8 resultados para Data monitoring committees

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Utilizing advanced information technology, Intensive Care Unit (ICU) remote monitoring allows highly trained specialists to oversee a large number of patients at multiple sites on a continuous basis. In the current research, we conducted a time-motion study of registered nurses’ work in an ICU remote monitoring facility. Data were collected on seven nurses through 40 hours of observation. The results showed that nurses’ essential tasks were centered on three themes: monitoring patients, maintaining patients’ health records, and managing technology use. In monitoring patients, nurses spent 52% of the time assimilating information embedded in a clinical information system and 15% on monitoring live vitals. System-generated alerts frequently interrupted nurses in their task performance and redirected them to manage suddenly appearing events. These findings provide insight into nurses’ workflow in a new, technology-driven critical care setting and have important implications for system design, work engineering, and personnel selection and training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most statistical analysis, theory and practice, is concerned with static models; models with a proposed set of parameters whose values are fixed across observational units. Static models implicitly assume that the quantified relationships remain the same across the design space of the data. While this is reasonable under many circumstances this can be a dangerous assumption when dealing with sequentially ordered data. The mere passage of time always brings fresh considerations and the interrelationships among parameters, or subsets of parameters, may need to be continually revised. ^ When data are gathered sequentially dynamic interim monitoring may be useful as new subject-specific parameters are introduced with each new observational unit. Sequential imputation via dynamic hierarchical models is an efficient strategy for handling missing data and analyzing longitudinal studies. Dynamic conditional independence models offers a flexible framework that exploits the Bayesian updating scheme for capturing the evolution of both the population and individual effects over time. While static models often describe aggregate information well they often do not reflect conflicts in the information at the individual level. Dynamic models prove advantageous over static models in capturing both individual and aggregate trends. Computations for such models can be carried out via the Gibbs sampler. An application using a small sample repeated measures normally distributed growth curve data is presented. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To examine associations between parental monitoring and adolescent alcohol/drug use. ^ Methods. 981 7th grade students from 10 inner-city middle schools were surveyed at the 3 month follow-up of an HIV, STD, and pregnancy prevention program. Data from 549 control subjects were used for analyses. Multinomial logistic regression was used to examine associations between five parental monitoring variables and substance use, coded as: low risk [never drank alcohol or used drugs (0)], moderate risk [drank alcohol, no drug use (1)], and high risk [both drank alcohol and used drugs or just used drugs (2)]. ^ Results. Participants were 58.3% female, 39.6% African American, 43.8% Hispanic, mean age 13.3 years. Lifetime alcohol use was 47.9%. Lifetime drug use was 14.9%. Adjusted for gender, age, race, and family structure, each individual parental monitoring variable (perceived parental monitoring, less permissive parental monitoring, greater supervision (public places), greater supervision (teen clubs), and less time spent with older teens) was significant and protective for the moderate and high risk groups. When all 5 variables were entered into a single model, only perceived parental monitoring was significantly associated (OR=0.40, 95% CI 0.29-0.55) for the moderate risk group. For the high risk group, 3 variables were significantly protective (perceived parental monitoring OR=0.28, CI 0.18-0.42, less time spent with older teens OR=0.75, CI 0.60-0.93, and greater supervision (public places) OR=0.79, CI 0.64-0.99). ^ Conclusion. The association between parental monitoring and substance abuse is complex and varied for different risk levels. Implications for intervention development are addressed. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potential for the direct analysis of enzyme reactions by fast atom bombardment (FAB) mass spectrometry has been investigated. Conditions are presented for the maintenance of enzymatic activity under FAB conditions along with FAB mass spectrometric data showing that these conditions can be applied to solutions of enzyme and substrate to follow enzymatic reactions inside the mass spectrometer in real-time. In addition, enzyme kinetic behavior under FAB mass spectrometric conditions is characterized using trypsin and its assay substrate, TAME, as an enzyme-substrate reaction model. These results show that two monitoring methods can be utilized to follow reactions by FAB mass spectrometry. The advantages of each method are discussed and illustrated by obtaining kinetic parameters from the direct analysis of enzyme reactions with assay or peptide substrates. