41 resultados para Electronic Health Records (EHR)

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We have carried out an extensive qualitative research program focused on the barriers and facilitators to successful adoption and use of various features of advanced, state-of-the-art electronic health records (EHRs) within large, academic, teaching facilities with long-standing EHR research and development programs. We have recently begun investigating smaller, community hospitals and out-patient clinics that rely on commercially-available EHRs. We sought to assess whether the current generation of commercially-available EHRs are capable of providing the clinical knowledge management features, functions, tools, and techniques required to deliver and maintain the clinical decision support (CDS) interventions required to support the recently defined "meaningful use" criteria. METHODS: We developed and fielded a 17-question survey to representatives from nine commercially available EHR vendors and four leading internally developed EHRs. The first part of the survey asked basic questions about the vendor's EHR. The second part asked specifically about the CDS-related system tools and capabilities that each vendor provides. The final section asked about clinical content. RESULTS: All of the vendors and institutions have multiple modules capable of providing clinical decision support interventions to clinicians. The majority of the systems were capable of performing almost all of the key knowledge management functions we identified. CONCLUSION: If these well-designed commercially-available systems are coupled with the other key socio-technical concepts required for safe and effective EHR implementation and use, and organizations have access to implementable clinical knowledge, we expect that the transformation of the healthcare enterprise that so many have predicted, is achievable using commercially-available, state-of-the-art EHRs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Information technology (IT) in the hospital organization is fast becoming a key asset, particularly in light of recent reform legislation in the United States calling for expanding the role of IT in our health care system. Future payment reductions to hospitals included in current health reform are based on expected improvements in hospital operating efficiency. Since over half of hospital expenses are for labor, improved efficiency in use of labor resources can be critical in meeting this challenge. Policy makers have touted the value of IT investments to improve efficiency in response to payment reductions. ^ This study was the first to directly examine the relationship between electronic health record (EHR) technology and staffing efficiency in hospitals. As the hospital has a myriad of outputs for inpatient and outpatient care, efficiency was measured using an industry standard performance metric – full time equivalent employees per adjusted occupied bed (FTE/AOB). Three hypotheses were tested in this study.^ To operationalize EHR technology adoption, we developed three constructs to model adoption, each of which was tested by separate hypotheses. The first hypothesis that a larger number of EHR applications used by a hospital would be associated with greater staffing efficiency (or lower values of FTE/AOB) was not accepted. Association between staffing efficiency and specific EHR applications was the second hypothesis tested and accepted with some applications showing significant impacts on observed values for FTE/AOB. Finally, the hypothesis that the longer an EHR application was used in a hospital would be associated with greater labor efficiency was not accepted as the model showed few statistically significant relationships to FTE/AOB performance. Generally, there does not appear a strong relationship between EHR usage and improved labor efficiency in hospitals.^ While returns on investment from EHR usage may not come from labor efficiencies, they may be better sought using measures of quality, contribution to an efficient and effective local health care system, and improved customer satisfaction through greater patient throughput.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The "EMR Tutorial" is designed to be a bilingual online physician education environment about electronic medical records. After iterative assessment and redesign, the tutorial was tested in two groups: U.S. physicians and Mexican medical students. Split-plot ANOVA revealed significantly different pre-test scores in the two groups, significant cognitive gains for the two groups overall, and no significant difference in the gains made by the two groups. Users rated the module positively on a satisfaction questionnaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently more than half of Electronic Health Record (EHR) projects fail. Most of these failures are not due to flawed technology, but rather due to the lack of systematic considerations of human issues. Among the barriers for EHR adoption, function mismatching among users, activities, and systems is a major area that has not been systematically addressed from a human-centered perspective. A theoretical framework called Functional Framework was developed for identifying and reducing functional discrepancies among users, activities, and systems. The Functional Framework is composed of three models – the User Model, the Designer Model, and the Activity Model. The User Model was developed by conducting a survey (N = 32) that identified the functions needed and desired from the user’s perspective. The Designer Model was developed by conducting a systemic review of an Electronic Dental Record (EDR) and its functions. The Activity Model was developed using an ethnographic method called shadowing where EDR users (5 dentists, 5 dental