15 resultados para HADES – Hades Active Delay Evaluation System
em DigitalCommons@The Texas Medical Center
Resumo:
The p53 tumor suppressor gene product is negatively regulated by the product of its downstream target, mdm2. The mdm2 oncogene abrogates p53 transactivation function. Amplification of mdm2 occurs in 36% of human sarcomas, which often retain p53 in wild type form, suggesting that overexpression of mdm2 in tumors results in p53 inactivation. Thus, the relationship of p53 to mdm2 is important in tumorigenesis. The deletion of mdm2 in the mouse results in embryonic lethality by 5.5 days post coitum. Embryonic lethality of the mdm2 null embryos was overcome by simultaneous loss of the p53 tumor suppressor, which substantiates the importance of the negative regulatory function of MDM2 on p53 function in vivo. These data suggest that the loss of MDM2 function allowed the constitutively active p53 protein to induce either a complete G1 arrest or the p53-dependent apoptotic pathway, resulting in the death of the mdm2−/− embryos.^ The present study examines the hypothesis that the absence of mdm2 induces apoptosis due to p53 activation. Viability of the p53−/−mdm2−/− mice has allowed establishment of mouse embryo fibroblasts (MEFs) and a detailed examination of the properties of these cells. To introduce p53 into this system, and essentially recreate a mdm2 null cell, a temperature sensitive p53 (tsp53) point mutant (A135V) was used, which exhibits a nonfunctional, mutant conformation at 39°C and wild type, functional conformation at 32°C. Infected pools of p53−/− and p53−/−mdm2−/− MEFs with the tsp53 gene were established and single-cell clonal populations expressing tsp53 were selected. Shifting the cells from 39°C to 32°C caused p53−/−mdm2 −/− lines expressing tsp53 to undergo up to 80% apoptosis, which did not occur in the p53−/− lines expressing tsp53 nor the parental lines lacking p53 expression. Furthermore, the amount of p53 present in the clonal population determined the extent of apoptosis. Tsp53 is transcriptionally active in this system, however, it discriminates among different target promoters and does not induce the apoptosis effector targets bax or Fas/Apo1. ^ In summary, this study indicates that the presence or absence of mdm2 is the determining factor for the ability of p53 to trigger apoptosis in this system. The loss of mdm2 promotes p53-dependent apoptosis in MEFs in a cell cycle and dose-dependent manner. p53 is differentially phosphorylated in the presence and absence of mdm2, but does not induce the apoptosis effectors, bax or Fas/ Apo1. ^
Resumo:
In a previous paper, we presented a proposed expansion of the National Guideline Clearing-house (NGC) classification1. We performed a preliminary evaluation of the classification based on 100 guidelines randomly selected from the NGC collection. We found that 89 of the 100 guidelines could be assigned to a single guideline category. To test inter-observer agreement, twenty guidelines were also categorized by a second investigator. Agreement was found to be 40-90% depending on the axis, which compares favorably with agreement among MeSH indexers (30-60%)2. We conclude that categorization is feasible. Further research is needed to clarify axes with poor inter-observer agreement.
