15 resultados para Electronic technicians
em DigitalCommons@The Texas Medical Center
Resumo:
The "EMR Tutorial" is designed to be a bilingual online physician education environment about electronic medical records. After iterative assessment and redesign, the tutorial was tested in two groups: U.S. physicians and Mexican medical students. Split-plot ANOVA revealed significantly different pre-test scores in the two groups, significant cognitive gains for the two groups overall, and no significant difference in the gains made by the two groups. Users rated the module positively on a satisfaction questionnaire.
Resumo:
BACKGROUND: We have carried out an extensive qualitative research program focused on the barriers and facilitators to successful adoption and use of various features of advanced, state-of-the-art electronic health records (EHRs) within large, academic, teaching facilities with long-standing EHR research and development programs. We have recently begun investigating smaller, community hospitals and out-patient clinics that rely on commercially-available EHRs. We sought to assess whether the current generation of commercially-available EHRs are capable of providing the clinical knowledge management features, functions, tools, and techniques required to deliver and maintain the clinical decision support (CDS) interventions required to support the recently defined "meaningful use" criteria. METHODS: We developed and fielded a 17-question survey to representatives from nine commercially available EHR vendors and four leading internally developed EHRs. The first part of the survey asked basic questions about the vendor's EHR. The second part asked specifically about the CDS-related system tools and capabilities that each vendor provides. The final section asked about clinical content. RESULTS: All of the vendors and institutions have multiple modules capable of providing clinical decision support interventions to clinicians. The majority of the systems were capable of performing almost all of the key knowledge management functions we identified. CONCLUSION: If these well-designed commercially-available systems are coupled with the other key socio-technical concepts required for safe and effective EHR implementation and use, and organizations have access to implementable clinical knowledge, we expect that the transformation of the healthcare enterprise that so many have predicted, is achievable using commercially-available, state-of-the-art EHRs.
Resumo:
BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.
Resumo:
BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.
Resumo:
BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.
Resumo:
The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^
Resumo:
Background. The number of infections of cardiac implantable electronic devices (CIED) continues to escalate out of proportion to the increase rate of device implantation. Staphylococcal organisms account for 70% to 90% of all CIED infections. However, little is known about non-staphylococcal infections, which have been described only in case reports, small case series or combined in larger studies with staphylococcal CIED infections, thereby diluting their individual impact. ^ Methods. A retrospective review of hospital records of patients admitted with a CIED-related infections were identified within four academic hospitals in Houston, Texas between 2002 and 2009. ^ Results. Of the 504 identified patients with CIED-related infection, 80 (16%) had a non-staphylococcal infection and were the focus of this study. Although the demographics and comorbities of subjects were comparable to other reports, our study illustrates many key points: (a) the microbiologic diversity of non-staphylococcal infections was rather extensive, as it included other Gram-positive bacteria like streptococci and enterococci, a variety of Gram-negative bacteria, atypical bacteria including Nocardia and Mycobacteria, and fungi like Candida and Aspergillus; (b) the duration of CIED insertion prior to non-staphylococcal infection was relatively prolong (mean, 109 ± 27 weeks), of these 44% had their device previously manipulated within a mean of 29.5 ± 6 weeks; (c) non-staphylococcal organisms appear to be less virulent, cause prolonged clinical symptoms prior to admission (mean, 48 ± 12.8 days), and are associated with a lower mortality (4%) than staphylococcal organisms; (d) thirteen patients (16%) presented with CIED-related endocarditis; (e) although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteremia seeding of the CIED; and (f) inappropriate antimicrobial coverage was provided in approximately 50% of patients with non-staphylococcal infections for a mean period of 2.1 days. ^ Conclusions. Non-staphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Since non-staphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. Additionally, in patients with suspected CIED infection, adequate Gram positive and -negative antibacterial coverage should be administered until microbiologic data become available.^
Resumo:
Identifying accurate numbers of soldiers determined to be medically not ready after completing soldier readiness processing may help inform Army leadership about ongoing pressures on the military involved in long conflict with regular deployment. In Army soldiers screened using the SRP checklist for deployment, what is the prevalence of soldiers determined to be medically not ready? Study group. 15,289 soldiers screened at all 25 Army deployment platform sites with the eSRP checklist over a 4-month period (June 20, 2009 to October 20, 2009). The data included for analysis included age, rank, component, gender and final deployment medical readiness status from MEDPROS database. Methods.^ This information was compiled and univariate analysis using chi-square was conducted for each of the key variables by medical readiness status. Results. Descriptive epidemiology Of the total sample 1548 (9.7%) were female and 14319 (90.2%) were male. Enlisted soldiers made up 13,543 (88.6%) of the sample and officers 1,746 (11.4%). In the sample, 1533 (10.0%) were soldiers over the age of 40 and 13756 (90.0%) were age 18-40. Reserve, National Guard and Active Duty made up 1,931 (12.6%), 2,942 (19.2%) and 10,416 (68.1%) respectively. Univariate analysis. Overall 1226 (8.0%) of the soldiers screened were determined to be medically not ready for deployment. Biggest predictive factor was female gender OR (2.8; 2.57-3.28) p<0.001. Followed by enlisted rank OR (2.01; 1.60-2.53) p<0.001. Reserve component OR (1.33; 1.16-1.53) p<0.001 and Guard OR (0.37; 0.30-0.46) p<0.001. For age > 40 demonstrated OR (1.2; 1.09-1.50) p<0.003. Overall the results underscore there may be key demographic groups relating to medical readiness that can be targeted with programs and funding to improve overall military medical readiness.^
Resumo:
Information technology (IT) in the hospital organization is fast becoming a key asset, particularly in light of recent reform legislation in the United States calling for expanding the role of IT in our health care system. Future payment reductions to hospitals included in current health reform are based on expected improvements in hospital operating efficiency. Since over half of hospital expenses are for labor, improved efficiency in use of labor resources can be critical in meeting this challenge. Policy makers have touted the value of IT investments to improve efficiency in response to payment reductions. ^ This study was the first to directly examine the relationship between electronic health record (EHR) technology and staffing efficiency in hospitals. As the hospital has a myriad of outputs for inpatient and outpatient care, efficiency was measured using an industry standard performance metric – full time equivalent employees per adjusted occupied bed (FTE/AOB). Three hypotheses were tested in this study.^ To operationalize EHR technology adoption, we developed three constructs to model adoption, each of which was tested by separate hypotheses. The first hypothesis that a larger number of EHR applications used by a hospital would be associated with greater staffing efficiency (or lower values of FTE/AOB) was not accepted. Association between staffing efficiency and specific EHR applications was the second hypothesis tested and accepted with some applications showing significant impacts on observed values for FTE/AOB. Finally, the hypothesis that the longer an EHR application was used in a hospital would be associated with greater labor efficiency was not accepted as the model showed few statistically significant relationships to FTE/AOB performance. Generally, there does not appear a strong relationship between EHR usage and improved labor efficiency in hospitals.^ While returns on investment from EHR usage may not come from labor efficiencies, they may be better sought using measures of quality, contribution to an efficient and effective local health care system, and improved customer satisfaction through greater patient throughput.^