11 resultados para Evaluation of multiple intelligences
em DigitalCommons@The Texas Medical Center
Resumo:
Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter. Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and lesions (2:1, 5:1, 10:1 lesion-to-background ratios). The overall error was calculated from ROI measurements in the phantoms with a clinically relevant background activity concentration (0.065 μCi/cc). The error due to count rate effects was determined by comparing the overall error at multiple background activity concentrations to the error at 0.007 μCi/cc. A point source and cold gelatin phantoms were used to assess the errors due to attenuation and scatter. The maximum pixel values in gelatin and in air were compared to determine the effect of attenuation. Scatter was evaluated by comparing the sum of all pixel values in gelatin and in air. Results: The overall error in the background was found to be negative in phantoms of all thicknesses, with the exception of the 4-cm thick phantoms (0%±7%), and it increased with thickness (-34%±6% for the 12-cm phantoms). All lesions exhibited large negative error (-22% for the 2:1 lesions in the 4-cm phantom) which increased with thickness and with lesion-to-background ratio (-85% for the 10:1 lesions in the 12-cm phantoms). The error due to count rate in phantoms with 0.065 μCi/cc background was negative (-23%±6% for 4-cm thickness) and decreased with thickness (-7%±7% for 12 cm). Attenuation was a substantial source of negative error and increased with thickness (-51%±10% to -77% ±4% in 4 to 12 cm phantoms, respectively). Scatter contributed a relatively constant amount of positive error (+23%±11%) for all thicknesses. Conclusion: Applying corrections for count rate, attenuation and scatter will be essential for the PEM Flex Solo II to be able to produce quantitatively accurate images.
Resumo:
Neural tube defects (NTDs) are the most common severely disabling birth defects in the United States, with a frequency of approximately 1–2 of every 1,000 births. This text includes the identification and evaluation of candidate susceptibility genes that confer risk for the development of neural tube defects (NTDs). The project focused on isolated meningomyelocele, also termed spina bifida (SB). ^ Spina bifida is a complex disease with multifactorial inheritance, therefore the subject population (consisting of North American Caucasians and Hispanics of Mexicali-American descent) was composed of 459 simplex SB families who were tested for genetic associations utilizing the transmission disequilibrium test (TDT), a nonparametric linkage technique. Three categories of candidate genes were studied, including (1) human equivalents of genes determined in mouse models to cause NTDs, (2) HOX and PAX genes, and (3) the MTHFR gene involved in the metabolic pathway of folate. ^ The C677T variant of the 5,10-methylenetetrahydrofolate reductase (MTHFR) gene was the first mutation in this gene to be implicated as a risk factor for NTDs. Our evaluation of the MTHFR gene provides evidence that maternal C677T homozygosity is a risk factor for upper level spina bifida defects in Hispanics [OR = 2.3, P = 0.02]. This observed risk factor is of great importance due to the high prevalence of this homozygous genotype in the Hispanic population. Additionally, maternal C677T/A1298C compound heterozygosity is a risk factor for upper level spina bifida defects in non-Hispanic whites [OR = 3.6, P = 0.03]. ^ For TDT analysis, our total population of 1128 subjects were genotyped for 54 markers from within and/or flanking the 20 candidate genes/gene regions of interest. Significant TDT findings were obtained for 3 of the 54 analyzed markers: d20s101 flanking the PAX1 gene (P = 0.019), d1s228 within the PAX7 gene (P = 0.011), and d2s110 within the PAX8 gene (P = 0.013). These results were followed-up by testing the genes directly for mutations utilizing single-strand conformational analysis (SSCA) and direct sequencing. Multiple variations were detected in each of these PAX genes; however, these variations were not passed from parent to child in phase with the positively transmitted alleles. Therefore, these variations do not contribute to the susceptibility of spina bifida, but rather are previously unreported single nucleotide polymorphisms. ^
Resumo:
Despite of the proven efficacy of the Pap test, Asian populations still have low Pap screening compliance. The purpose of this dissertation was to investigate factors that influencing women's decision to obtain a Pap test, and to describe the development and evaluation of a cervical cancer educational program promoting the Pap screening behavior among women in Taiwan. ^ The first study examined factors associated with Pap screening compliance. Psychometric properties of measurement instruments were also assessed. The scale reliabilities were as the follows: Cronbach alpha 0.70 for knowledge scale, 0.88 for pros scale, 0.68 for cons scale, and 0.72 for perceived norms scale. Results from multiple logistic regression analysis, after adjusted for marital status, showed women who compliant to Pap screening guidelines had significantly higher knowledge, higher perceived benefits (pros), lower perceived barriers (cons), and higher perceived norms to receive a Pap test. ^ The second study described the development of a program called “Love yourself before you take care of your family”, designed to increase Pap screening behavior among women in Taiwan. The development of