5 resultados para Electronic portal imaging device

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Autofluorescence imaging is used widely for diagnostic evaluation of various epithelial malignancies. Cancerous lesions display loss of autofluorescence due to malignant changes in epithelium and subepithelial stroma. Carcinoma of unknown primary site presents with lymph node or distant metastasis, for which the site of primary tumour is not detectable. We describe here the use of autofluorescence imaging for detecting a clinically innocuous appearing occult malignancy of the palate which upon pathological examination was consistent with a metastatic squamous cell carcinoma. CASE DESCRIPTION: A submucosal nodule was noted on the right posterior hard palate of a 59-year-old white female during clinical examination. Examination of this lesion using a multispectral oral cancer screening device revealed loss of autofluorescence at 405 nm illumination. An excisional biopsy of this nodule, confirmed the presence of a metastatic squamous cell carcinoma. Four years ago, this patient was diagnosed with metastatic squamous cell carcinoma of the right mid-jugular lymph node of unknown primary. She was treated with external beam irradiation and remained disease free until current presentation. CONCLUSION: This case illustrates the important role played by autofluorescence tissue imaging in diagnosing a metastatic palatal tumour that appeared clinically innocuous and otherwise would not have been biopsied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Investigations into the shortcomings of current intracavitary brachytherapy (ICBT) technology has lead us to design an Anatomically Adaptive Applicator (A3). The goal of this work was to design and characterize the imaging and dosimetric capabilities of this device. The A3 design incorporates a single shield that can both rotate and translate within the colpostat. We hypothesized that this feature, coupled with specific A3 component construction materials and imaging techniques, would facilitate artifact-free CT and MR image acquisition. In addition, by shaping the delivered dose distribution via the A3 movable shield, dose delivered to the rectum will be less compared to equivalent treatments utilizing current state-of-the-art ICBT applicators. ^ Method and materials. A method was developed to facilitate an artifact-free CT imaging protocol that used a "step-and-shoot" technique: pausing the scanner midway through the scan and moving the A 3 shield out of the path of the beam. The A3 CT imaging capabilities were demonstrated acquiring images of a phantom that positioned the A3 and FW applicators in a clinically-applicable geometry. Artifact-free MRI imaging was achieved by utilizing MRI-compatible ovoid components and pulse-sequences that minimize susceptibility artifacts. Artifacts were qualitatively compared, in a clinical setup. For the dosimetric study, Monte-Carlo (MC) models of the A3 and FW (shielded and unshielded) applicators were validated. These models were incorporated into a MC model of one cervical cancer patient ICBT insertion, using 192Ir (mHDR v2 source). The A3 shield's rotation and translation was adjusted for each dwell position to minimize dose to the rectum. Superposition of dose to rectum for all A3 dwell sources (4 per ovoid) was applied to obtain a comparison of equivalent FW treatments. Rectal dose-volume histograms (absolute and HDR/PDR biologically effective dose (BED)) and BED to 2 cc (BED2cc ) were determined for all applicators and compared. ^ Results. Using a "step-and-shoot" CT scanning method and MR compliant materials and optimized pulse-sequences, images of the A 3 were nearly artifact-free for both modalities. The A3 reduced BED2cc by 18.5% and 7.2% for a PDR treatment and 22.4% and 8.7% for a HDR treatment compared to treatments delivered using an uFW and sFW applicator, respectively. ^ Conclusions. The novel design of the A3 facilitated nearly artifact-free image quality for both CT and MR clinical imaging protocols. The design also facilitated a reduction in BED to the rectum compared to equivalent ICBT treatments delivered using current, state-of-the-art applicators. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. The number of infections of cardiac implantable electronic devices (CIED) continues to escalate out of proportion to the increase rate of device implantation. Staphylococcal organisms account for 70% to 90% of all CIED infections. However, little is known about non-staphylococcal infections, which have been described only in case reports, small case series or combined in larger studies with staphylococcal CIED infections, thereby diluting their individual impact. ^ Methods. A retrospective review of hospital records of patients admitted with a CIED-related infections were identified within four academic hospitals in Houston, Texas between 2002 and 2009. ^ Results. Of the 504 identified patients with CIED-related infection, 80 (16%) had a non-staphylococcal infection and were the focus of this study. Although the demographics and comorbities of subjects were comparable to other reports, our study illustrates many key points: (a) the microbiologic diversity of non-staphylococcal infections was rather extensive, as it included other Gram-positive bacteria like streptococci and enterococci, a variety of Gram-negative bacteria, atypical bacteria including Nocardia and Mycobacteria, and fungi like Candida and Aspergillus; (b) the duration of CIED insertion prior to non-staphylococcal infection was relatively prolong (mean, 109 ± 27 weeks), of these 44% had their device previously manipulated within a mean of 29.5 ± 6 weeks; (c) non-staphylococcal organisms appear to be less virulent, cause prolonged clinical symptoms prior to admission (mean, 48 ± 12.8 days), and are associated with a lower mortality (4%) than staphylococcal organisms; (d) thirteen patients (16%) presented with CIED-related endocarditis; (e) although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteremia seeding of the CIED; and (f) inappropriate antimicrobial coverage was provided in approximately 50% of patients with non-staphylococcal infections for a mean period of 2.1 days. ^ Conclusions. Non-staphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Since non-staphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. Additionally, in patients with suspected CIED infection, adequate Gram positive and -negative antibacterial coverage should be administered until microbiologic data become available.^