8 resultados para Diagnostic techniques, respiratory system
em DigitalCommons@The Texas Medical Center
Resumo:
This study establishes the extent and relevance of bias of population estimates of prevalence, incidence, and intensity of infection with Schistosoma mansoni caused by the relative sensitivity of stool examination techniques. The population studied was Parcelas de Boqueron in Las Piedras, Puerto Rico, where the Centers for Disease Control, had undertaken a prospective community-based study of infection with S. mansoni in 1972. During each January of the succeeding years stool specimens from this population were processed according to the modified Ritchie concentration (MRC) technique. During January 1979 additional stool specimens were collected from 30 individuals selected on the basis of their mean S. mansoni egg output during previous years. Each specimen was divided into ten 1-gm aliquots and three 42-mg aliquots. The relationship of egg counts obtained with the Kato-Katz (KK) thick smear technique as a function of the mean of ten counts obtained with the MRC technique was established by means of regression analysis. Additionally, the effect of fecal sample size and egg excretion level on technique sensitivity was evaluated during a blind assessment of single stool specimen samples, using both examination methods, from 125 residents with documented S. mansoni infections. The regression equation was: Ln KK = 2.3324 + 0.6319 Ln MRC, and the coefficient of determination (r('2)) was 0.73. The regression equation was then utilized to correct the term "m" for sample size in the expression P ((GREATERTHEQ) 1 egg) = 1 - e('-ms), which estimates the probability P of finding at least one egg as a function of the mean S. mansoni egg output "m" of the population and the effective stool sample size "s" utilized by the coprological technique. This algorithm closely approximated the observed sensitivity of the KK and MRC tests when these were utilized to blindly screen a population of known parasitologic status for infection with S. mansoni. In addition, the algorithm was utilized to adjust the apparent prevalence of infection for the degree of functional sensitivity exhibited by the diagnostic test. This permitted the estimation of true prevalence of infection and, hence, a means for correcting estimates of incidence of infection. ^
Resumo:
Objective. To describe the spectrum and occurrence of occupational exposures of relevance to the respiratory system and their subsequent adverse effects within the service industries and occupations, as outlined by the U.S. Department of Labor Bureau of Labor Statistics Occupational Outlook Handbook, 2007. ^ Design. Systematic review of the literature from an Ovid search including years 1950 to 2008. Initially, occupational respiratory disease categories were searched, and then combined with each of the different occupations for a comprehensive review of the literature. ^ Results. Ten groups within the U.S. Department of Labor Bureau of Labor Statistics Occupational Outlook Handbook, 2007 were identified as having exposures leading to occupational respiratory disease. These include janitors/cleaners, dental personnel, cosmetology professionals, traffic police, veterinary personnel, firefighters, healthcare workers, bakers, and bar/restaurant workers. The most common respiratory disorder affecting this population was occupational asthma caused by many different exposures in each occupation. The biggest limitation was the absence of a uniform reporting method for occupational respiratory diseases. ^ Conclusion. There is evidence that there are risks for occupational respiratory disease in the services industry. ^ Key Words: occupational and respiratory disease and service industries ^
Resumo:
Objective. To describe the spectrum and occurrence of occupational exposures of relevance to the respiratory system and their subsequent adverse effects within the service industries and occupations, as outlined by the U.S. Department of Labor Bureau of Labor Statistics Occupational Outlook Handbook, 2007. ^ Design. Systematic review of the literature from an Ovid search including years 1950 to 2008. Initially, occupational respiratory disease categories were searched, and then combined with each of the different occupations for a comprehensive review of the literature. ^ Results. Ten groups within the U.S. Department of Labor Bureau of Labor Statistics Occupational Outlook Handbook, 2007 were identified as having exposures leading to occupational respiratory disease. These include janitors/cleaners, dental personnel, cosmetology professionals, traffic police, veterinary personnel, firefighters, healthcare workers, bakers, and bar/restaurant workers. The most common respiratory disorder affecting this population was occupational asthma caused by many different exposures in each occupation. The biggest limitation was the absence of a uniform reporting method for occupational respiratory diseases. ^ Conclusion. There is evidence that there are risks for occupational respiratory disease in the services industry. ^ Key Words. occupational and respiratory disease and service industries ^
Devices in heart failure: potential methods for device-based monitoring of congestive heart failure.
