12 resultados para Digital library

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Photography through a microscope is virtually identical to that used with an astronomical telescope. For years, the 35mm camera was the choice for microphotography, but we live in a digital camera age now. We describe a custom homemade adapter that can be fit most of the cameras and microscopes. [See PDF for complete abstract]

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The University of Texas School of Nursing at Houston and HAM-TMC Library discuss the benefits of an institutional repository, DigitalCommons, and cover initial steps to create accounts and publish to the institutions DigitalCommons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Problem: Dental radiographs generally display one or more findings/diagnoses, and are linked to a unique set of patient demographics, medical history and other findings not represented by the image. However, this information is not associated with radiographs in any type of meta format, and images are not searchable based on any clinical criteria (1,2). The purpose of this pilot study is to create an online, searchable data repository of dental radiographs to be used for patient care, teaching and research. [See PDF for complete abstract]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A digital story on (1) domestic minor sex trafficking and (2) international human trafficking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed an empirically based simulation system to create images equivalent in SNR and SPR to those that would be acquired with various possible SEDR configurations. This system uses a collection of spot collimated full-field images (SCFFIs) of an anthropomorphic chest phantom, taken at high exposure levels and rescaled in noise and intensity, then digitally collimated and combined to produce the simulated SEDR images. This system allows for the study of design trade-offs between different equalization feedback schemes and scatter rejection geometries in addition to estimating the clinical benefits of SEDR over traditional imaging techniques. Data from this simulation system has demonstrated that SEDR techniques offer potential significant improvements over currently used digital radiography techniques for chest imaging. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Surgeon General recommends preschoolers 3-5 years old accumulate 60 minutes of moderate-to-vigorous physical activity (MVPA) per day. However, there is limited data measuring physical activity (PA) and MVPA amongst this population. The purpose of this cross-sectional study is to determine the validity, reliability, and feasibility of using MVP 4 Function Walk4Life digital pedometers (MVP-4) in measuring MVPA among preschoolers using the newly modified direct observational technique, System for Observing Fitness Instruction Time-Preschool Version (SOFIT-P) as the gold standard. An ethnically diverse population of 3-5 year old underserved children were recruited from two Harris County Department of Education (HCDE) Head Start centers. For 2 days at baseline and 2 days at post-test, 75 children enrolled wore MVP-4 pedometers for approximately 6-hours per observation day and were observed using SOFIT-P during predominantly active times. Statistical analyses used Pearson "r" correlation coefficients to determine mean minutes of PA and MVPA, convergent and criterion validity, and reliability. Significance was set at p = <0.05. Feasibility was determined through process evaluation information collected during this study via observations from data collectors and teacher input. Results show mean minutes of PA and MVPA ranged between 30-42 and 11-14 minutes, respectively. Convergent validity comparing BMI percentiles with MVP-4 PA outcomes show no significance at pre-test; however, each measurement at post-test showed significance for MVPA (p = 0.0247, p = 0.0056), respectively. Criterion validity comparing percent MVPA time between SOFIT-P and MVP-4 pedometers was determined; however, results deemed insufficient due to inconsistency in observation times while using the newly developed SOFIT-P. Reliability measures show no significance at pre-test, yet show significant results for all PA outcomes at post-test (p = 0.001, p = 0.001, p = 0.0010, p = 0.003), respectively. Finally, MVP-4 pedometers lacked feasibility due to logistical barriers in design. Researchers feel the significant results at post-test are secondary to increased familiarity and more accurate placement of pedometers across time. Researchers suggest manufacturers of MVP-4 pedometers further modify the instrument for ease of use with this population, following which future studies ought to determine validity using objective measures or all-day direct observation techniques.^