assistants, 5 administrative personnel) were followed quietly and observed for their activities. These three models were combined to form a unified model. From the unified model the work domain ontology was developed by asking users to rate the functions (a total of 190 functions) in the unified model along the dimensions of frequency and criticality in a survey. The functional discrepancies, as indicated by the regions of the Venn diagrams formed by the three models, were consistent with the survey results, especially with user satisfaction. The survey for the Functional Framework indicated the preference of one system over the other (R=0.895). The results of this project showed that the Functional Framework provides a systematic method for identifying, evaluating, and reducing functional discrepancies among users, systems, and activities. Limitations and generalizability of the Functional Framework were discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Problems due to the lack of data standardization and data management have lead to work inefficiencies for the staff working with the vision data for the Lifetime Surveillance of Astronaut Health. Data has been collected over 50 years in a variety of manners and then entered into a software. The lack of communication between the electronic health record (EHR) form designer, epidemiologists, and optometrists has led to some level to confusion on the capability of the EHR system and how its forms can be designed to fit all the needs of the relevant parties. EHR form customizations or form redesigns were found to be critical for using NASA's EHR system in the most beneficial way for its patients, optometrists, and epidemiologists. In order to implement a protocol, data being collected was examined to find the differences in data collection methods. Changes were implemented through the establishment of a process improvement team (PIT). Based on the findings of the PIT, suggestions have been made to improve the current EHR system. If the suggestions are implemented correctly, this will not only improve efficiency of the staff at NASA and its contractors, but set guidelines for changes in other forms such as the vision exam forms. Because NASA is at the forefront of such research and health surveillance the impact of this management change could have a drastic improvement on the collection of and adaptability of the EHR. Accurate data collection from this 50+ year study is ongoing and is going to help current and future generations understand the implications of space flight on human health. It is imperative that the vast amount of information is documented correctly.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Throughout the United States, there are massive initiatives in place to reform healthcare through the implementation of electronic health records. The goals are to improve patient care through improved access to records, the improvement of business and reimbursement processes, streamlining of clinician workflows for increased efficiency, and reducing the variability in the delivery of patient care. [See PDF for complete abstract]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The most effective decision support systems are integrated with clinical information systems, such as inpatient and outpatient electronic health records (EHRs) and computerized provider order entry (CPOE) systems. Purpose The goal of this project was to describe and quantify the results of a study of decision support capabilities in Certification Commission for Health Information Technology (CCHIT) certified electronic health record systems. METHODS: The authors conducted a series of interviews with representatives of nine commercially available clinical information systems, evaluating their capabilities against 42 different clinical decision support features. RESULTS: Six of the nine reviewed systems offered all the applicable event-driven, action-oriented, real-time clinical decision support triggers required for initiating clinical decision support interventions. Five of the nine systems could access all the patient-specific data items identified as necessary. Six of the nine systems supported all the intervention types identified as necessary to allow clinical information systems to tailor their interventions based on the severity of the clinical situation and the user's workflow. Only one system supported all the offered choices identified as key to allowing physicians to take action directly from within the alert. Discussion The principal finding relates to system-by-system variability. The best system in our analysis had only a single missing feature (from 42 total) while the worst had eighteen.This dramatic variability in CDS capability among commercially available systems was unexpected and is a cause for concern. CONCLUSIONS: These findings have implications for four distinct constituencies: purchasers of clinical information systems, developers of clinical decision support, vendors of clinical information systems and certification bodies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical text understanding (CTU) is of interest to health informatics because critical clinical information frequently represented as unconstrained text in electronic health records are extensively used by human experts to guide clinical practice, decision making, and to document delivery of care, but are largely unusable by information systems for queries and computations. Recent initiatives advocating for translational research call for generation of technologies that can integrate structured clinical data with unstructured data, provide a unified interface to all data, and contextualize clinical information for reuse in multidisciplinary and collaborative environment envisioned by CTSA program. This implies that technologies