Resumo:
The Personal Response System Program at Huffington Center on Aging, Baylor College of Medicine, provides emergency call systems for elderly people living independently in Houston, Texas. The goal of the project was to complete a formative evaluation of the Personal Response System Program. The specific aims of the evaluation were three-fold. One aim was to evaluate participant health status and level of disability. The second aim was to develop a health care cost estimation strategy. Finally, a preliminary cost-effectiveness analysis was completed to evaluate the program's impact on health care costs and health status among the elderly target population. ^ The evaluation was a longitudinal, randomized experimental design. After the screening of 120 volunteers for eligibility, clients were asked to complete a written questionnaire and a monthly health service contact diary. Volunteers were contacted by telephone interviewers to collect health status information from 100 eligible clients (83%) on three occasions during the six months of follow-up. ^ Initially, volunteers were randomized to two experimental groups. The two groups were found to be comparable at the beginning of the study. No significant differences were detected related to health status, level of disability, or history of physician visits at baseline. However, the group with the Personal Response System (PRS) device had more adverse health events, higher IADL scores, more frequent use of walkers, lower average health status scores, and fewer community volunteers hours than the usual care comparison group. ^ The health care costs were estimated based on an algorithm adapted from the American Medical Association guidelines. Average total health care costs for the group with the PRS device ($912) were greater than the usual care group ($464). However, median health care values for the PRS group ($263) were similar to the usual care comparison group ($234). The preliminary findings indicated that the use of the PRS device was not associated with health care cost savings. ^ In the preliminary cost-effectiveness analysis, use of the personal response system was found to be associated with increased mental health status among elderly clients. The cost-effectiveness evaluation indicated that the associated cost for six months was $710 per unit increase in mental component score when the $150 PRS subscription was included. However, clients with the PRS device were found to have a greater decline in physical health status during the six-month follow-up. The beneficial effect on mental health status was found to be in contrast to negative findings associated with changes in physical health status. The implications for future research relate to the need to identify risk factors among geriatric populations to better target groups that would most likely benefit from PRS Program enrollment. ^
Resumo:
Early Employee Assistance Programs (EAPs) had their origin in humanitarian motives, and there was little concern for their cost/benefit ratios; however, as some programs began accumulating data and analyzing it over time, even with single variables such as absenteeism, it became apparent that the humanitarian reasons for a program could be reinforced by cost savings particularly when the existence of the program was subject to justification.^ Today there is general agreement that cost/benefit analyses of EAPs are desirable, but the specific models for such analyses, particularly those making use of sophisticated but simple computer based data management systems, are few.^ The purpose of this research and development project was to develop a method, a design, and a prototype for gathering managing and presenting information about EAPS. This scheme provides information retrieval and analyses relevant to such aspects of EAP operations as: (1) EAP personnel activities, (2) Supervisory training effectiveness, (3) Client population demographics, (4) Assessment and Referral Effectiveness, (5) Treatment network efficacy, (6) Economic worth of the EAP.^ This scheme has been implemented and made operational at The University of Texas Employee Assistance Programs for more than three years.^ Application of the scheme in the various programs has defined certain variables which remained necessary in all programs. Depending on the degree of aggressiveness for data acquisition maintained by program personnel, other program specific variables are also defined. ^
Resumo:
The heparan sulfate (HS)-fibroblast growth factor (FGF) signaling system is a ubiquitous regulator that senses local environmental changes and mediates cell-to-cell communication. This system consists of three mutually interactive components. These are regulatory polypeptides (FGF), FGF receptor (FGFR) and heparan sulfate proteoglycans (FGFRHS). All four FGFR genes are expressed in the adult liver. Expression of the FGFR1–3 genes is generally associated with non-parenchymal cells while expression of the FGFR4 gene is associated with parenchymal hepatocytes. We showed that livers of mice lacking FGFR4 exhibited normal morphology and regenerated normally in response to partial hepatectomy. However, the FGFR4 (−/−) mice exhibited depleted gallbladders, an elevated bile acid pool and elevated excretion of bile acids. Cholesterol- and bile acid-controlled liver cholesterol 7α-hydroxylase (Cyp7a), the limiting enzyme for bile acid synthesis, was elevated, unresponsive to dietary