2 resultados para Ambient temperature

em DigitalCommons@The Texas Medical Center


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To explore the natural trajectory of core body temperature (CBT) and cortisol (CORT) circadian rhythms in mechanically ventilated intensive care unit (MV ICU) patients. ^ Design: Prospective, observational, time-series pilot study. ^ Setting: Medical-surgical and pulmonary ICUs in a tertiary care hospital. ^ Sample: Nine (F = 3, M = 6) adults who were mechanically ventilated within 12 hrs of ICU admission with mean ± SD age of 65.2 ± 14 years old. ^ Measurements: Core body temperature and environmental measures of light, sound, temperature, and relative humidity were logged in 1-min intervals. Hourly urine specimens and 2-hr interval blood specimens were collected for up to 7 consecutive days for CORT assay. Mechanical ventilation days, ICU length of stay, and ICU mortality were documented. Acute Physiology and Chronic Health Evaluation (APACHE) II scores were computed for each study day. The data of each biologic and environmental variable were analyzed using single cosinor analysis of 24-hr serial segments. One patient did not complete the study because mortality occurred within 8 hrs of enrollment. Nine ICU patients completed the study in 1.6 to 7.0 days. ^ Results: No normal circadian rhythm pattern was found when the cosinor-derived parameters of amplitude (one-half the peak-trough variability) and acrophase (peak time) were compared with cosinor-derived parameter reference ranges of healthy, diurnally active humans, although 83% of patient-day CBT segments showed statistically significant (p ≤ .05) and biologically meaningful (R2≥ 0.30) 24-hr rhythms with abnormal cosinor parameters. Cosinor parameters of the environmental temporal profiles showed 27% of light, 76% of ambient temperature, and 78% of relative humidity serial segments had a significant and meaningful 24-hr diurnal pattern. Average daily light intensity varied from 34 to 187 lx with a maximum light exposure of 1877 lx. No sound measurement segment had a statistically significant cosine pattern, and numerous 1-minute interval peaks ≥ 60 dB occurred around the clock. Average daily ambient temperature and relative humidity varied from 19 to 24°C and from 25% to 61%, respectively. There was no statistically significant association between CBT or clinical outcomes and cosinor-derived parameters of the environmental variables. Circadian rhythms of urine and plasma CORT were deferred for later analysis. ^ Conclusions: The natural trajectory of the CBT circadian rhythm in MV ICU patients demonstrated persistent cosinor parameter alteration, even when a significant and meaningful 24-hr rhythm was present. The ICU environmental measures showed erratic light and sound exposures. Room temperature and relative humidity data produced the highest rate of significant and meaningful diurnal 24-hr patterns. Additional research is needed to clarify relations among the CBT biomarker of the circadian clock and environmental variables of MV ICU patients. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Species variations in formaldehyde solutions and gases were investigated by means of infrared spectral analysis. Double beam infrared spectrometry in conjunction with sodium chloride wafer technique and solvent compensation technique were employed. Formaldehyde species in various solutions were investigated. Formalin 37% was stable for many months. Refrigeration had no effects on its stability. Spectral changes were detected in 1000 ppm formaldehyde solutions. The absorbances of very diluted solutions up to 100 ppm were lower than the detection limit of the instruments. Solvent compensation improved resolution, but was associated with an observed lack of repeatability. Formaldehyde species in animal chambers containing animals and in mobile home air were analyzed with the infrared spectrophotometer equipped with a 10 cm gas cell. Spectra were not different from the spectrum of clean air. A portable single beam infrared spectrometer with a 20 meter pathlength was used for reinvestigation. Indoor formaldehyde could not be detected in the spectral; conversely, an absorption peak at 3.58 microns was found in the spectra of 3 and 15 ppm formaldehyde gas in animal chambers. This peak did not appear in the spectrum of the control chamber. Because of concerns over measurement bias among various analytical methods for formaldehyde, side-by-side comparisons were conducted in both laboratory and field measurements. The chromotropic acid method with water and 1% sodium bisulfite as collection media, the pararosaniline method, and a single beam infrared spectrometer were compared. Measurement bias was elucidated and the extent of the effects of temperature and humidity was also determined. The problems associated with related methods were discussed. ^