for the processing and interpretation of clinical text should be evaluated not only in terms of their validity and reliability in their intended environment, but also in light of their interoperability, and ability to support information integration and contextualization in a distributed and dynamic environment. This vision adds a new layer of information representation requirements that needs to be accounted for when conceptualizing implementation or acquisition of clinical text processing tools and technologies for multidisciplinary research. On the other hand, electronic health records frequently contain unconstrained clinical text with high variability in use of terms and documentation practices, and without commitmentto grammatical or syntactic structure of the language (e.g. Triage notes, physician and nurse notes, chief complaints, etc). This hinders performance of natural language processing technologies which typically rely heavily on the syntax of language and grammatical structure of the text. This document introduces our method to transform unconstrained clinical text found in electronic health information systems to a formal (computationally understandable) representation that is suitable for querying, integration, contextualization and reuse, and is resilient to the grammatical and syntactic irregularities of the clinical text. We present our design rationale, method, and results of evaluation in processing chief complaints and triage notes from 8 different emergency departments in Houston Texas. At the end, we will discuss significance of our contribution in enabling use of clinical text in a practical bio-surveillance setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of the Camp For All Connection project is to facilitate access to electronic health information resources at the Camp For All facility. Setting/Participants/Resources: Camp For All is a barrier-free camp working in partnership with organizations to enrich the lives of children and adults with chronic illnesses and disabilities and their families by providing camping and retreat experiences. The camp facility is located on 206 acres in Burton, Texas. The project partners are Texas Woman's University, Houston Academy of Medicine-Texas Medical Center Library, and Camp For All. Brief Description: The Camp For All Connection project placed Internet-connected workstations at the camp's health center in the main lodge and provided training in the use of electronic health information resources. A train-the-trainer approach was used to provide training to Camp For All staff. Results/Outcome: Project workstations are being used by health care providers and camp staff for communication purposes and to make better informed health care decisions for Camp For All campers. Evaluation Method: A post-training evaluation was administered at the end of the train-the-trainer session. In addition, a series of site visits and interviews was conducted with camp staff members involved in the project. The site visits and interviews allowed for ongoing dialog between project staff and project participants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: We sought to determine maternal and neonatal outcomes by labor onset type and gestational age. STUDY DESIGN: We used electronic medical records data from 10 US institutions in the Consortium on Safe Labor on 115,528 deliveries from 2002 through 2008. Deliveries were divided by labor onset type (spontaneous, elective induction, indicated induction, unlabored cesarean). Neonatal and maternal outcomes were calculated by labor onset type and gestational age. RESULTS: Neonatal intensive care unit admissions and sepsis improved with each week of gestational age until 39 weeks (P < .001). After adjusting for complications, elective induction of labor was associated with a lower risk of ventilator use (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.28-0.53), sepsis (OR, 0.36; 95% CI, 0.26-0.49), and neonatal intensive care unit admissions (OR, 0.52; 95% CI, 0.48-0.57) compared to spontaneous labor. The relative risk of hysterectomy at term was 3.21 (95% CI, 1.08-9.54) with elective induction, 1.16 (95% CI, 0.24-5.58) with indicated induction, and 6.57 (95% CI, 1.78-24.30) with cesarean without labor compared to spontaneous labor. CONCLUSION: Some neonatal outcomes improved until 39 weeks. Babies born with elective induction are associated with better neonatal outcomes compared to spontaneous labor. Elective induction may be associated with an increased hysterectomy risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The federal government is currently developing the Nationwide Health Information Network (NHIN). Described as a “network of networks,” the NHIN seeks to provide a nationwide, interoperable health information infrastructure that will securely connect consumers with those involved in health care. As part of the national health information technology (HIT) agenda, the NHIN aims to improve individual and population health by enabling health information to follow the consumer, be available for clinical decision-making, and support important public health measures such as biosurveillance. While the NHIN promises to improve clinical care to individuals and to reduce U.S. health care system costs overall, this electronic environment presents novel challenges for protecting individually identifiable health information. A major barrier to achieving public trust in the NHIN is the development of, and adherence to, a consistent and coordinated approach to privacy and security of health information. This paper will analyze the policy framework for electronic health information exchange with the NHIN. This exercise will demonstrate that the current policy is an effective framework for achieving effective biosurveillance with the NHIN. ^