Resumo:
Congestive heart failure has long been one of the most serious medical conditions in the United States; in fact, in the United States alone, heart failure accounts for 6.5 million days of hospitalization each year. One important goal of heart-failure therapy is to inhibit the progression of congestive heart failure through pharmacologic and device-based therapies. Therefore, there have been efforts to develop device-based therapies aimed at improving cardiac reserve and optimizing pump function to meet metabolic requirements. The course of congestive heart failure is often worsened by other conditions, including new-onset arrhythmias, ischemia and infarction, valvulopathy, decompensation, end-organ damage, and therapeutic refractoriness, that have an impact on outcomes. The onset of such conditions is sometimes heralded by subtle pathophysiologic changes, and the timely identification of these changes may promote the use of preventive measures. Consequently, device-based methods could in the future have an important role in the timely identification of the subtle pathophysiologic changes associated with congestive heart failure.
Resumo:
A number of indoor environmental factors, including bioaerosol or aeroallergen concentrations have been identified as exacerbators for asthma and allergenic conditions of the respiratory system. People generally spend 90% to 95% of their time indoors. Therefore, understanding the environmental factors that affect the presence of aeroallergens indoors as well as outdoors is important in determining their health impact, and in identifying potential intervention methods. This study aimed to assess the relationship between indoor airborne fungal spore concentrations and indoor surface mold levels, indoor versus outdoor airborne fungal spore concentrations and the effect of previous as well as current water intrusion. Also, the association between airborne concentration of indoor fungal spores and surface mold levels and the age of the housing structure were examined. Further, the correlation between indoor concentrations of certain species was determined as well. ^ Air and surface fungal measurements and related information were obtained from a Houston-area data set compiled from visits to homes filing insurance claims. During the sampling visit these complaint homes exhibited either visible mold or a combination of visible mold and water intrusion problems. These data were examined to assess the relationships between the independent and dependent variables using simple linear regression analysis, and independent t-tests. To examine the correlation between indoor concentrations of certain species, Spearman correlation coefficients were used. ^ There were 126 houses sampled, with spring, n=43 (34.1%), and winter, n=42 (33.3%), representing the seasons with the most samples. The summer sample illustrated the highest geometric mean concentration of fungal spores, GM=5,816.5 relative to winter, fall and spring (GM=1,743.4, GM=3,683.5 and GM=2,507.4, respectively). In all seasons, greater concentrations of fungal spores were observed during the cloudy weather conditions. ^ The results indicated no statistically significant association between outdoor total airborne fungal spore concentration and total living room airborne fungal spore concentration (β = 0.095, p = 0.491). Second, living room surface mold levels were not associated with living room airborne fungal spore concentration, (β= 0.011, p = 0.669). Third, houses with and without previous water intrusion did not differ significantly with respect to either living room (t(111) = 0.710, p = 0.528) or bedroom (t(111) =1.673, p = 0.162) airborne fungal spore concentrations. Likewise houses with and without current water intrusion did not differ significantly with respect to living room (t(109)=0.716, p = 0.476) or bedroom (t(109) = 1.035, p = 0.304) airborne fungal spore concentration. Fourth, houses with and without current water intrusion did not differ significantly with respect to living room (χ 2 (5) = 5.61, p = 0.346), or bedroom (χ 2 (5) = 1.80, p = 0.875) surface mold levels. Fifth, the age of the house structure did not predict living room (β = 0.023, p = 0.102) and bedroom (β = 0.023, p = 0.065) surface mold levels nor living room (β = 0.002, p = 0.131) and bedroom (β = 0.001, p = 0.650) fungal spore airborne concentration. Sixth, in houses with visually observed mold growth there was statistically significant differences between the mean living room concentrations and mean outdoor concentrations for Cladosporium (t (107) = 11.73, p < 0.0001), Stachybotrys (t (106)=2.288, p = 0.024, and Nigrosporia (t (102) = 2.267, p = 0.025). Finally, there was a significant correlation between several living room fungal species pairs, namely, Cladosporium and Stachybotrys (r = 0.373, p <0.01, n=65), Curvularia and Aspergillus/Penicillium (r = 0.205, p < 0.05, n= 111)), Curvularia and Stachybotrys (r = 0.205, p < 0.05, n=111), Nigrospora and Chaetomium (r = 0.254, p < 0.01, n=105) and Stachybotrys and Nigrospora (r = 0.269, p < 0.01, n=105). ^ This study has demonstrated several positive findings, i.e., significant pairwise correlations of concentrations of several fungal species in living room air, and significant differences between indoor and outdoor concentrations of three fungal species in homes with visible mold. No association was observed between indoor and outdoor fungal spore concentrations. Neither living room nor bedroom airborne spore concentrations and surface mold levels were related to the age of the house or to water intrusion, either previous or current. Therefore, these findings suggest the need for evaluating additional parameters, as well as combinations of factors such as humidity, temperature, age of structure, ventilation, and room size to better understand the determinants of airborne fungal spore concentrations and surface mold levels in homes. ^
Resumo:
I have developed a novel approach to test for toxic organic substances adsorbed onto ultra fine particulate particles present in the ambient air in Northeast Houston, Texas. These particles are predominantly carbon soot with an aerodynamic diameter (AD) of <2.5 μm. If present in the ambient air, many of the organic substances will be absorbed to the surface of the particles (which act just like a charcoal air filter), and may be adducted into the respiratory system. Once imbedded into the lungs these particles may release the adsorbed toxic organic substances with serious health consequences. I used a Airmetrics portable Minivol air sampler time drawing the ambient air through collection filters samples from 6 separate sites in Northeast Houston, an area known for high ambient PM 2.5 released from chemical plants and other sources (e.g. vehicle emissions).(1) In practice, the mass of the collected particles were much less than the mass of the filters. My technique was designed to release the adsorbed organic substances on the fine carbon particles by heating the filter samples that included the PM 2.5 particles prior to identification by gas chromatography/mass spectrometry (GCMS). The results showed negligible amounts of target chemicals from the collection filters. However, the filters alone released organic substances and GCMS could not distinguish between the organic substances released from the soot particles from those released from the heated filter fabric. However, an efficacy tests of my method using two wax burning candles that released soot revealed high levels of benzene. This suggests that my method has the potential to reveal the organic substances adsorbed onto the PM 2.5 for analysis. In order to achieve this goal, I must refine the particle collection process which would be independent of the filters; the filters upon heating also release organic substances obscuring the contribution from the soot particles. To obtain pure soot particles I will have to filter more air so that the soot particles can be shaken off the filters and then analyzed by my new technique. ^
Resumo:
Anthrax outbreaks in the United States and Europe and its potential use as a bioweapon have made Bacillus anthracis an interest of study. Anthrax infections are caused by the entry of B. anthracis spores into the host via the respiratory system, the gastrointestinal tract, cuts or wounds in the skin, and injection. Among these four forms, inhalational anthrax has the highest lethality rate and persistence of spores in the lungs of animals following pulmonary exposure has been noted for decades. However, details or mechanisms of spore persistence were not known. In this study, we investigated spore persistence in a mouse model. The results suggest that B. anthracis spores have special properties that promote persistence in the lung, and that there may be multiple mechanisms contributing to spore persistence. Moreover, recent discoveries from our laboratory suggest that spores evolved a sophisticated mechanism to interact with the host complement system. The complement system is a crucial part of the host defense mechanism against foreign microorganisms. Knowledge of the specific interactions that occur between the complement system and B. anthracis was limited. Studies performed in our laboratory have suggested that spores of B. anthracis can target specific proteins, such as Factor H (fH) of the complement system. Spores of B. anthracis are enclosed by an exosporium, which consists of a basal layer surrounded by a nap of hair-like filaments. The major structural component of the filaments is called Bacillus collagen-like protein of anthracis (BclA), which comprises a central collagen-like region and a globular C-terminal domain. BclA is the first point of contact with the innate system of an infected host. In this study, we investigated the molecular details of BclA-fH interaction with respect to the specific binding mechanism and the functional significance of this interaction in a murine model of anthrax infection. We hypothesized that the recruitment of fH to the spore surface by BclA limits the extent of complement activation and promotes pathogen survival and persistence in the infected host. Findings from this study are significant to understanding how to treat post-exposure prophylaxis and improve our knowledge of spores with the host immune system.
Resumo:
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a noninvasive technique for quantitative assessment of the integrity of blood-brain barrier and blood-spinal cord barrier (BSCB) in the presence of central nervous system pathologies. However, the results of DCE-MRI show substantial variability. The high variability can be caused by a number of factors including inaccurate T1 estimation, insufficient temporal resolution and poor contrast-to-noise ratio. My thesis work is to develop improved methods to reduce the variability of DCE-MRI results. To obtain fast and accurate T1 map, the Look-Locker acquisition technique was implemented with a novel and truly centric k-space segmentation scheme. In addition, an original multi-step curve fitting procedure was developed to increase the accuracy of T1 estimation. A view sharing acquisition method was implemented to increase temporal resolution, and a novel normalization method was introduced to reduce image artifacts. Finally, a new clustering algorithm was developed to reduce apparent noise in the DCE-MRI data. The performance of these proposed methods was verified by simulations and phantom studies. As part of this work, the proposed techniques were applied to an in vivo DCE-MRI study of experimental spinal cord injury (SCI). These methods have shown robust results and allow quantitative assessment of regions with very low vascular permeability. In conclusion, applications of the improved DCE-MRI acquisition and analysis methods developed in this thesis work can improve the accuracy of the DCE-MRI results.