12 resultados para Error

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces an extended hierarchical task analysis (HTA) methodology devised to evaluate and compare user interfaces on volumetric infusion pumps. The pumps were studied along the dimensions of overall usability and propensity for generating human error. With HTA as our framework, we analyzed six pumps on a variety of common tasks using Norman’s Action theory. The introduced method of evaluation divides the problem space between the external world of the device interface and the user’s internal cognitive world, allowing for predictions of potential user errors at the human-device level. In this paper, one detailed analysis is provided as an example, comparing two different pumps on two separate tasks. The results demonstrate the inherent variation, often the cause of usage errors, found with infusion pumps being used in hospitals today. The reported methodology is a useful tool for evaluating human performance and predicting potential user errors with infusion pumps and other simple medical devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Is the solution for medical errors medical or cognitive? In this AMIA2001 panel on medical error, we argued that medical error is primarily an issue for cognitive science and engineering, not for medicine, although the knowledge of the practice of medicine is essential for the research and prevention of medical errors. The three panelists presented studies that demonstrate that cognitive research is the foundation for theories of medical errors and interventions of error reductions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Healthcare has been slow in using human factors principles to reduce medical errors. The Center for Devices and Radiological Health (CDRH) recognizes that a lack of attention to human factors during product development may lead to errors that have the potential for patient injury, or even death. In response to the need for reducing medication errors, the National Coordinating Council for Medication Errors Reporting and Prevention (NCC MERP) released the NCC MERP taxonomy that provides a standard language for reporting medication errors. This project maps the NCC MERP taxonomy of medication error to MedWatch medical errors involving infusion pumps. Of particular interest are human factors associated with medical device errors. The NCC MERP taxonomy of medication errors is limited in mapping information from MEDWATCH because of the focus on the medical device and the format of reporting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is becoming clear that if we are to impact the rate of medical errors it will have to be done at the practicing physician level. The purpose of this project was to survey the attitude of physicians in Alabama concerning their perception of medical error, and to obtain their thoughts and desires for medical education in the area of medical errors. The information will be used in the development of a physician education program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to investigate the effects of predictor variable correlations and patterns of missingness with dichotomous and/or continuous data in small samples when missing data is multiply imputed. Missing data of predictor variables is multiply imputed under three different multivariate models: the multivariate normal model for continuous data, the multinomial model for dichotomous data and the general location model for mixed dichotomous and continuous data. Subsequent to the multiple imputation process, Type I error rates of the regression coefficients obtained with logistic regression analysis are estimated under various conditions of correlation structure, sample size, type of data and patterns of missing data. The distributional properties of average mean, variance and correlations among the predictor variables are assessed after the multiple imputation process. ^ For continuous predictor data under the multivariate normal model, Type I error rates are generally within the nominal values with samples of size n = 100. Smaller samples of size n = 50 resulted in more conservative estimates (i.e., lower than the nominal value). Correlation and variance estimates of the original data are retained after multiple imputation with less than 50% missing continuous predictor data. For dichotomous predictor data under the multinomial model, Type I error rates are generally conservative, which in part is due to the sparseness of the data. The correlation structure for the predictor variables is not well retained on multiply-imputed data from small samples with more than 50% missing data with this model. For mixed continuous and dichotomous predictor data, the results are similar to those found under the multivariate normal model for continuous data and under the multinomial model for dichotomous data. With all data types, a fully-observed variable included with variables subject to missingness in the multiple imputation process and subsequent statistical analysis provided liberal (larger than nominal values) Type I error rates under a specific pattern of missing data. It is suggested that future studies focus on the effects of multiple imputation in multivariate settings with more realistic data characteristics and a variety of multivariate analyses, assessing both Type I error and power. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of the problem and public health significance. Hospitals were designed to be a safe haven and respite from disease and illness. However, a large body of evidence points to preventable errors in hospitals as the eighth leading cause of death among Americans. Twelve percent of Americans, or over 33.8 million people, are hospitalized each year. This population represents a significant portion of at risk citizens exposed to hospital medical errors. Since the number of annual deaths due to hospital medical errors is estimated to exceed 44,000, the magnitude of this tragedy makes it a significant public health problem. ^ Specific aims. The specific aims of this study were threefold. First, this study aimed to analyze the state of the states' mandatory hospital medical error reporting six years after the release of the influential IOM report, "To Err is Human." The second aim was to identify barriers to reporting of medical errors by hospital personnel. The third aim was to identify hospital safety measures implemented to reduce medical errors and enhance patient safety. ^ Methods. A descriptive, longitudinal, retrospective design was used to address the first stated objective. The study data came from the twenty-one states with mandatory hospital reporting programs which report aggregate hospital error data that is accessible to the public by way of states' websites. The data analysis included calculations of expected number of medical errors for each state according to IOM rates. Where possible, a comparison was made between state reported data and the calculated IOM expected number of errors. A literature review was performed to achieve the second study aim, identifying barriers to reporting medical errors. The final aim was accomplished by telephone interviews of principal patient safety/quality officers from five Texas hospitals with more than 700 beds. ^ Results. The state medical error data suggests vast underreporting of hospital medical errors to the states. The telephone interviews suggest that hospitals are working at reducing medical errors and creating safer environments for patients. The literature review suggests the underreporting of medical errors at the state level stems from underreporting of errors at the delivery level. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medication errors, one of the most frequent types of medical errors, are a common cause of patient harm in hospital systems today. Nurses at the bedside are in a position to encounter many of these errors since they are there at the start of the process (ordering/prescribing) and the end of the process (administration). One of the recommendations from the IOM (Institute of Medicine) report, "To Err is Human," was for organizations to identify and learn from medical errors through event reporting systems. While many organizations have reporting systems in place, research studies report a significant amount of underreporting by nurses. A systematic review of the literature was performed to identify contributing factors related to the reporting and not reporting of medication errors by nurses at the bedside.^ Articles included in the literature review were primary or secondary studies, dated January 1, 2000 – July 2009, related to nursing medication error reporting. All 634 articles were reviewed with an algorithm developed to standardize the review process and help filter out those that did not meet the study criteria. In addition, 142 article bibliographies were reviewed to find additional studies that were not found in the original literature search.^ After reviewing the 634 articles and the additional 108 articles discovered in the bibliography review, 41 articles met the study criteria and were used in the systematic literature review results.^ Fear of punitive reactions to medication errors was a frequent barrier to error reporting. Nurses fear reactions from their leadership, peers, patients and their families, nursing boards, and the media. Anonymous reporting systems and departments/organizations with a strong safety culture in place helped to encourage the reporting of medication errors by nursing staff.^ Many of the studies included in this literature review do not allow results that can be generalized. The majority of them took place in single institutions/organizations with limited sample sizes. Stronger studies with larger sample sizes need to be performed, utilizing data collection methods that have been validated, to determine stronger correlations between safety cultures and nurse error reporting.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Over 39.9% of the adult population forty or older in the United States has refractive error, little is known about the etiology of this condition and associated risk factors and their entailed mechanism due to the paucity of data regarding the changes of refractive error for the adult population over time.^ Aim. To evaluate risk factors over a long term, 5-year period, in refractive error changes among persons 43 or older by testing the hypothesis that age, gender, systemic diseases, nuclear sclerosis and baseline refractive errors are all significantly associated with refractive errors changes in patients at a Dallas, Texas private optometric office.