3 resultados para Condition monitoring systems

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the multiple case-study was to determine how hospital subsystems (such as physician monitoring and credentialing; quality assurance; risk management; and peer review) were supporting the monitoring of physicians? Three large metropolitan hospitals in Texas were studied and designated as hospitals #1, #2, and #3. Realizing that hospital subsystems are a unique entity and part of a larger system, conclusions were made on the premises of a quality control system, in relation to the tools of government (particularly the Health Care Quality Improvement Act (HCQIA)), and in relation to itself as a tool of a hospital.^ Three major analytical assessments were performed. First, the subsystems were analyzed as to their "completeness"; secondly, the subsystems were analyzed for "performance"; and thirdly, the subsystems were analyzed in reference to the interaction of completeness and performance.^ The physician credentialing and monitoring and the peer review subsystems as quality control systems were most complete, efficient, and effective in hospitals #1 and #3. The HCQIA did not seem to be an influencing factor in the completeness of the subsystem in hospital #1. The quality assurance and risk management subsystem in hospital #2 was not representative of completeness and performance and the HCQIA was not an influencing factor in the completeness of the Q.A. or R.M. systems in any hospital. The efficiency (computerization) of the physician credentialing, quality assurance and peer review subsystems in hospitals #1 and #3 seemed to contribute to their effectiveness (system-wide effect).^ The results indicated that the more complete, effective, and efficient subsystems were characterized by (1) all defined activities being met, (2) the HCQIA being an influencing factor, (3) a decentralized administrative structure, (4) computerization an important element, and (5) staff was sophisticated in subsystem operations. However, other variables were identified which deserve further research as to their effect on completeness and performance of subsystems. They include (1) medical staff affiliations, (2) system funding levels, (3) the system's administrative structure, and (4) the physician staff "cultural" characteristics. Perhaps by understanding other influencing factors, health care administrators may plan subsystems that will be compatible with legislative requirements and administrative objectives. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any robust quality control program is the determination of significant deviations from standard or baseline conditions, clinicians and vendors often neglect the temporal nature of detector degradation (1). This thesis describes the development and testing of new methods for monitoring detector uniformity. These techniques provide more quantitative, sensitive, and specific feedback to the reviewer so that he or she may be better equipped to identify performance degradation prior to its manifestation in clinical images. The methods exploit the temporal nature of detector degradation and spatially segment distinct regions-of-non-uniformity using multi-resolution decomposition. These techniques were tested on synthetic phantom data using different degradation functions, as well as on experimentally acquired time series floods with induced, progressively worsening defects present within the field-of-view. The sensitivity of conventional, global figures-of-merit for detecting changes in uniformity was evaluated and compared to these new image-space techniques. The image-space algorithms provide a reproducible means of detecting regions-of-non-uniformity prior to any single flood image’s having a NEMA uniformity value in excess of 5%. The sensitivity of these image-space algorithms was found to depend on the size and magnitude of the non-uniformities, as well as on the nature of the cause of the non-uniform region. A trend analysis of the conventional figures-of-merit demonstrated their sensitivity to shifts in detector uniformity. The image-space algorithms are computationally efficient. Therefore, the image-space algorithms should be used concomitantly with the trending of the global figures-of-merit in order to provide the reviewer with a richer assessment of gamma camera detector uniformity characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the study was to describe regionalized systems of perinatal care serving predominantly low income Mexican-American women in rural underserved areas of Texas. The study focused upon ambulatory care; however, it provided a vehicle for examination of the health care system. The questions posed at the onset of the study included: (1) How well do regional organizations with various patterns of staffing and funding levels perform basic functions essential to ambulatory perinatal care? (2) Is there a relationship between the type of organization, its performance, and pregnancy outcome? (3) Are there specific recommendations which might improve an organization's future performance?^ A number of factors--including maldistribution of resources and providers, economic barriers, inadequate means of transportation, and physician resistance to transfer of patients between levels of care--have impeded the development of regionalized systems of perinatal health care, particularly in rural areas. However, studies have consistently emphasized the role of prenatal care in the early detection of risk and treatment of complications of pregnancy and childbirth, with subsequent improvement in pregnancy outcomes.^ This study has examined the "system" of perinatal care in rural areas, utilizing three basic regional models--preventive care, limited primary care, and fully primary care. Information documented in patient clinical records was utilized to compare the quality of ambulatory care provided in the three regional models.^ The study population included 390 women who received prenatal care in one of the seven study clinics. They were predominantly hispanic, married, of low income, with a high proportion of teenagers and women over 35. Twenty-eight percent of the women qualified as migrants.^ The major findings of the study are listed below: (1) Almost half of the women initiated care in the first trimester. (2) Three-fourths of the women had or exceeded the recommended number of prenatal visits. (3) There was a low rate of clinical problem recognition. Additional follow-up is needed to determine the reasons. (4) Cases with a tracer condition had significantly more visits with monitoring of the clinical condition. (5) Almost 90% of all referrals were completed. (6) Only 60% of mothers had postpartum follow-up, while almost 90% of their newborns received care. (7) The incidence of infants weighing 2500 grams or less was 4.2%. ^