5 resultados para Housing in Kerala
em DigitalCommons@The Texas Medical Center
Resumo:
Nitrogen dioxide (NO$\sb2)$ levels in sixteen substandard houses located in Houston, Texas were examined. The classification of the houses as substandard was based on an assessment of structural integrity which would affect air exchange rates. In these homes, unvented gas space heaters were operated as the primary source of heat.^ The Ogawa passive sampling device was used to measure NO$\sb2$ concentrations over 24 to 48-hour periods during generally cold weather. A sampler was placed in the kitchen and bedroom of each house. The female head of household was asked to wear a monitor during area monitoring to assess her personal exposure. Outdoor levels of NO$\sb2$ were also measured.^ Mean (standard deviation) levels of kitchen, bedroom and personal exposures were 280 (125) ppb, 256 (155) ppb and 164 (102) ppb, respectively. Additional short-term ($<$24 hours) samples were measured in three houses. The mean level of NO$\sb2$ measured outdoors was 51 ppb over the course of the study.^ The measurements obtained with the Ogawa sampler were compared to those levels obtained using a reference method (chemiluminescence). Outdoor levels measured with the diffusion samplers were 48% higher.^ These results suggest that wintertime NO$\sb2$ levels within substandard houses using gas appliances for heating and cooking are extremely elevated. Further work is needed to investigate the prevalence of possible health effects associated with these exposures. ^
Resumo:
A number of indoor environmental factors, including bioaerosol or aeroallergen concentrations have been identified as exacerbators for asthma and allergenic conditions of the respiratory system. People generally spend 90% to 95% of their time indoors. Therefore, understanding the environmental factors that affect the presence of aeroallergens indoors as well as outdoors is important in determining their health impact, and in identifying potential intervention methods. This study aimed to assess the relationship between indoor airborne fungal spore concentrations and indoor surface mold levels, indoor versus outdoor airborne fungal spore concentrations and the effect of previous as well as current water intrusion. Also, the association between airborne concentration of indoor fungal spores and surface mold levels and the age of the housing structure were examined. Further, the correlation between indoor concentrations of certain species was determined as well. ^ Air and surface fungal measurements and related information were obtained from a Houston-area data set compiled from visits to homes filing insurance claims. During the sampling visit these complaint homes exhibited either visible mold or a combination of visible mold and water intrusion problems. These data were examined to assess the relationships between the independent and dependent variables using simple linear regression analysis, and independent t-tests. To examine the correlation between indoor concentrations of certain species, Spearman correlation coefficients were used. ^ There were 126 houses sampled, with spring, n=43 (34.1%), and winter, n=42 (33.3%), representing the seasons with the most samples. The summer sample illustrated the highest geometric mean concentration of fungal spores, GM=5,816.5 relative to winter, fall and spring (GM=1,743.4, GM=3,683.5 and GM=2,507.4, respectively). In all seasons, greater concentrations of fungal spores were observed during the cloudy weather conditions. ^ The results indicated no statistically significant association between outdoor total airborne fungal spore concentration and total living room airborne fungal spore concentration (β = 0.095, p = 0.491). Second, living room surface mold levels were not associated with living room airborne fungal spore concentration, (β= 0.011, p = 0.669). Third, houses with and without previous water intrusion did not differ significantly with respect to either living room (t(111) = 0.710, p = 0.528) or bedroom (t(111) =1.673, p = 0.162) airborne fungal spore concentrations. Likewise houses with and without current water intrusion did not differ significantly with respect to living room (t(109)=0.716, p = 0.476) or bedroom (t(109) = 1.035, p = 0.304) airborne fungal spore concentration. Fourth, houses with and without current water intrusion did not differ significantly with respect to living room (χ 2 (5) = 5.61, p = 0.346), or bedroom (χ 2 (5) = 1.80, p = 0.875) surface mold levels. Fifth, the age of the house structure did not predict living room (β = 0.023, p = 0.102) and bedroom (β = 0.023, p = 0.065) surface mold levels nor living room (β = 0.002, p = 0.131) and bedroom (β = 0.001, p = 0.650) fungal spore airborne concentration. Sixth, in houses with visually observed mold growth there was statistically significant differences between the mean living room concentrations and mean outdoor concentrations for Cladosporium (t (107) = 11.73, p < 0.0001), Stachybotrys (t (106)=2.288, p = 0.024, and Nigrosporia (t (102) = 2.267, p = 0.025). Finally, there was a significant correlation between several living room fungal species pairs, namely, Cladosporium and Stachybotrys (r = 0.373, p <0.01, n=65), Curvularia and Aspergillus/Penicillium (r = 0.205, p < 0.05, n= 111)), Curvularia and Stachybotrys (r = 0.205, p < 0.05, n=111), Nigrospora and Chaetomium (r = 0.254, p < 0.01, n=105) and Stachybotrys and Nigrospora (r = 0.269, p < 0.01, n=105). ^ This study has demonstrated several positive findings, i.e., significant pairwise correlations of concentrations of several fungal species in living room air, and significant differences between indoor and outdoor concentrations of three fungal species in homes with visible mold. No association was observed between indoor and outdoor fungal spore concentrations. Neither living room nor bedroom airborne spore concentrations and surface mold levels were related to the age of the house or to water intrusion, either previous or current. Therefore, these findings suggest the need for evaluating additional parameters, as well as combinations of factors such as humidity, temperature, age of structure, ventilation, and room size to better understand the determinants of airborne fungal spore concentrations and surface mold levels in homes. ^
