8 resultados para Grievance procedures

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Medical schools are charged with providing both a strong basic science and clinical curriculum for their students. In most institutions instruction in performing the core clinical procedures is part of the curriculum, but because of many constraints do medical students practice these procedures as many times as medical students in the past? Several studies have concluded that medical students today feel incompetent to perform basic clinical procedures at the time of graduation. [See PDF for complete abstract]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into the phantom material. Two treatment plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility of ±3%. The hypothesis was accepted and the phantom was found to be suitable for remote audits of proton therapy treatment facilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In epidemiology literature, it is often required to investigate the relationships between means where the levels of experiment are actually monotone sets forming a partition on the range of sampling values. With this need, the analysis of these group means is generally performed using classical analysis of variance (ANOVA). However, this method has never been challenged. In this dissertation, we will formulate and present our examination of its validity. First, the classical assumptions of normality and constant variance are not always true. Second, under the null hypothesis of equal means, the test statistic for the classical ANOVA technique is still valid. Third, when the hypothesis of equal means is rejected, the classical analysis techniques for hypotheses of contrasts are not valid. Fourth, under the alternative hypothesis, we can show that the monotone property of levels leads to the conclusion that the means are monotone. Fifth, we propose an appropriate method for handing the data in this situation. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Childhood immunization programs have dramatically reduced the morbidity and mortality associated with vaccine-preventable diseases. Proper documentation of immunizations that have been administered is essential to prevent duplicate immunization of children. To help improve documentation, immunization information systems (IISs) have been developed. IISs are comprehensive repositories of immunization information for children residing within a geographic region. The two models for participation in an IIS are voluntary inclusion, or "opt-in," and voluntary exclusion, or "opt-out." In an opt-in system, consent must be obtained for each participant, conversely, in an opt-out IIS, all children are included unless procedures to exclude the child are completed. Consent requirements for participation vary by state; the Texas IIS, ImmTrac, is an opt-in system.^ Objectives. The specific objectives are to: (1) Evaluate the variance among the time and costs associated with collecting ImmTrac consent at public and private birthing hospitals in the Greater Houston area; (2) Estimate the total costs associated with collecting ImmTrac consent at selected public and private birthing hospitals in the Greater Houston area; (3) Describe the alternative opt-out process for collecting ImmTrac consent at birth and discuss the associated cost savings relative to an opt-in system.^ Methods. Existing time-motion studies (n=281) conducted between October, 2006 and August, 2007 at 8 birthing hospitals in the Greater Houston area were used to assess the time and costs associated with obtaining ImmTrac consent at birth. All data analyzed are deidentified and contain no personal information. Variations in time and costs at each location were assessed and total costs per child and costs per year were estimated. The cost of an alternative opt-out system was also calculated.^ Results. The median time required by birth registrars to complete consent procedures varied from 72-285 seconds per child. The annual costs associated with obtaining consent for 388,285 newborns in ImmTrac's opt-in consent process were estimated at $702,000. The corresponding costs of the proposed opt-out system were estimated to total $194,000 per year. ^ Conclusions. Substantial variation in the time and costs associated with completion of ImmTrac consent procedures were observed. Changing to an opt-out system for participation could represent significant cost savings. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High levels of poverty and unemployment, and low levels of health insurance coverage may pose barriers to obtaining cardiac care by Mexican Americans. We undertook this study to investigate differences in the use of invasive myocardial revascularization procedures received within the 4-month period following hospitalization for a myocardial infarction (MI) between Mexican Americans and non-Hispanic whites in the Corpus Christi Heart Project (CCHP). The CCHP is a population-based surveillance program for hospitalized MI, percutaneous transluminal coronary angioplasty (PTCA), and aortocoronary bypass surgery (ACBS). Medical record data were available for 1706 patients identified over a three-year period. Mexican Americans had significantly lower rates of receiving a PTCA following MI than non-Hispanic Whites (RR: 0.56, 95% CI: 0.44-0.70). No meaningful ethnic difference was seen in the rates of ACBS use. History of PTCA use appeared to interact with ethnicity. Among patients without a history of PTCA use, Mexican Americans were less likely to receive a PTCA than non-Hispanic whites (RR: 0.59; 95% CI: 0.46-0.76). Among patients with a history of PTCA use, however, Mexican Americans were more likely to receive a PTCA than non-Hispanic whites (RR: 1.47; 95% CI: 0.75-2.87).^ Differences in the effectiveness of a first-time PTCA and first-time ACBS between Mexican Americans and non-Hispanic whites in the CCHP were also investigated. Mexican Americans were more likely to receive a 2nd PTCA (RR: 1.56, 95% CI: 1.11-2.17) and suffer a subsequent MI (RR: 1.42, 95% CI: 1.03-1.96) following a first-time PTCA than non-Hispanic whites. No meaningful ethnic differences were found in the rates of death and rates of ACBS following a first-time PTCA. Also, no significant ethnic differences were found in the rates of any of the events following a first-time ACBS. After adjusting for potential demographic, socioeconomic, clinical and angiographic confounders using Cox regression analysis, Mexican Americans were still more likely to receive a 2nd PTCA (HR: 1.38; 95% CI: 0.99-1.93) following a first-time PTCA than non-Hispanic whites. A significant difference in the rates of a subsequent MI following a first-time PTCA persisted (HR: 1.39, 95% CI: 1.01-1.93). (Abstract shortened by UMI.) ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conservative procedures in low-dose risk assessment are used to set safety standards for known or suspected carcinogens. However, the assumptions upon which the methods are based and the effects of these methods are not well understood.^ To minimize the number of false-negatives and to reduce the cost of bioassays, animals are given very high doses of potential carcinogens. Results must then be extrapolated to much smaller doses to set safety standards for risks such as one per million. There are a number of competing methods that add a conservative safety factor into these calculations.^ A method of quantifying the conservatism of these methods was described and tested on eight procedures used in setting low-dose safety standards. The results using these procedures were compared by computer simulation and by the use of data from a large scale animal study.^ The method consisted of determining a "true safe dose" (tsd) according to an assumed underlying model. If one assumed that Y = the probability of cancer = P(d), a known mathematical function of the dose, then by setting Y to some predetermined acceptable risk, one can solve for d, the model's "true safe dose".^ Simulations were generated, assuming a binomial distribution, for an artificial bioassay. The eight procedures were then used to determine a "virtual safe dose" (vsd) that estimates the tsd, assuming a risk of one per million. A ratio R = ((tsd-vsd)/vsd) was calculated for each "experiment" (simulation). The mean R of 500 simulations and the probability R $<$ 0 was used to measure the over and under conservatism of each procedure.^ The eight procedures included Weil's method, Hoel's method, the Mantel-Byran method, the improved Mantel-Byran, Gross's method, fitting a one-hit model, Crump's procedure, and applying Rai and Van Ryzin's method to a Weibull model.^ None of the procedures performed uniformly well for all types of dose-response curves. When the data were linear, the one-hit model, Hoel's method, or the Gross-Mantel method worked reasonably well. However, when the data were non-linear, these same methods were overly conservative. Crump's procedure and the Weibull model performed better in these situations. ^