cholesterol, but repressed normally by dietary cholate. These results indicated that FGFR4 was not directly involved in liver growth but exerted negative control on liver bile acid synthesis. This was confirmed in transgenic mice overexpressing the constitutively active human FGFR4 in livers. The transgenic mice exhibited decreased fecal bile acid excretion, bile acid pool size, and expression of Cyp7a. Introduction of this constitutively active human FGFR4 into FGFR4 (−/−) mice restored the inhibition of bile acid synthesis. Activation of the c-Jun N-terminal Kinase (JNK) pathway by FGFR4 correlated with the repressive effect on bile acid synthesis. ^ To determine whether FGFR4 played a broader role in liver-specific metabolic function, we examined the impact of both acute and chronic exposure to CCl 4 in FGFR4 (−/−) mice. Following acute CCl4 exposure, the FGFR4 (−/−) mice exhibited accelerated liver injury, a significant increase in liver mass and delayed hepatolobular repair, with no apparent effect on liver cell proliferation and restoration of cellularity. Chronic CCl4 exposure resulted in severe fibrosis in livers of FGFR4 (−/−) mice compared to normal mice. Analysis at both mRNA and protein levels indicated an 8 hr delay in FGFR4-deficient mice in the down-regulation of cytochrome P450 2E1 (CYP2E1) protein, the major enzyme whose products underlie CCl 4-induced injury. These results show that hepatocyte FGFR4 protects against acute and chronic insult to the liver and prevents accompanying fibrosis. ^ Of the 23 FGF polypeptides, FGF1 and FGF2 are present at significant levels in the liver. To determine whether FGF1 and FGF2 played a role in CCl 4-induced liver injury and fibrosis, we examined the impact of both acute and chronic exposure to CCl4 in both wild-type and FGF1-FGF2 double-knockout mice. Following acute CCl4 exposure, FGF1(−/−)FGF2(−/−) mice exhibited accelerated liver injury, overall normal liver growth and repair, and decreased liver collagen α1(I) induction. Liver fibrosis resulting from chronic CCl4 exposure was markedly decreased in livers of FGF1(−/−)FGF2(−/−) mice compared to wild-type mice. This study suggests a role for FGF1 and FGF2 in hepatic fibrogenesis. ^ In summary, our three part study shows that specific components of the ubiquitous HS-FGF signaling family in the liver context interfaces with metabolite- and xenobiotic-controlled networks to regulate liver function, but has no apparent direct effect on liver cell growth. ^
Resumo:
The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^
Resumo:
In the United States, “binge” drinking among college students is an emerging public health concern due to the significant physical and psychological effects on young adults. The focus is on identifying interventions that can help decrease high-risk drinking behavior among this group of drinkers. One such intervention is Motivational interviewing (MI), a client-centered therapy that aims at resolving client ambivalence by developing discrepancy and engaging the client in change talk. Of late, there is a growing interest in determining the active ingredients that influence the alliance between the therapist and the client. This study is a secondary analysis of the data obtained from the Southern Methodist Alcohol Research Trial (SMART) project, a dismantling trial of MI and feedback among heavy drinking college students. The present project examines the relationship between therapist and client language in MI sessions on a sample of “binge” drinking college students. Of the 126 SMART tapes, 30 tapes (‘MI with feedback’ group = 15, ‘MI only’ group = 15) were randomly selected for this study. MISC 2.1, a mutually exclusive and exhaustive coding system, was used to code the audio/videotaped MI sessions. Therapist and client language were analyzed for communication characteristics. Overall, therapists adopted a MI consistent style and clients were found to engage in change talk. Counselor acceptance, empathy, spirit, and complex reflections were all significantly related to client change talk (p-values ranged from 0.001 to 0.047). Additionally, therapist ‘advice without permission’ and MI Inconsistent therapist behaviors were strongly correlated with client sustain talk (p-values ranged from 0.006 to 0.048). Simple linear regression models showed a significant correlation between MI consistent (MICO) therapist language (independent variable) and change talk (dependent variable) and MI inconsistent (MIIN) therapist language (independent variable) and sustain talk (dependent variable). The study has several limitations such as small sample size, self-selection bias, poor inter-rater reliability for the global scales and the lack of a temporal measure of therapist and client language. Future studies might consider a larger sample size to obtain more statistical power. In addition the correlation between therapist language, client language and drinking outcome needs to be explored.^
Resumo:
