3 resultados para Evaluation metrics

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The healthcare industry spends billions on worker injury and employee turnover. Hospitals and healthcare settings have one of the highest rates of lost days due to injuries. The occupational hazards for healthcare workers can be classified into biological, chemical, ergonomic, physical, organizational, and psychosocial. Therefore, interventions addressing a range of occupational health risks are needed to prevent injuries and reduce turnover and reduce costs. ^ The Sacred Vocation Program (SVP) seeks to change the content of work, i.e., the meaningfulness of work, to improve work environments. The SVP intervenes at both the individual and organizational level. First the SVP attempts to connect healthcare workers with meaning from their work through a series of 5 self-discovery group sessions. In a sixth session the graduates take an oath recommitting them to do their work as a vocation. Once motivated to connect with meaning in their work, a representative employee group meets in a second set of five meetings. This representative group suggests organizational changes to create a culture that supports employees in their calling. The employees present their plan in the twelfth session to management beginning a new phase in the existing dialogue between employees and management. ^ The SVP was implemented in a large Dallas hospital (almost 1000 licensed beds). The Baylor University Medical Center (BUMC) Pastoral Care department invited front-line caregivers (primarily Patient Care Assistants, PCAs, or Patient Care Technicians, PCTs) to participate in the SVP. Participants completed SVP questionnaires at the beginning and following SVP implementation. Following implementation, employer records were collected on injury, absence and turnover to further evaluate the program's effectiveness on metrics that are meaningful to managers in assessing organizational performance. This provided an opportunity to perform an epidemiological evaluation of the intervention using the two sources of information: employee self-reports and employer administrative data. ^ The ability to evaluate the effectiveness of the SVP on program outcomes could be limited by the strength of the measures used. An ordinal CFA performed on baseline SVP questionnaire measurements examined the construct validity and reliability of the SVP scales. Scales whose item-factor structure was confirmed in ordinal CFA were evaluated for their psychometric properties (i.e., reliability, mean, ceiling and floor effects). CFA supported the construct validity of six of the proposed scales: blocks to spirituality, meaning at work, work satisfaction, affective commitment, collaborative communication, and MHI-5. Five of the six scales confirmed had acceptable measures of reliability (all but MHI-5 had α>0.7). All six scales had a high percentage (>30%) of the scores at the ceiling. These findings supported the use of these items in the evaluation of change although strong ceiling effects may hinder discerning change. ^ Next, the confirmed SVP scales were used to evaluate whether the intervention improved program constructs. To evaluate the SVP a one group pretest-posttest design compared participants’ self-reports before and after the intervention. It was hypothesized that measurements of reduced blocks to spirituality (α = 0.76), meaning at work (α = 0.86), collaborative communication (α = 0.67) and SVP job tasks (α = 0.97) would improve following SVP implementation. The SVP job tasks scale was included even though it was not included in the ordinal CFA analysis due to a limited sample and high inter-item correlation. Changes in scaled measurements were assessed using multilevel linear regression methods. All post-intervention measurements increased (increases <0.28 points) but only reduced blocks to spirituality was statistically significant (0.22 points on a scale from 1 to 7, p < 0.05) after adjustment for covariates. Intensity of the intervention (stratifying on high participation units) strengthened effects; but were not statistically significant. The findings provide preliminary support for the hypothesis that meaning in work can be improved and, importantly, lend greater credence to any observed improvements in the outcomes. (Abstract shortened by UMI.)^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.