univariate analyses of all potential predictors, a multivariable model was created. This model was designed to guide future intervention efforts. Data used in this analysis were collected by the University of Texas School of Public Health in association with the Houston Department of Health and Human Services for the first IDU cycle of the National HIV Behavioral Surveillance System. About 76% of the IDUs reported previously being tested for HIV. Demographic variables that displayed a significant association with prior testing during the univariate analyses include age, race/ethnicity, birth outside the United States, education level, recent arrest, and current health insurance coverage. Several drug-related and sexual behaviors also demonstrated significant associations with prior testing, including age of first injection drug use, heroin use, methamphetamine use, source of needles or syringes, consistent use of new needles, recent visits to a shooting gallery or similar location, previous alcohol or drug treatment, condom use during their most recent sexual encounter, and having sexual partners who also used injection drugs. Additionally, the univariate analyses revealed that recent use of health or HIV prevention services was associated with previously testing for HIV. The final multivariable model included age, race/ethnicity, recent arrest, previous alcohol or drug treatment, and heroin use. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Injection drug users (IDUs) are at increased risk for HIV transmission due to unique risk behaviors, such as sharing needles. In Houston, IDUs account for 18% of all HIV/AIDS cases among Black males. ^ Objectives. This analysis compared demographic, behavioral, and psychosocial characteristics of needle sharing and non-sharing IDUs in a population of Black males in Harris County, Texas. ^ Methods. Data used for this analysis were from the second IDU cycle of the National HIV Behavioral Surveillance System. This dataset included a sample of 288 Black male IDUs. Univariate and multivariate statistical analysis were performed to determine statistically significant associations of needle sharing in this population and to create a functional model to inform local HIV prevention programs. ^ Results. Half of the participants in this analysis shared needles in the past 12 months. Compared to non-sharers, sharers were more likely to be homeless (OR=3.70, p<0.01) or arrested in the past year (OR=2.31, p<0.01), inject cocaine (OR=2.07, p<0.01), report male-to-male sex in the past year (OR=6.97, p<0.01), and to exchange sex for money or drugs. Sharers were less likely than non-sharers to graduate high school (OR=0.36, p<0.01), earn $5,000 or more a year (OR=1.15, p=0.05), get needles from a medical source (OR=0.59, p=0.03), and ever test for HIV (OR=0.17, p<0.01). Sharers were more likely to report depressive symptoms (OR=3.49, p<0.01), lower scores on the family support scale (mean difference 0.41, p=0.01) and decision-making confidence scale (mean difference 0.38, p<0.01), and greater risk-taking (mean difference -0.49, p<0.01) than non-sharers. In a multivariable logistic regression, sharers were less likely to have graduated high school (OR=0.33, p<0.01) and have been tested for HIV (OR=0.12, p<0.01) and were more likely to have been arrested in the past year (OR=2.3, p<0.01), get needles from a street source (OR=3.87, p<0.01), report male-to-male sex (OR=7.01, p<0.01), and have depressive symptoms (OR=2.36, p=0.02) and increased risk-taking (OR=1.78, p=0.01). ^ Conclusions. IDUs that shared needles are different from those that did not, reporting lower socioeconomic status, increased sexual and risk behaviors, increased depressive symptoms and increased risk-taking. These findings suggest that intervention programs that also address these demographic, behavioral, and psychosocial factors may be more successful in decreasing needle sharing among this population.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.