^ Methods. A retrospective chart review of subjective refraction, eye health, and self-report health history was done on patients at a private optometric office who were 43 or older in 2000 who had eye examinations both in 2000 and 2005. Aphakic and pseudophakic eyes were excluded as well as eyes with best corrected Snellen visual acuity of 20/40 and worse. After exclusions, refraction was obtained on 114 right eyes and 114 left eyes. Spherical equivalent (sum of sphere + ½ cylinder) was used as the measure of refractive error.^ Results. Similar changes in refractive error were observed for the two eyes. The 5-year change in spherical power was in a hyperopic direction for younger age groups and in a myopic direction for older subjects, P<0.0001. The gender-adjusted mean change in refractive error in right eyes of persons aged 43 to 54, 55 to 64, 65 to 74, and 75 or older at baseline was +0.43D, +0.46 D, -0.09 D, and -0.23D, respectively. Refractive change was strongly related to baseline nuclear cataract severity; grades 4 to 5 were associated with a myopic shift (-0.38 D, P< 0.0001). The mean age-adjusted change in refraction was +0.27 D for hyperopic eyes, +0.56 D for emmetropic eyes, and +0.26 D for myopic eyes.^ Conclusions. This report has documented refractive error changes in an older population and confirmed reported trends of a hyperopic shift before age 65 and a myopic shift thereafter associated with the development of nuclear cataract.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Each year, hospitalized patients experience 1.5 million preventable injuries from medication errors and hospitals incur an additional $3.5 billion in cost (Aspden, Wolcott, Bootman, & Cronenwatt; (2007). It is believed that error reporting is one way to learn about factors contributing to medication errors. And yet, an estimated 50% of medication errors go unreported. This period of medication error pre-reporting, with few exceptions, is underexplored. The literature focuses on error prevention and management, but lacks a description of the period of introspection and inner struggle over whether to report an error and resulting likelihood to report. Reporting makes a nurse vulnerable to reprimand, legal liability, and even threat to licensure. For some nurses this state may invoke a disparity between a person‘s belief about him or herself as a healer and the undeniable fact of the error.^ This study explored the medication error reporting experience. Its purpose was to inform nurses, educators, organizational leaders, and policy-makers about the medication error pre-reporting period, and to contribute to a framework for further investigation. From a better understanding of factors that contribute to or detract from the likelihood of an individual to report an error, interventions can be identified to help the nurse come to a psychologically healthy resolution and help increase reporting of error in order to learn from error and reduce the possibility of future similar error.^ The research question was: "What factors contribute to a nurse's likelihood to report an error?" The specific aims of the study were to: (1) describe participant nurses' perceptions of medication error reporting; (2) describe participant explanations of the emotional, cognitive, and physical reactions to making a medication error; (3) identify pre-reporting conditions that make it less likely for a nurse to report a medication error; and (4) identify pre-reporting conditions that make it more likely for a nurse to report a medication error.^ A qualitative research study was conducted to explore the medication error experience and in particular the pre-reporting period from the perspective of the nurse. A total of 54 registered nurses from a large private free-standing not-for-profit children's hospital in the southwestern United States participated in group interviews. The results describe the experience of the nurse as well as the physical, emotional, and cognitive responses to the realization of the commission of a medication error. The results also reveal factors that make it more and less likely to report a medication error.^ It is clear from this study that upon realization that he or she has made a medication error, a nurse's foremost concern is for the safety of the patient. Fear was also described by each group of nurses. The nurses described a fear of several things including physician reaction, manager reaction, peer reaction, as well as family reaction and possible lack of trust as a result. Another universal response was the description of a struggle with guilt, shame, imperfection, blaming oneself, and questioning one's competence.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In regression analysis, covariate measurement error occurs in many applications. The error-prone covariates are often referred to as latent variables. In this proposed study, we extended the study of Chan et al. (2008) on recovering latent slope in a simple regression model to that in a multiple regression model. We presented an approach that applied the Monte Carlo method in the Bayesian framework to the parametric regression model with the measurement error in an explanatory variable. The proposed estimator applied the conditional expectation of latent slope given the observed outcome and surrogate variables in the multiple regression models. A simulation study was presented showing that the method produces estimator that is efficient in the multiple regression model, especially when the measurement error variance of surrogate variable is large.^