2 resultados para IDEAL Reference Model
em DigitalCommons@The Texas Medical Center
Resumo:
Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state dosimeters in medical applications: thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the OSLD nanoDot in a CT environment, and to provide validated calibration procedures for CT dose measurement using OSLD. Current protocols for dose measurement using TLD and OSLD generally assume a constant photon energy spectrum within a nominal beam energy regardless of measurement location, tissue composition, or changes in beam parameters. Variations in the energy spectrum of therapeutic photon beams may impact the response of TLD and OSLD and could thereby result in an incorrect measure of dose unless these differences are accounted for. In this work, we used a Monte Carlo based model to simulate variations in the photon energy spectra of a Varian 6MV beam; then evaluated the impact of the perturbations in energy spectra on the response of both TLD and OSLD using Burlin Cavity Theory. Energy response correction factors were determined for a range of conditions and compared to measured correction factors with good agreement. When using OSLD for dose measurement in a diagnostic imaging environment, photon energy spectra are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; furthermore the dependence of the energy response of the calibration energy has not been emphasized. The results of this work include detailed calibration procedures for CT dosimetry using OSLD, and a full characterization of this dosimetry system in a low-dose, low-energy setting.
Resumo:
Background. The United Nations' Millennium Development Goal (MDG) 4 aims for a two-thirds reduction in death rates for children under the age of five by 2015. The greatest risk of death is in the first week of life, yet most of these deaths can be prevented by such simple interventions as improved hygiene, exclusive breastfeeding, and thermal care. The percentage of deaths in Nigeria that occur in the first month of life make up 28% of all deaths under five years, a statistic that has remained unchanged despite various child health policies. This paper will address the challenges of reducing the neonatal mortality rate in Nigeria by examining the literature regarding efficacy of home-based, newborn care interventions and policies that have been implemented successfully in India. ^ Methods. I compared similarities and differences between India and Nigeria using qualitative descriptions and available quantitative data of various health indicators. The analysis included identifying policy-related factors and community approaches contributing to India's newborn survival rates. Databases and reference lists of articles were searched for randomized controlled trials of community health worker interventions shown to reduce neonatal mortality rates. ^ Results. While it appears that Nigeria spends more money than India on health per capita ($136 vs. $132, respectively) and as percent GDP (5.8% vs. 4.2%, respectively), it still lags behind India in its neonatal, infant, and under five mortality rates (40 vs. 32 deaths/1000 live births, 88 vs. 48 deaths/1000 live births, 143 vs. 63 deaths/1000 live births, respectively). Both countries have comparably low numbers of healthcare providers. Unlike their counterparts in Nigeria, Indian community health workers receive training on how to deliver postnatal care in the home setting and are monetarily compensated. Gender-related power differences still play a role in the societal structure of both countries. A search of randomized controlled trials of home-based newborn care strategies yielded three relevant articles. Community health workers trained to educate mothers and provide a preventive package of interventions involving clean cord care, thermal care, breastfeeding promotion, and danger sign recognition during multiple postnatal visits in rural India, Bangladesh, and Pakistan reduced neonatal mortality rates by 54%, 34%, and 15–20%, respectively. ^ Conclusion. Access to advanced technology is not necessary to reduce neonatal mortality rates in resource-limited countries. To address the urgency of neonatal mortality, countries with weak health systems need to start at the community level and invest in cost-effective, evidence-based newborn care interventions that utilize available human resources. While more randomized controlled studies are urgently needed, the current available evidence of models of postnatal care provision demonstrates that home-based care and health education provided by community health workers can reduce neonatal mortality rates in the immediate future.^