Resumo:
Integrated pest management is a viable alternative to traditional pest control methods. A paired sample design was utilized to measure the effect of IPM education on the number of cockroaches in a 200 unit, seven story public housing building for the elderly in Houston, TX. Glue traps were placed in 71 randomly selected apartments (5traps/unit) and left in place for two nights. Baseline cockroach counts were shared with the property manager, maintenance/janitorial staff, service coordinator, pest control professional and tenant representatives at the end of a one day “Integrated Pest Management in Multi-Family Housing” training course.^ There was a significant decrease in the average number of cockroaches after IPM education and implementation of IPM principles (P < 0.0003). Positive changes in behavior by members of the IPM team and changes in the housing authority operational plan were also found. Paired t-tests comparing the difference between mean cockroach counts at baseline and follow-up by location within the apartment all demonstrated a significant decrease in the number of cockroaches.^ Results supported the premise that IPM education and the implementation of IPM principles are effective measures to change pest control behaviors and control cockroaches. Cockroach infestations in multi-story housing are not solely determined by the actions of individual tenants. The actions of other residents, property managers and pest control professionals are also important factors in pest control.^ Findings support the implementation of IPM education and the adoption of IPM practices by public housing authorities. This study adds to existing evidence that clear communication of policies, a team approach and a commitment to ongoing inspection and monitoring of pests combined with corrective action to eliminate food, water and harborage and the judicial use of low risk pesticides have the potential to improve the living conditions of elderly residents living in public housing.^
Resumo:
Natural disasters occur in various forms such as hurricanes, tsunamis, earthquakes, outbreaks, etc. The most unsettling aspect of a natural disaster is that it can strike at any moment. Over the past decade, our society has experienced an alarming increase of natural disasters. How to expeditiously respond and recover from natural disasters has become a precedent question for public health officials. To date, the most recent natural disaster was the January 12, 2010 earthquake in Haiti; however the most memorable was that of Hurricane Katrina (“Haiti Earthquake”, 2010). ^ This study provides insight on the need to develop a National Disaster Response and Recovery Program which effectively responds to natural disasters. The specific aims of this paper were to (1) observe the government’s role on federal, state and local levels in assisting Hurricanes Katrina and Rita evacuees, (2) assess the prevalence of needs among Hurricanes Katrina and Rita families participating in the Disaster Housing Assistance Program (DHAP) and (3) describe the level of progress towards “self sufficiency” for the DHAP families receiving case management social services. ^ Secondary data from a cross-sectional “Needs Assessment” questionnaire were analyzed. The questionnaire was administered initially and again six months later (follow-up) by H.A.U.L. case managers. The “Needs Assessment” questionnaire collected data regarding participants’ education, employment, transportation, child care, health resources, income, permanent housing and disability needs. Case managers determined the appropriate level of social services required for each family based on the data collected from the “Needs Assessment” questionnaire. ^ Secondary data provided by the H.A.U.L. were analyzed to determine the prevalence of needs among the DHAP families. In addition, differences measured between the initial and follow-up (at six months) questionnaires were analyzed to determine statistical significance between case management services provided and prevalence of needs among the DHAP families from initial to 6 months later at follow-up. The data analyzed describe the level of progress made by these families to achieve program “self sufficiency” (see Appendix A). Disaster assistance programs which first address basic human needs; then socioeconomic needs may offer an essential tool in aiding disaster affected communities quickly recover from natural disasters. ^
Resumo:
Manufactured housing has been found to have substantial levels of formaldehyde in the indoor air. Because mobile homes are more affordable than conventional housing, there has been a large increase in their use in the U.S. This increase in mobile home use has been substantial in the sunbelt regions such as Texas, where high temperatures and humidities may enhance out-gassing of formaldehyde and other volatile organic compounds from construction and furnishing materials and increase any potential health hazards.^ The influences of environmental, architectural and temporal factors on the presence of indoor formaldehyde and other organic compounds were investigated in conjunction with the Texas Indoor Air Quality Study of manufactured housing. A matched pair of mobile homes, one with electric heating and cooking utilities and the other with propane gas utilities, were used for a series of controlled experiments over a fourteen month period from October, 1982 through November, 1983.^ Over this fourteen month period formaldehyde levels decreased approximately 33%. Daily fluctuations of 20% to 40% were observed even with a constant indoor temperature. An increase in indoor temperature of 8(DEGREES)C doubled the measured formaldehyde concentration. Opening windows resulted in decreases of indoor formaldehyde levels of up to 50%. Studies of the impact of propane as a cooking source showed no increase in formaldehyde levels with stove use.^ The presence and concentration of selected volatile organic compounds is influenced greatest by occupancy. Occupants continually open and close windows and doors, vary the operation and settings (temperature) of air control systems, and vary in their selection of furnishings and use of consumer products, which may act as sources of indoor air contaminants. ^