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Despite the ban of lead-containing gasoline and paint, childhood lead poisoning remains a public health issue. Furthermore, a Medicaid-eligible child is 8 times more likely to have an elevated blood lead level (EBLL) than a non-Medicaid child, which is the primary reason for the early detection lead screening mandate for ages 12 and 24 months among the Medicaid population. Based on field observations, there was evidence that suggested a screening compliance issue. Objective. The purpose of this study was to analyze blood lead screening compliance in previously lead poisoned Medicaid children and test for an association between timely lead screening and timely childhood immunizations. The mean months between follow-up tests were also examined for a significant difference between the non-compliant and compliant lead screened children. Methods. Access to the surveillance data of all childhood lead poisoned cases in Bexar County was granted by the San Antonio Metropolitan Health District. A database was constructed and analyzed using descriptive statistics, logistic regression methods and non-parametric tests. Lead screening at 12 months of age was analyzed separately from lead screening at 24 months. The small portion of the population who were also related were included in one analysis and removed from a second analysis to check for significance. Gender, ethnicity, age of home, and having a sibling with an EBLL were ruled out as confounders for the association tests but ethnicity and age of home were adjusted in the nonparametric tests. Results. There was a strong significant association between lead screening compliance at 12 months and childhood immunization compliance, with or without including related children (p<0.00). However, there was no significant association between the two variables at the age of 24 months. Furthermore, there was no significant difference between the median of the mean months of follow-up blood tests among the non-compliant and compliant lead screened population for at the 12 month screening group but there was a significant difference at the 24 month screening group (p<0.01). Discussion. Descriptive statistics showed that 61% and 56% of the previously lead poisoned Medicaid population did not receive their 12 and 24 month mandated lead screening on time, respectively. This suggests that their elevated blood lead level may have been diagnosed earlier in their childhood. Furthermore, a child who is compliant with their lead screening at 12 months of age is 2.36 times more likely to also receive their childhood immunizations on time compared to a child who was not compliant with their 12 month screening. Even though there was no statistical significant association found for the 24 month group, the public health significance of a screening compliance issue is no less important. The Texas Medicaid program needs to enforce lead screening compliance because it is evident that there has been no monitoring system in place. Further recommendations include a need for an increased focus on parental education and the importance of taking their children for wellness exams on time.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous research has shown dietary intake self-monitoring, and culturally tailored weight loss interventions to be effective tools for weight loss. Technology can be used to tailor weight loss interventions to better suit adolescents. There is a lack of research to date on the use of personal digital assistants (PDAs) to self-monitor dietary intake among adolescents. The objective of this study was to determine the difference in dietary intake self-monitoring frequency between using a Personal Digital Assistant (PDA) or paper logs as a diet diary in obese adolescent females; and to describe differences in diet adherence, as well as changes in body size and self-efficacy to resist eating. We hypothesized dietary intake self-monitoring frequency would be greater during PDA use than during paper log use. This study was a randomized crossover trial. Participants recorded their diet for 4 weeks: 2 weeks on a PDA and 2 weeks on paper logs. Thirty-four obese females ages 12-20 were recruited for participation. Thirty were included in analyses. Participants recorded more entries/day while using the paper logs (4.10 entries/day ± 0.63) than while using the PDA (3.01 entries/day ±0.75) (p<0.001). Significantly more meals and snacks were skipped during paper log use (0.81/day ± 0.65) than during PDA use (0.23/day ± 0.22) (p=0.011). Changes in body size (BMI, weight, and waist circumference) and self-efficacy to resist eating did not differ significantly between PDA and paper log use. When compared to paper logs, participants felt the PDA was more convenient (p=0.020), looked forward to using the PDA more (p=0.008), and would rather continue using the PDA than the paper logs (p=0.020). The findings of this study indicate use of a PDA as a dietary intake self-monitoring tool among adolescents would not result in increased dietary intake self-monitoring to aid in weight loss. Use of paper logs would result in greater data returned to clinicians, though use of PDAs would likely get adolescents more excited about adhering to recommendations to record their diet. Future research should look at updated communication devices, such as cell phones and other PDAs with additional features, and the role they can play in increasing dietary intake self-monitoring among adolescents.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using $\alpha$/$\beta$ discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen.^ U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-$\ell$ aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi $\ell\sp{-1}$. $\alpha$-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi $\ell\sp-1$ are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain $\sp{234}$U/$\sp{238}$U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation.^ The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross $\alpha$ activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi $\ell\sp{-1}$, with seven samples exceeding the proposed Maximum Contaminant Level of 20 $\mu$g $\ell\sp{-1}$. Four exceeded the proposed activity screening level of 30 pCi $\ell\sp{-1}$. Isotopic ratios ranged from 0.87 to 41.8, while one sample contained $\sp{234}$U activity of 34.6 pCi $\ell\sp{-1}$ in the complete absence of its parent, $\sp{238}$U. U mass in the samples with elevated activity ranged from 0.0 to 103 $\mu$g $\ell\sp{-1}$. A limited test of screening surface and groundwaters for contamination by U from waste sites and natural processes was also successful. ^