3 resultados para Electrocardiograma (ECG)

em DigitalCommons@The Texas Medical Center


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Quantitative myocardial PET perfusion imaging requires partial volume corrections. METHODS: Patients underwent ECG-gated, rest-dipyridamole, myocardial perfusion PET using Rb-82 decay corrected in Bq/cc for diastolic, systolic, and combined whole cycle ungated images. Diastolic partial volume correction relative to systole was determined from the systolic/diastolic activity ratio, systolic partial volume correction from phantom dimensions comparable to systolic LV wall thicknesses and whole heart cycle partial volume correction for ungated images from fractional systolic-diastolic duration for systolic and diastolic partial volume corrections. RESULTS: For 264 PET perfusion images from 159 patients (105 rest-stress image pairs, 54 individual rest or stress images), average resting diastolic partial volume correction relative to systole was 1.14 ± 0.04, independent of heart rate and within ±1.8% of stress images (1.16 ± 0.04). Diastolic partial volume corrections combined with those for phantom dimensions comparable to systolic LV wall thickness gave an average whole heart cycle partial volume correction for ungated images of 1.23 for Rb-82 compared to 1.14 if positron range were negligible as for F-18. CONCLUSION: Quantitative myocardial PET perfusion imaging requires partial volume correction, herein demonstrated clinically from systolic/diastolic absolute activity ratios combined with phantom data accounting for Rb-82 positron range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Cardiac tamponade can occur when a large amount of fluid, gas, singly or in combination, accumulating within the pericardium, compresses the heart causing circulatory compromise. Although previous investigators have found the 12-lead ECG to have a poor predictive value in diagnosing cardiac tamponade, very few studies have evaluated it as a follow up tool for ruling in or ruling out tamponade in patients with previously diagnosed malignant pericardial effusions. ^ Methods. 127 patients with malignant pericardial effusions at the MD Anderson Cancer Center were included in this retrospective study. While 83 of these patients had a cardiac tamponade diagnosed by echocardiographic criteria (Gold standard), 44 did not. We computed the sensitivity (Se), specificity (Sp), positive (PPV) and negative predictive values (NPV) for individual and combinations of ECG abnormalities. Individual ECG abnormalities were also entered singly into a univariate logistic regression model to predict tamponade. ^ Results. For patients with effusions of all sizes, electrical alternans had a Se, Sp, PPV and NPV of 22.61%, 97.61%, 95% and 39.25% respectively. These parameters for low voltage complexes were 55.95%, 74.44%, 81.03%, 46.37% respectively. The presence of all three ECG abnormalities had a Se = 8.33%, Sp = 100%, PPV = 100% and NPV = 35.83% while the presence of at least one of the three ECG abnormalities had a Se = 89.28%, Sp = 46.51%, PPV = 76.53%, NPV = 68.96%. For patients with effusions of all sizes electrical alternans had an OR of 12.28 (1.58–95.17, p = 0.016), while the presence of at least one ECG abnormality had an OR of 7.25 (2.9–18.1, p = 0.000) in predicting tamponade. ^ Conclusions. Although individual ECG abnormalities had low sensitivities, specificities, NPVs and PPVs with the exception of electrical alternans, the presence of at least one of the three ECG abnormalities had a high sensitivity in diagnosing cardiac tamponade. This could point to its potential use as a screening test with a correspondingly high NPV to rule out a diagnosis of tamponade in patients with malignant pericardial effusions. This could save expensive echocardiographic assessments in patients with previously diagnosed pericardial effusions. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of exercise electrocardiography (ECG) to detect latent coronary heart disease (CHD) is discouraged in apparently healthy populations because of low sensitivity. These recommendations however, are based on the efficacy of evaluation of ischemia (ST segment changes) with little regard for other measures of cardiac function that are available during exertion. The purpose of this investigation was to determine the association of maximal exercise hemodynamic responses with risk of mortality due to all-causes, cardiovascular disease (CVD), and coronary heart disease (CHD) in apparently healthy individuals. Study participants were 20,387 men (mean age = 42.2 years) and 6,234 women (mean age = 41.9 years) patients of a preventive medicine center in Dallas, TX examined between 1971 and 1989. During an average of 8.1 years of follow-up, there were 348 deaths in men and 66 deaths in women. In men, age-adjusted all-cause death rates (per 10,000 person years) across quartiles of maximal systolic blood pressure (SBP) (low to high) were: 18.2, 16.2, 23.8, and 24.6 (p for trend $<$0.001). Corresponding rates for maximal heart rate were: 28.9, 15.9, 18.4, and 15.1 (p trend $<$0.001). After adjustment for confounding variables including age, resting systolic pressure, serum cholesterol and glucose, body mass index, smoking status, physical fitness and family history of CVD, risks (and 95% confidence interval (CI)) of all-cause mortality for quartiles of maximal SBP, relative to the lowest quartile, were: 0.96 (0.70-1.33), 1.36 (1.01-1.85), and 1.37 (0.98-1.92) for quartiles 2-4 respectively. Similar risks for maximal heart rate were: 0.61 (0.44-0.85), 0.69 (0.51-0.93), and 0.60 (0.41-0.87). No associations were noted between maximal exercise rate-pressure product mortality. Similar results were seen for risk of CVD and CHD death. In women, similar trends in age-adjusted all-cause and CVD death rates across maximal SBP and heart rate categories were observed. Sensitivity of the exercise test in predicting mortality was enhanced when ECG results were evaluated together with maximal exercise SBP or heart rate with a concomitant decrease in specificity. Positive predictive values were not improved. The efficacy of the exercise test in predicting mortality in apparently healthy men and women was not enhanced by using maximal exercise hemodynamic responses. These results suggest that an exaggerated systolic blood pressure or an attenuated heart rate response to maximal exercise are risk factors for mortality in apparently healthy individuals. ^