4 resultados para Criterion-related validity

em DigitalCommons@The Texas Medical Center


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: : Women at increased risk of breast cancer (BC) are not widely accepting of chemopreventive interventions, and ethnic minorities are underrepresented in related trials. Furthermore, there is no validated instrument to assess the health-seeking behavior of these women with respect to these interventions. METHODS: : By using constructs from the Health Belief Model, the authors developed and refined, based on pilot data, the Breast Cancer Risk Reduction Health Belief (BCRRHB) scale using a population of 265 women at increased risk of BC who were largely medically underserved, of low socioeconomic status (SES), and ethnic minorities. Construct validity was assessed using principal components analysis with oblique rotation to extract factors, and generate and interpret summary scales. Internal consistency was determined using Cronbach alpha coefficients. RESULTS: : Test-retest reliability for the pilot and final data was calculated to be r = 0.85. Principal components analysis yielded 16 components that explained 64% of the total variance, with communalities ranging from 0.50-0.75. Cronbach alpha coefficients for the extracted factors ranged from 0.45-0.77. CONCLUSIONS: : Evidence suggests that the BCRRHB yields reliable and valid data that allows for the identification of barriers and enhancing factors associated with use of breast cancer chemoprevention in the study population. These findings allow for tailoring treatment plans and intervention strategies to the individual. Future research is needed to validate the scale for use in other female populations. Cancer 2009. (c) 2009 American Cancer Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last thirty years, increasing efforts have been made to reduce the prevalence of adolescent tobacco use in the United States. Although the prevalence has declined dramatically over the past decade, there are still sharp differences in adolescent smoking-initiation rates across racial/ethnic groups. Large-scale surveys frequently assess smoking-related attitudes, self-efficacy, and intentions to explain the differences in smoking rates between African Americans and Whites. However, there is little agreement about which constructs are significant. Moreover, the psychometric properties of smoking-related attitude, self-efficacy, and intention constructs have not been fully examined. More studies are needed to understand existing patterns of tobacco use and to validate and fully exploit the constructs' relationship to adolescent smoking initiation across racial/ethnic groups. ^ This dissertation reports on a secondary analysis of data from a large multi-ethnic convenience sample of sixth- through eighth-grade students in 22 schools in East Texas and the city of Houston. The specific aims of this dissertation were to (1) describe smoking and alternate tobacco product use rates by race/ethnicity, gender, age, and grade level (Article 1); (2) test the factorial validity of smoking-related attitudes, self-efficacy, and intentions using confirmatory factor analysis techniques (Article 2); and (3) test the factorial invariance of smoking-related attitudes, self-efficacy, and intentions between African Americans and Whites (Article 3). ^ The prevalence findings confirm the disparities in tobacco use among African American, Hispanic, and White adolescents that other surveys have reported (Article 1). This study also demonstrates the usefulness of examining use patterns of not only cigarettes but also alternative tobacco products in younger multiethnic populations, as well as of providing epidemiological data estimates about different phases of smoking. The confirmatory factor analysis provides evidence of construct validity of attitude, self-efficacy, and intention scales for the multiethnic sample (Article 2). Finally, the factorial invariance analyses indicates that some measures representing smoking-related attitudes, self-efficacy, and intentions may not be appropriate for use among both African Americans and Whites (Article 3). Additional research is needed to further our understanding of the patterns and predictors of youth tobacco use initiation. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are several tools for measuring quality of life (QoL) and specifically, health-related quality of life (HRQoL) for persons with diabetes. A commonly-used measure, the Diabetes Quality of Life (DQOL) Survey, developed for the Diabetes Control and Complications Trial (DCCT), has been used in several experimental settings, and its reliability and validity are well-established. However, it is considered too long to be of practical use in clinical settings. Because of this, a shortened version of the tool was used recently in the Community Diabetes Education (CoDE) Project in Dallas, Texas, a clinic-based patient education program that uses a specially-trained community healthcare worker to provide patient education. However, the modified scale has never been tested for reliability and validity. Thus, one goal of this thesis was to measure these psychometric properties of the scale. After establishing the reliability and validity, the results of the scale were analyzed to determine the effects of the intervention on the subjects’ quality of life. The changes in QoL scales were compared with changes in physiologic measures which are most closely allied with diabetes, including blood glucose levels, weight/BMI, co-morbidities and health beliefs in order to determine if there is a relationship between such measures and quality of life. The results of the reliability and validity testing were not conclusive. Measures of reliability and criterion validity were established, but these contrasted with poor measures of repeatability and content validity. The effect of the intervention on quality of life, however, was more significant, particularly regarding the impact of diabetes. Those who received the counseling had significantly higher scores on the Impact scale than those who did not, and the former group had much greater improvement in scores over the twelve month period than the latter group. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Surgeon General recommends preschoolers 3-5 years old accumulate 60 minutes of moderate-to-vigorous physical activity (MVPA) per day. However, there is limited data measuring physical activity (PA) and MVPA amongst this population. The purpose of this cross-sectional study is to determine the validity, reliability, and feasibility of using MVP 4 Function Walk4Life digital pedometers (MVP-4) in measuring MVPA among preschoolers using the newly modified direct observational technique, System for Observing Fitness Instruction Time-Preschool Version (SOFIT-P) as the gold standard. An ethnically diverse population of 3-5 year old underserved children were recruited from two Harris County Department of Education (HCDE) Head Start centers. For 2 days at baseline and 2 days at post-test, 75 children enrolled wore MVP-4 pedometers for approximately 6-hours per observation day and were observed using SOFIT-P during predominantly active times. Statistical analyses used Pearson "r" correlation coefficients to determine mean minutes of PA and MVPA, convergent and criterion validity, and reliability. Significance was set at p = <0.05. Feasibility was determined through process evaluation information collected during this study via observations from data collectors and teacher input. Results show mean minutes of PA and MVPA ranged between 30-42 and 11-14 minutes, respectively. Convergent validity comparing BMI percentiles with MVP-4 PA outcomes show no significance at pre-test; however, each measurement at post-test showed significance for MVPA (p = 0.0247, p = 0.0056), respectively. Criterion validity comparing percent MVPA time between SOFIT-P and MVP-4 pedometers was determined; however, results deemed insufficient due to inconsistency in observation times while using the newly developed SOFIT-P. Reliability measures show no significance at pre-test, yet show significant results for all PA outcomes at post-test (p = 0.001, p = 0.001, p = 0.0010, p = 0.003), respectively. Finally, MVP-4 pedometers lacked feasibility due to logistical barriers in design. Researchers feel the significant results at post-test are secondary to increased familiarity and more accurate placement of pedometers across time. Researchers suggest manufacturers of MVP-4 pedometers further modify the instrument for ease of use with this population, following which future studies ought to determine validity using objective measures or all-day direct observation techniques.^