2 resultados para Hardware-in-the-loop,air spring
em DigitalCommons@The Texas Medical Center
Resumo:
This study was conducted by either literature review or actual field survey. Results are summarized as follows: (1) Long-term occupational exposure of workers to benzene vapor at levels of 3-7 ppm, 2-3 ppm and 1.6 ppm may result in a decreased level of leucocyte alkaline phosphates, an increased incidence of chromosome aberrations and an increased level of ALA in erythrocytes, respectively; (2) Benzene is capable of causing fetotoxic effects in animals at levels as low as 10 ppm by volume; (3) Exposure of animals to or less than 1 ppm benzene vapor may result in leucopenia, an inverse ratio of muscle antagonist chronaxy and a decreased level of ascorbic acid in fetus's and mother's liver as well as whole embryo; (4) Benzene is causally associated with the increased incidence of pancytopenia, including unicytopenia, bicytopenia and aplastic anemia, and chromosome aberrations in occupational exposure population, and at best benzene must also be considered as a leukemogen; (5) Since it can be emitted into the atmosphere from both man-made and natural sources, benzene in some concentrations is present everywhere in the various compartments of the environment; (6) The findings of the emission of benzene from certain natural sources indicate that reducing benzene to a zero-level of exposure is theoretically impossible; (7) The annual average of benzene concentration detected in the Houston ambient air is 2.50 ppb, which is about 2.4 times higher than the nation-wide annual average exposure level and may have been some health implications to the general public; (8) In the Houston area, stationary sources are more important than mobile sources in contributing to benzene in the ambient air. ^
Resumo:
Manufactured housing has been found to have substantial levels of formaldehyde in the indoor air. Because mobile homes are more affordable than conventional housing, there has been a large increase in their use in the U.S. This increase in mobile home use has been substantial in the sunbelt regions such as Texas, where high temperatures and humidities may enhance out-gassing of formaldehyde and other volatile organic compounds from construction and furnishing materials and increase any potential health hazards.^ The influences of environmental, architectural and temporal factors on the presence of indoor formaldehyde and other organic compounds were investigated in conjunction with the Texas Indoor Air Quality Study of manufactured housing. A matched pair of mobile homes, one with electric heating and cooking utilities and the other with propane gas utilities, were used for a series of controlled experiments over a fourteen month period from October, 1982 through November, 1983.^ Over this fourteen month period formaldehyde levels decreased approximately 33%. Daily fluctuations of 20% to 40% were observed even with a constant indoor temperature. An increase in indoor temperature of 8(DEGREES)C doubled the measured formaldehyde concentration. Opening windows resulted in decreases of indoor formaldehyde levels of up to 50%. Studies of the impact of propane as a cooking source showed no increase in formaldehyde levels with stove use.^ The presence and concentration of selected volatile organic compounds is influenced greatest by occupancy. Occupants continually open and close windows and doors, vary the operation and settings (temperature) of air control systems, and vary in their selection of furnishings and use of consumer products, which may act as sources of indoor air contaminants. ^