4 resultados para 720501 Defence standards and calibrations

em DigitalCommons@The Texas Medical Center


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To address concerns expressed about the possible effect of drilling mud discharges on shallow, low-energy estuarine ecosystems, a 12 month study was designed to detect alterations in water quality and sediment geochemistry. Each drilling mud used in the study and sediments from the study site were analyzed in the laboratory for chemical and physical characteristics. Potential water quality impacts were simulated by the EPA-COE elutriation test procedure. Mud toxicity was measured by acute and chronic bioassays with Mysidopsis bahia, Mercenaria mercenaria, and Nereis virens.^ For the field study, a relatively pristine, shallow (1.2 m) estuary (Christmas Bay, TX) without any drilling activity for the last 30 years was chosen for the study site. After a three month baseline study, three stations were selected. Station 1 was an external control. At each treatment station (2, 3), mesocosms were constructed to enclose a 3.5 m$\sp3$ water column. Each treatment station included an internal control site also. Each in situ mesocosm, except the controls, was successively dosed at a mesocosm-specific dose (1:100; 1:1,000; or 1:10,000 v/v) with 4 field collected drilling muds (spud, nondispersed, lightly-treated, and heavily-treated lignosulfonate) in sequential order over 1.5 months. Twenty-four hours after each dose, water exchange was allowed until the next treatment. Station 3 was destroyed by a winter storm. After the last treatment, the enclosures were removed and the remaining sites monitored for 6 months. One additional site was similarly dosed (1:100 v/v) with clean dredged sediment from Christmas Bay for comparison between dredged sediments and drilling muds.^ Results of the analysis of the water samples and field measurements showed that water quality was impacted during the discharges, primarily at the highest dose (1:100 v/v), but that elevated levels of C, Cr (T,F), Cr$\sp{+3}$ (T, F), N, Pb, and Zn returned to ambient levels before the end of the 24 hour exposure period or immediately after water exchange was allowed (Al, Ba(T), Chlorophyll ABC, SS, %T). Barium, from the barite, was used as a geochemical tracer in the sediments to confirm estimated doses by mass balance calculations. Barium reached a maximum of 166x background levels at the high dose mesocosm. Barium levels returned to ambient or only slightly elevated levels at the end of the 6 month monitoring period due to sediment deposition, resuspension, and bioturbation. QA/QC results using blind samples consisting of lab standards and spiked samples for both water and sediment matrices were within acceptable coefficients of variation.^ In order to avoid impacts on water quality and sediment geochemistry in a shallow estuarine ecosystem, this study concluded that a minimal dilution of 1:1,000 (v/v) would be required in addition to existing regulatory constraints. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Influenza (the flu) is a serious respiratory illness that can cause severe complications, often leading to hospitalization and even death. Influenza epidemics occur in most countries every year, usually during the winter months. Despite recommendations from the Centers for Disease Control and Prevention (CDC) and efforts by health care institutions across the United States, influenza vaccination rates among health care workers in the United States remain low. How to increase the number of vaccinated health care workers is an important public health question and is examined in two journal articles included here. ^ The first journal article evaluates the effectiveness of an Intranet intervention in increasing the proportion of health care workers (HCWs) who received influenza vaccination. Hospital employees were required go to the hospital's Intranet and select "vaccine received," "contraindicated," or "declined" from the online questionnaire. Declining employees automatically received an online pop-up window with education about vaccination; managers were provided feedback on employees' participation rates via e-mail messages. Employees were reminded of the Intranet requirement in articles in the employee newsletter and on the hospital's Intranet. Reminders about the Intranet questionnaire were provided through managers and newsletters to the HCWs. Fewer than half the employees (43.7%) completed the online questionnaire. Yet the hospital witnessed a statistically significant increase in the percentage of employees who received the flu vaccine at the hospital – 48.5% in the 2008-09 season as compared to 36.5%, 38.5% and 29.8% in the previous three years (P < 0.05). ^ The second article assesses current interventions employed by hospitals, health systems and nursing homes to determine which policies have been the most effective in boosting vaccination rates among American health care workers. A systematic review of research published between January 1994 and March 2010 suggests that education is necessary but not usually sufficient to increase vaccine uptake. Education about the flu and flu vaccines is most effective when complemented with easy access and making the vaccine free, although this combination may not be sufficient to achieve the desired vaccination levels among HCWs. The findings point toward adding incentives for HCWs to get vaccinated and requiring them to record their vaccination status on a declination/consent form – either written or electronic. ^ Based on these findings, American health care organizations, such as hospitals, nursing homes, and long-term care facilities, should consider using online declination forms as a method for increasing influenza vaccination rates among their employees. These online forms should be used in conjunction with other policies, including free vaccine, mobile distribution and incentives. ^ To further spur health care organizations to adopt policies and practices that will raise influenza vaccination rates among employees, The Joint Commission – an independent, not-for- profit organization that accredits and certifies more than 17,000 health care organizations and programs in the United States – should consider altering its standards. Currently, The Joint Commission does not require signed declination forms from employees who eschew vaccination; it only echoes the CDC's recommendations: "Health care facilities should require personnel who refuse vaccination to complete a declination form." Because participation in Joint Commission accreditation is required for Medicare reimbursement, action taken by the Joint Commission to require interventions such as mandatory declination/consent forms might result in immediate action by health care organizations to follow these new standards and lead to higher vaccination rates among HCWs.^ 1“Frequently Asked Questions for H1N1 and Seasonal Influenza.” The Joint Commission - Infection Control: http://www.jointcommission.org/PatientSafety/InfectionControl/h1n1_faq.htm. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^