8 resultados para Acceptance criteria
em DigitalCommons@The Texas Medical Center
Resumo:
Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.
Resumo:
To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.
Resumo:
BACKGROUND: Many users search the Internet for answers to health questions. Complementary and alternative medicine (CAM) is a particularly common search topic. Because many CAM therapies do not require a clinician's prescription, false or misleading CAM information may be more dangerous than information about traditional therapies. Many quality criteria have been suggested to filter out potentially harmful online health information. However, assessing the accuracy of CAM information is uniquely challenging since CAM is generally not supported by conventional literature. OBJECTIVE: The purpose of this study is to determine whether domain-independent technical quality criteria can identify potentially harmful online CAM content. METHODS: We analyzed 150 Web sites retrieved from a search for the three most popular herbs: ginseng, ginkgo and St. John's wort and their purported uses on the ten most commonly used search engines. The presence of technical quality criteria as well as potentially harmful statements (commissions) and vital information that should have been mentioned (omissions) was recorded. RESULTS: Thirty-eight sites (25%) contained statements that could lead to direct physical harm if acted upon. One hundred forty five sites (97%) had omitted information. We found no relationship between technical quality criteria and potentially harmful information. CONCLUSIONS: Current technical quality criteria do not identify potentially harmful CAM information online. Consumers should be warned to use other means of validation or to trust only known sites. Quality criteria that consider the uniqueness of CAM must be developed and validated.
Resumo:
Many clients who undergo methadone maintenance (MM) treatment for heroin and other opiate dependence prefer abstinence from methadone. Attempts at methadone detoxification are often unsuccessful, however, due to distressing physical as well as psychological symptoms. Outcomes from a MM client who voluntarily participated in an Acceptance and Commitment Therapy (ACT) - based methadone detoxification program are presented. The program consisted of a 1-month stabilization and 5-month gradual methadone dose reduction period, combined with weekly individual ACT sessions. Urine samples were collected twice weekly to assess for use of illicit drugs. The participant successfully completed the program and had favorable drug use outcomes during the course of treatment, and at the one-month and one-year follow-ups. Innovative behavior therapies, such as ACT, that focus on acceptance of the inevitable distress associated with opiate withdrawal may improve methadone detoxification outcomes.
Resumo:
This study has the purpose of determining the barriers and facilitators to nurses' acceptance of the Johnson and Johnson Protectiv®* Plus IV catheter safety needle device and implications for needlestick injuries at St. Luke's Episcopal Hospital, Houston, Texas. A one-time cross-sectional survey of 620 responding nurses was conducted by this researcher during December, 2000. The study objectives were to: (1) describe the perceived (a) organizational and individual barriers and facilitators and (b) acceptance of implementation of the IV catheter device; (2) examine the relative importance of these predictors; (3) describe (a) perceived changes in needlestick injuries after implementation of the device; (b) the reported incidence of injuries; and (c) the extent of underreporting by nurses; and (4) examine the relative importance of (a) the preceding predictors and (b) acceptance of the device in predicting perceived changes in needlestick injuries. Safety climate and training were evaluated as organizational factors. Individual factors evaluated were experience with the device, including time using it and frequency of use, and background information, including nursing unit, and length of time as a nurse in this hospital and in total nursing career. The conceptual framework was based upon the safety climate model. Descriptive statistics and multiple and logistic regression were utilized to address the study objectives. ^ The findings showed widespread acceptance of the device and a strong perception that it reduced the number of needlesticks. Acceptance was notably predicted by adequate training, appropriate time between training and device use, solid safety climate, and short length of service, in that order. A barrier to acceptance was nurses' longtime of use of previous needle technologies. Over four-fifths of nurses were compliant in always using the device. Compliance had two facilitators: length of time using device and, to a lesser extent, safety climate. Rates of compliance tended to be lower among nurses in units in which the device was frequently used. ^ High quality training and an atmosphere of caring about nurse safety stand out as primary facilitators that other institutions would need to adopt in order to achieve maximum success in implementing safety programs involving utilization of new safety devices. ^
Resumo:
Purpose. Drug users are a large group of those at highest risk for contracting Hepatitis B (HBV). This study sought to identify predictors of HBV vaccine acceptance and compliance in a cohort of current drug users in Houston, Texas. Perceived severity of HBV, perceived risk of HBV, perceived peer support of HBV vaccine, and perceived benefits of HBV vaccine were also examined assess their relationship to HBV compliance. ^ Methods. A randomized intervention study was conducted in a cohort of current drug users in Houston, Texas. Participants were recruited by community outreach workers from two urban neighborhoods in Houston known for high drug use. Participants were randomized to a standard vaccine schedule group or an accelerated vaccine schedule group. Participants were also randomized to either a standard behavioral intervention group or an enhanced behavioral intervention group designed to increase HBV vaccine acceptance and compliance. Baseline visits included an interview for demographic factors, drug and sexual behaviors, and HBV beliefs; and participants received the first dose of the HBV vaccine and one of the behavioral interventions. ^ Results. Of 1,643 screening participants, 77% accepted the HBV vaccine. Participants ages ≥50 were twice as likely to accept the vaccine. African Americans and less frequent drug users were also significantly more likely to accept the vaccine. Of the 1,259 participants who enrolled in the study, 75% were compliant to the HBV vaccine. Predictors of compliance were found to be race, housing status, and alcohol use. Speedball users were found to be 74% less likely to be compliant the HBV vaccine. None of the behavioral constructs assessed were found to significantly predict HBV compliance. However, additional analyses found that there were significant changes in mean scores of the behavioral concepts when measured at six month follow-up. ^ Conclusion. Results from this study indicate that when offered a free vaccine in the drug user community, a large percentage will be compliant to the vaccine series. The behavioral cognitions commonly used in HBV compliance research need to be extended to accurately fit this cohort. Also, vaccine intervention focus needs to be on reaching the homeless segment of the drug users and the speedball users. ^
Resumo:
Exposure to influenza places pregnant women at risk for pneumonia and their fetus at risk for premature delivery or fatal stillbirth secondary to maternal hypoxia. Immunization rates are low among pregnant women. Influenza vaccine specific-health belief model constructs, such as cue to action messages from the health care professionals, may increase acceptance of the vaccine and improve immunization rates. A systematic review was conducted to evaluate the impact of physician recommendation upon acceptance of the influenza vaccine by pregnant women. Pregnant women were more likely to accept the influenza vaccine if they received a recommendation from their physician. These women were also more likely to accept the vaccine if they thought the vaccine protected mother and fetus against adverse effects of influenza and were less likely to accept the vaccine if they were concerned about side effects or risk to the fetus from the vaccine.^
Resumo:
Background: Lynch Syndrome (LS) is a familial cancer syndrome with a high prevalence of colorectal and endometrial carcinomas among affected family members. Clinical criteria, developed from information obtained from familial colorectal cancer registries, have been generated to identify individuals at elevated risk for having LS. In 2007, the Society of Gynecologic Oncology (SGO) codified criteria to assist in identifying women presenting with gynecologic cancers at elevated risk for having LS. These criteria have not been validated in a population-based setting. Materials and Methods: We retrospectively identified 412, unselected endometrial cancer cases. Clinical and pathologic information were obtained from the electronic medical record, and all tumors were tested for expression of the DNA mismatch repair proteins through immunohistochemistry. Tumors exhibiting loss of MSH2, MSH6 and PMS2 were designated as probable Lynch Syndrome (PLS). For tumors exhibiting immunohistochemical loss of MLH1, we used the PCR-based MLH1 methylation assay to delineate PLS tumors from sporadic tumors. Samples lacking methylation of the MLH1 promoter were also designated as PLS. The sensitivity and specificity for SGO criteria for detecting PLS tumors was calculated. We compared clinical and pathologic features of sporadic tumors and PLS tumors. A simplified cost-effectiveness analysis was also performed comparing the direct costs of utilizing SGO criteria vs. universal tumor testing. Results: In our cohort, 43/408 (10.5%) of endometrial carcinomas were designated as PLS. The sensitivity and specificity of SGO criteria to identify PLS cases were 32.7 and 77%, respectively. Multivariate analysis of clinical and pathologic parameters failed to identify statistically significant differences between sporadic and PLS tumors with the exception of tumors arising from the lower uterine segment. These tumors were more likely to occur in PLS tumors. Cost-effectiveness analysis showed clinical criteria and universal testing strategies cost $6,235.27/PLS case identified and $5,970.38/PLS case identified, respectively. Conclusions: SGO 5-10% criteria successfully identify PLS cases among women who are young or have significant family history of LS related tumors. However, a larger proportion of PLS cases occurring at older ages with less significant family history are not detected by this screening strategy. Compared to SGO clinical criteria, universal tumor testing is a cost effective strategy to identify women presenting with endometrial cancer who are at elevated risk for having LS.