Introduction: The Texas Occupational Safety & Health Surveillance System (TOSHSS) was created to collect, analyze and interpret occupational injury and illness data in order to decrease the impact of occupational injuries within the state of Texas. This process evaluation was performed midway through the 4-year grant to assess the efficiency and effectiveness of the surveillance system’s planning and implementation activities1. ^ Methods: Two evaluation guidelines published by the Centers for Disease Control and Prevention (CDC) were used as the theoretical models for this process evaluation. The Framework for Program Evaluation in Public Health was used to examine the planning and design of TOSHSS using logic models. The Framework for Evaluating Public Health Surveillance Systems was used to examine the implementation of approximately 60 surveillance activities, including uses of the data obtained from the surveillance system. ^ Results/Discussion: TOSHSS planning activities omitted the creation of a scientific advisory committee and specific activities designed to maintain contacts with stakeholders; and proposed activities should be reassessed and aligned with ongoing performance measurement criteria, including the role of collaborators in helping the surveillance system achieve each proposed activity. TOSHSS implementation activities are substantially meeting expectations and received an overall score of 61% for all activities being performed. TOSHSS is considered a surveillance system that is simple, flexible, acceptable, fairly stable, timely, moderately useful, with good data quality and a PVP of 86%. ^ Conclusions: Through the third year of TOSHSS implementation, the surveillance system is has made a considerable contribution to the collection of occupational injury and illness information within the state of Texas. Implementation of the nine recommendations provided under this process evaluation is expected to increase the overall usefulness of the surveillance system and assist TDSHS in reducing occupational fatalities, injuries, and diseases within the state of Texas. ^ 1 Disclaimer: The Texas Occupational Safety and Health Surveillance System is supported by Grant/Cooperative Agreement Number (U60 OH008473-01A1). The content of the current evaluation are solely the responsibility of the authors and do not necessarily represent the official views of the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.^
Resumo:
This research was intended to evaluate an automated ambulatory medical record and chart review system. Chart review as conceptualized in this research is a series of statements that are made by the computer after reviewing the patients entire computer medical record. The actual chart review st
Resumo:
An experimental procedure was developed using the Brainstem Evoked Response (BER) electrophysiological technique to assess the effect of neurotoxic substances on the auditory system. The procedure utilizes Sprague-Dawley albino rats who have had dural electrodes implanted in their skulls, allowing neuroelectric evoked potentials to be recorded from their brainstems. Latency and amplitude parameters derived from the evoked potentials help assess the neuroanatomical integrity of the auditory pathway in the brainstem. Moreover, since frequency-specific auditory stimuli are used to evoke the neural responses, additional audiometric information is obtainable. An investigation on non-exposed control animals shows the BER threshold curve obtained by tests at various frequencies very closely approximates that obtained by behavioral audibility tests. Thus, the BER appears to be a valid measure of both functional and neuroanatomical integrity of the afferent auditory neural pathway.^ To determine the usefulness of the BER technique in neurobehavioral toxicology research, a known neurotoxic agent, Pb, was studied. Female Sprague-Dawley rats were dosed for 45 days with low levels of Pb acetate in their drinking water, after which BER recordings were obtained. The Pb dosages were determined from the findings of an earlier pilot study. One group of 6 rats received normal tap water, one group of 7 rats received a solution of 0.1% Pb, and another group of 7 rats received a solution of 0.2% Pb. After 45 days, the three groups exhibited blood Pb levels of 4.5 (+OR-) 0.43 (mu)g/100 ml, 37.8 (+OR-) 4.8 (mu)g/100 ml and 47.3 (+OR-) 2.7 (mu)g/100 ml, respectively.^ The results of the BER recording indicated evoked response waveform latency abnormalities in both the Pb-treated groups when midrange frequency (8 kHz to 32 kHz) stimuli were used. For the most part, waveform amplitudes did not vary significantly from control values. BER recordings obtained after a 30-day recovery period indicated the effects seen in the 0.1% Pb group had disappeared. However, those anomalies exhibited by the 0.2% Pb group either remained or increased in number. This outcome indicates a longer lasting or possibly irreversible effect on the auditory system from the higher dose of Pb. The auditory pathway effect appears to be in the periphery, at the level of the cochlea or the auditory (VIII) nerve. The results of this research indicate the BER technique is a valuable and sensitive indicator of low-level toxic effects on the auditory system.^
Resumo:
The development of the Alcohol Treatment Profile System (ATPS) was described and an evaluation of its perceived value by various States was undertaken, The ATPS is a treatment needs assessment tool based on the unification of several large national epidemiologic and treatment data sets. It was developed by the National Institute on Alcohol Abuse and Alcoholism (NIAAA) and responsibility for its creation was given to the NIAAA's Alcohol Epidemiologic Data System (AEDS). The ATPS merges county-level measures of alcohol problem prevalence (the specially constructed AEDS Alcohol Problem Indicators), indicating "need" for treatment, and treatment utilization measures (the National Drug and Alcohol Treatment Utilization Survey), indicating treatment "demand." The capabilities of the ATPS in the unique planning and policy-making settings of several States were evaluated.^