this program was guided by Intervention Mapping (IM), an innovative process of intervention design. The program used methods such as information transmission, modeling, persuasion, and facilitation. Strategies included direct mail campaigns, role model stories with women's testimonials, and phone intervention. ^ The third study examined the effectiveness of a randomized trial of the carefully-designed intervention (N = 424). Participants were female family members of inpatients admitted to one of the major teaching hospitals in Taiwan during August and September 1999. Women in the intervention group reported a higher rate of receiving a Pap test than women in the control group (50% versus 32%) after a three-month intervention (p = 0.002). Women in the intervention group showed increased knowledge (p = .016), perceived pros (p = 0.008), and susceptibility (p = .011) between baseline and follow-up. They also showed higher perceived pros of Pap tests than women in control group at follow-up (p = .031). This result suggested that program development based on theories and evidences could maximize the intervention impact for a specific target population. ^
Resumo:
Dental caries is a common preventable childhood disease leading to severe physical, mental and economic repercussions for children and their families if left untreated. A needs assessment in Harris County reported that 45.9% of second graders had untreated dental caries. In order to address this growing problem, the School Sealant Program (SSP), a primary preventive initiative, was launched by the Houston Department of Health and Human Services (HDHHS) to provide oral health education, and underutilized dental preventive services to second grade children from participating Local School Districts (LSDs). ^ To determine the effectiveness and efficiency of the SSP, a program evaluation was conducted by the HDHHS between September 2007 and June 2008 for the Oral Health Education (OHE) component of the SSP. The objective of the evaluation was to assess short term changes in oral health knowledge of the participants and determine if these changes, if any, were due to the OHE sessions. An 8-item multiple choice pre/post test was developed for this purpose and administered to the participants before and immediately after the OHE sessions. ^ The present project analyzed pre and post test data of 1,088 second graders from 22 participating schools. Changes in overall and topic-specific knowledge of the program participants before and after the OHE sessions were analyzed using the Wilcoxon's signed rank test. ^ Results. The overall knowledge assessment showed a statistically significant (p <0.001) increase in the dental health knowledge of the participants after the oral health education sessions. Participants in the higher scoring category (7-8 correct responses) increased from 9.5% at baseline to 60.8% after the education sessions. Overall knowledge increased in all school regions with the highest knowledge gains seen in the Central and South regions. Males and females had similar knowledge gains. Significant knowledge differences were also found for each of the topic specific categories (functions of teeth, healthy diet, healthy habits, dental sealants; p<0.001) indicating an increase in topic specific knowledge of the participants post-health education sessions. ^ Conclusions. The OHE sessions were successful in increasing the short term oral health knowledge of the participants. ^
Resumo:
Cardiovascular disease has been the leading cause of death in the United States for over fifty years. While multiple risk factors for cardiovascular disease have been identified, hypertension is one of the most commonly recognized and treatable. Recent studies indicate that the prevalence of hypertension among children and adolescents is between 3-5%, much higher than originally estimated and likely rising due to the epidemic of obesity in the U.S. In 2004, the National High Blood Pressure Education Program Working Group on High Blood Pressure in Children and Adolescents published new guidelines for the diagnosis and treatment of hypertension in this population. Included in these recommendations was the creation of a new diagnosis, pre-hypertension, aimed at identifying children at-risk for hypertension to provide early lifestyle interventions in an effort to prevent its ultimate development. In order to determine the risk associated with pre-hypertension for the development of incident HTN, a secondary analysis of a repeated cross-sectional study measuring blood pressure in Houston area adolescents from 2000 to 2007 was performed. Of 1006 students participating in the blood pressure screening on more than one occasion not diagnosed with hypertension at initial encounter, eleven were later found to have hypertension providing an overall incident rate of 0.5% per year. Incidence rates were higher among overweight adolescents–1.9% per year [IRR 8.6 (1.97, 51.63)]; students “at-risk for hypertension” (pre-hypertensive or initial blood pressure in the hypertensive range but falling on subsequent measures)–1.4% per year [IRR 4.77 (1.21, 19.78)]; and those with blood pressure ≥90th percentile on three occasions–6.6% per year [IRR 21.87 (3.40, 112.40)]. Students with pre-hypertension as currently defined by the Task Force did have an increased rate of hypertension (1.1% per year) but it did not reach statistical significance [IRR 2.44 (0.42, 10.18)]. Further research is needed to determine the morbidity and mortality associated with pre-hypertension in this age group as well as the effectiveness of various interventions for preventing the development of hypertensive disease among these at-risk individuals. ^
