4 resultados para Continuous performance measurement

em DigitalCommons@The Texas Medical Center


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the context of a healthcare organization, such as a hospital that provides medical care to its community, performance cannot be measured without special attention to quality. Indeed, quality is as important as finance not only in measuring performance for the organization, but also in securing the organization's viability and competitiveness in the long run.^ Yet quality today is not adequately understood and managed. An inductive framework for integrating finance and quality for purposes of organizational performance measurement as well as strategic planning is proposed in this dissertation. Future areas of research are discussed.^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Serotonin (5-HT) neurotransmission deficits have been implicated in impulsive aggression. A Trp-free beverage of amino acids competitively inhibits Trp uptake into the brain for 5-HT synthesis and also lowers endogenous plasma Trp for several hours. This has worsened mood and/or increased aggressive behavior, especially in hostile persons or those with histories of depression. In 24 community-recruited men (12 each with and without significant aggression histories), aggressive and impulsive behavior in the laboratory was assessed before and after plasma Trp depletion and Trp loading. In the aggression model, subjects were provoked by periodic subtractions of participation earnings, and these subtractions were blamed on a ficitious other participant. Aggression was measured as the responses the subject made to subtract money from his antagonist. Impulsiveness was operationalized as: (1) the choice of smaller reward after a shorter delay over having to wait longer to receive a larger reward, and (2) “false alarm” commission errors in a modified Continuous Performance Task, which represent a failure to inhibit responding to stimuli similar (but not identical) to target stimuli. Finally, plasma cortisol and Trp were measured under each condition immediately following a aggression testing session when subjects were highly provoked. I hypothesized that 5-HT may tonically modulate (inhibit) the hypothalmnic-pituitary-adrenal stress response, such that Trp depletion may enhance the cortisol response to high provocation in aggressive men. ^ Trp depletion had no effect in the laboratory tasks purported to measure impulsive behavior, and failed to cause increases in aggressive behavior under low provocation conditions. Under higher provocation, however, aggressive responses we re elevated under Trp-depleted conditions relative to Trp-loaded conditions in aggressive men, whereas the reverse was true in nonaggressive men. Cortisol levels nonsignificantly paralled the group differences in aggression under Trp-depleted and Trp-loaded conditions. Aggressive men achieved lower plasma Trp levels after Trp loading than did nonaggressive men, possibly due to heavy alcohol use histories. The high post-loading plasma Trp levels in nonaggressive men tended also to correlate with their aggressive responding rates, due perhaps to increases in other psychoactive Trp metabolites. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The Texas Occupational Safety & Health Surveillance System (TOSHSS) was created to collect, analyze and interpret occupational injury and illness data in order to decrease the impact of occupational injuries within the state of Texas. This process evaluation was performed midway through the 4-year grant to assess the efficiency and effectiveness of the surveillance system’s planning and implementation activities1. ^ Methods: Two evaluation guidelines published by the Centers for Disease Control and Prevention (CDC) were used as the theoretical models for this process evaluation. The Framework for Program Evaluation in Public Health was used to examine the planning and design of TOSHSS using logic models. The Framework for Evaluating Public Health Surveillance Systems was used to examine the implementation of approximately 60 surveillance activities, including uses of the data obtained from the surveillance system. ^ Results/Discussion: TOSHSS planning activities omitted the creation of a scientific advisory committee and specific activities designed to maintain contacts with stakeholders; and proposed activities should be reassessed and aligned with ongoing performance measurement criteria, including the role of collaborators in helping the surveillance system achieve each proposed activity. TOSHSS implementation activities are substantially meeting expectations and received an overall score of 61% for all activities being performed. TOSHSS is considered a surveillance system that is simple, flexible, acceptable, fairly stable, timely, moderately useful, with good data quality and a PVP of 86%. ^ Conclusions: Through the third year of TOSHSS implementation, the surveillance system is has made a considerable contribution to the collection of occupational injury and illness information within the state of Texas. Implementation of the nine recommendations provided under this process evaluation is expected to increase the overall usefulness of the surveillance system and assist TDSHS in reducing occupational fatalities, injuries, and diseases within the state of Texas. ^ 1 Disclaimer: The Texas Occupational Safety and Health Surveillance System is supported by Grant/Cooperative Agreement Number (U60 OH008473-01A1). The content of the current evaluation are solely the responsibility of the authors and do not necessarily represent the official views of the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose. The aim of this research was to evaluate the effect of enteral feeding on tonometric measurement of gastric regional carbon dioxide levels (PrCO2) in normal healthy volunteers. Design and methods. The sample included 12 healthy volunteers recruited by the University Clinical Research Center (UCRC). An air tonometry system monitored PrCO2 levels using a tonometer placed in the lumen of the stomach via orogastric intubation. PrCO2 was automatically measured and recorded every 10 minutes throughout the five hour study period. An oral dose of famotidine 40 mg was self-administered the evening prior to and the morning of the study. Instillation of Isocal® High Nitrogen (HN) was used for enteral feeding in hourly escalating doses of 0, 40, 60, and 80 ml/hr with no feeding during the fifth hour. Results . PrCO2 measurements at time 0 and 10 minutes (41.4 ± 6.5 and 41.8 ± 5.7, respectively) demonstrated biologic precision (Levene's Test statistic = 0.085, p-value 0.774). Biologic precision was lost between T130 and T140 40 when compared to baseline TO (Levene's Test statistic = 1.70, p-value 0.205; and 3.205, p-value 0.042, respectively) and returned to non-significant levels between T270 and T280 (Levene's Test statistic = 3.083, p-value 0.043; and 2.307, p-value 0.143, respectively). Isocal® HN significantly affected the biologic accuracy of PrCO2 measurements (repeated measures ANOVA F 4.91, p-value <0.001). After 20 minutes of enteral feeding at 40 ml/hr, PrCO2 significantly increased (41.4 ± 6.5 to 46.6 ± 4.25, F = 5.4, p-value 0.029). Maximum variance from baseline (41.4 ± 6.5 to 61.3 ± 15.2, F = 17.22, p-value <0.001) was noted after 30 minutes of Isocal® HN at 80 ml/hr or 210 minutes from baseline. The significant elevations in PrCO2 continued throughout the study. Sixty minutes after discontinuation of enteral feeding, PrCO2 remained significantly elevated from baseline (41.4 ± 6.5 to 51.8 ± 9.2, F = 10.15, p-value 0.004). Conclusion. Enteral feeding with Isocal® HN significantly affects the precision and accuracy of PrCO2 measurements in healthy volunteers. ^