Resumo:
Background: The Sacred Vocation Program (SVP) (Amick B, Karff S., 2003) helps workers find meaning, spirituality, and see their job as a sacred vocation. The SVP is based on Participatory Action Research (PAR) (Minkler & Wallerstein, 1997; Parker & Wall, 1998). This study aims to evaluate the SVP implemented at the Baylor Healthcare System, Dallas-Fort Worth. ^ Methods: The study design is a qualitative design. We used data from study participants who have participated in focus groups. During these focus groups specific questions and probes regarding the effectiveness of the SVP have been asked. We analyzed the focus groups and derived themes. ^ Results: Results of this study demonstrate SVP helps graduates feel valued and important. The SVP has improved meaningful work for employees and improved a sense of belonging for participants. The program has also increased participant spirituality. The coping techniques developed during a SVP class helps participants deal with stressful situations. The SVP faces challenges of implementation fidelity, poor communication, program viability in tough economic times and implementation of phase II. Another sustainability challenge for SVP is the perception of the program being a religious one versus a spiritual program. ^ Conclusion: Several aspects of the SVP work. The phase I of SVP is successful in improving meaningful work and a sense of belonging for participants. The coping techniques help participants deal with difficult work situations. The SVP can increase effectiveness through improvements in implementation fidelity, communication and leadership commitment. ^
Resumo:
Recent developments in federal policy have prompted the creation of state evaluation frameworks for principals and teachers that hold educators accountable for effective practices and student outcomes. These changes have created a demand for formative evaluation instruments that reflect current accountability pressures and can be used by schools to focus school improvement and leadership development efforts. The Comprehensive Assessment of Leadership for Learning (CALL) is a next generation, 360-degree on-line assessment and feedback system that reflect best practices in feedback design. Some unique characteristics of CALL include a focus on: leadership distributed throughout the school rather than as carried out by an individual leader; assessment of leadership tasks rather than perceptions of leadership practice; a focus on larger complex systems of middle and high school; and transparency of assessment design. This paper describes research contributing to the design and validation of the CALL survey instrument.
Resumo:
High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.
Resumo:
Background: Obesity is a major health problem in the United States that has reached epidemic proportions. With most U.S adults spending the majority of their waking hours at work, the influence of the workplace environment on obesity is gaining in importance. Recent research implicates worksites as providing an 'obesogenic' environment as they encourage overeating and reduce the opportunity for physical activity. Objective: The aim of this study is to describe the nutrition and physical activity environment of Texas Medical Center (TMC) hospitals participating in the Shape Up Houston evaluation study to develop a scoring system to quantify the environmental data collected using the Environmental Assessment Tool (EAT) survey and to assess the inter-observer reliability of using the EAT survey. Methods: A survey instrument that was adapted from the Environmental Assessment Tool (EAT) developed by Dejoy DM et al in 2008 to measure the hospital environmental support for nutrition and physical activity was used for this study. The inter-observer reliability of using the EAT survey was measured and total percent agreement scores were computed. Most responses on the EAT survey are dichotomous (Yes and No) and these responses were coded with a '0' for a 'no' response and a '1' for a 'yes' response. A summative scoring system was developed to quantify these responses. Each hospital was given a score for each scale and subscale on the EAT survey in addition to a total score. All analyses were conducted using Stata 11 software. Results: High inter-observer reliability is observed using EAT. The percentage agreement scores ranged from 94.4%–100%. Only 2 of the 5 hospitals had a fitness facility onsite and scores for exercise programs and outdoor facilities available for hospital employees ranged from 0–62% and 0–37.5%, respectively. The healthy eating percentage for hospital cafeterias range from 42%–92% across the different hospitals while the healthy vending scores were 0%–40%. The total TMC 'healthy hospital' score was 49%. Conclusion: The EAT survey is a reliable instrument for measuring the physical activity and nutrition support environment of hospital worksites. The study results showed a large variability among the TMC hospitals in the existing physical activity and nutrition support environment. This study proposes cost effective policy changes that can increase environmental support to healthy eating and active living among TMC hospital employees.^