Resumo:
Objective. To examine and evaluate racial and ethnic disparities in glycemic control among HRS respondents with diabetes aged 55-94 years. ^ Methods. The HRS Diabetes 2003 database provides data on blood-drawn glycemic control and self-reported demographics, socioeconomic status, clinical, health access and self-care characteristics. 1,141 non-Hispanic White, non-Hispanic Black, and Hispanic respondents were included in multiple logistic regression of glycemic control. ^ Results. The rate of poor control was significantly higher among Blacks (61.5%, 105/171) and Hispanics (65.3% 72/110) than among Whites (45.0% 387/860) (p < 0.01). After controlling for influential covariates and interactions, Blacks and Hispanics had a three-fold increased risk for poor control compared to Whites when duration was five years or less. ^ Conclusions. Clinical and self-perception variables, like duration, medication, and self-rated poor diabetes control affected glycemic control independent of race and ethnicity, but there remains unexplained racial and ethnic disparities for newly-diagnosed individuals. This is the first study to find an interaction between duration and race and ethnicity on glycemic control. Future research should incorporate cultural beliefs and attitudes about diabetes control that may explain the racial and ethnic disparity. ^
Resumo:
Refugee populations suffer poor health status and yet the activities of refugee relief agencies in the public health sector have not been subjected previously to comprehensive evaluation. The purpose of this study was to examine the effectiveness and cost of the major public health service inputs of the international relief operation for Indochinese refugees in Thailand coordinated by the United Nations High Commissioner for Refugees (UNHCR). The investigator collected data from surveillance reports and agency records pertaining to 11 old refugee camps administered by the Government of Thailand Ministry of Interior (MOI) since an earlier refugee influx, and five new Khmer holding centers administered directly by UNHCR, from November, 1979, to March, 1982.^ Generous international funding permitted UNHCR to maintain a higher level of public health service inputs than refugees usually enjoyed in their countries of origin or than Thais around them enjoyed. Annual per capita expenditure for public health inputs averaged approximately US$151. Indochinese refugees in Thailand, for the most part, had access to adequate general food rations, to supplementary feeding programs, and to preventive health measures, and enjoyed high-quality medical services. Old refugee camps administered by MOI consistently received public health inputs of lower quantity and quality compared with new UNHCR-administered holding centers, despite comparable per capita expenditure after both types of camps had stabilized (static phase).^ Mortality and morbidity rates among new Khmer refugees were catastrophic during the emergency and transition phases of camp development. Health status in the refugee population during the static phase, however, was similar to, or better than, health status in the refugees' countries of origin or the Thai communities surrounding the camps. During the static phase, mortality and morbidity generally remained stable at roughly the same low levels in both types of camps.^ Furthermore, the results of multiple regression analyses demonstrated that combined public health inputs accounted for from one to 23 per cent of the variation in refugee mortality and morbidity. The direction of associations between some public health inputs and specific health outcome variables demonstrated no clear pattern. ^
Resumo:
High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.
Resumo:
This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in which dosimeter response is not inhibited by oxygen, was found to make up roughly one fourth of the total dosimeter volume. Delivering a dose across multiple fractions was found to yield a greater response than delivering the same dose in a single irradiation. The dosimeter was found to accurately measure a dose distribution produced by overlapping photon fields, yielding gamma pass rates of 95.4% and 93.1% from two planar gamma analyses. Proton irradiations were performed for measurements of proton dose and LET. Initial irradiations performed through the side of a dosimeter led to OCT artifacts. Gamma pass rates of 85.7% and 89.9% were observed in two planar gamma analyses. In irradiations performed through the base of a dosimeter, gel response was found to increase with height in the dosimeter, even in areas of constant dose. After a correction was applied, gamma pass rates of 94.6% and 99.3% were observed in two planar gamma analyses. Absolute dose measurements were substantially higher (33%-100%) than the delivered doses for proton irradiations. Issues encountered while calibrating the LET-Meter gel restricted analysis of the LET measurement data to the SOBP of a proton beam. LET-Meter overresponse was found to increase linearly with track-average LET across the LET range that could be investigated (1.5 keV/micron – 3.5 keV/micron).
Resumo:
To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.
Resumo:
An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^