3 resultados para 40-1
em DigitalCommons@The Texas Medical Center
Resumo:
This study assessed the impact of cigarette advertising on adolescent susceptibility to smoking in the Hempstead and Hitchcock Independent School Districts. A convenience sample of 217 youths, 10-19 years of age was recruited in the study. Students completed both a paper-and-pencil and a computer-aided questionnaire in April 1996. Adolescents were defined as susceptible to smoking if they could not definitely rule out the possibility of future smoking. For the analysis, an index was devised: a 5-point index of an individual's receptivity to cigarette advertising. The index is determined by the number of positive responses to five survey items (recognizing cigarette brand logos, recognizing cigarette advertisement's pictures, recognizing cigarette brand slogans, evaluating adolescent attitudes toward cigarette advertising, and the degree to which adolescents were exposed to cigarette advertisements). Using logistic regression, we assessed the independent importance of the index in predicting susceptibility to smoking and ever smoking after adjusting for sociodemographic variables, perceived school performance and family composition. Of students surveyed, 54.4% of students appeared to have started the smoking uptake process as measured by susceptibility to smoking. Camel was recognized by the majority of students (88%), followed by Marlboro (41.5%) and Newport (40.1%). The pattern for recognition of the cigarette advertisements was the same as the pattern of market for cigarette. Advertisement featuring the cartoon character Joe Camel was significantly more appealing to adolescents than were advertisements with human models, with animal models, and with text only (p $<$ 0.001). Text only advertisement was significantly less appealing than other types of advertisements. The cigarette advertisement with White models (Marlboro) had significantly higher appeal to White students than to African-American students (p $<$ 0.001). The cigarette advertisement featuring African-American models (Virginia Slims) was significantly more appealing to African-American students than other ethnic groups (p $<$ 0.001). Receptivity to cigarette advertising was to be an important concurrent predictor of past smoking experience and intention to smoke in the future. Adolescents who scored in the fourth quartile of the Index of Receptivity to Cigarette Advertising were 7.54 (95% confidence interval (CI) = 1.92-29.56) times as likely to be susceptible to smoking, and were 4.56 (95% CI = 1.55-13.38) times as likely to have tried smoking, as those who scored in the first quartile of the Index. The findings confirmed the hypothesis that cigarette advertising may be a strong current influence in encouraging adolescents to initiate the smoking uptake process than sociodemographic variables, perceived school performance and family composition. ^
Resumo:
Results from epidemiologic studies suggest that persons working in occupations with presumed electric and magnetic field (EMF) exposures are at increased risk of brain cancer. This study utilized data from a completed, population-based, interview case-control study of central nervous system (CNS) tumors and employment in the petrochemical industry to test the hypothesis that employment in EMF-related occupations increases CNS tumor risk. A total of 375 male residents of the Texas-Louisiana Gulf Coast Area, age 20 to 79, with primary neuroglial CNS tumors diagnosed during the period 1980-84 were identified. A population-based comparison group of 450 age, race and geographically matched males was selected. Occupational histories and potential risk factor data were collected via personal interviews with study subjects or their next-of-kin.^ Adjusted odds ratios were less than 1.0 for persons ever employed in an electrical occupation (OR = 0.65; 95% CI = 0.40-1.09) or whose usual occupation was electrical (OR = 0.76; 95% CI = 0.33-1.73). Relative risk estimates did not increase significantly as time since first employment or duration of employment increased. Examination of CNS tumor risk by high (OR = 0.80), medium (OR = 0.88) and low (OR = 0.45) exposure categories for persons whose usual occupation was electrical did not indicate a dose-response pattern. In addition, the mean age of exposed cases was not significantly younger than that for unexposed cases. Analysis of risk by probability of exposure to EMFs showed non-significant elevations in the adjusted odds ratio for definite exposed workers defined by their usual occupation (OR = 1.78; 95% CI = 0.70-4.51) and ever/never employed status (OR = 1.54; 95% CI = 0.17-4.91).^ These findings suggest that employment in occupations with presumed EMF exposures does not increase CNS tumor risk as was suggested by previous investigations. The results of this study also do not support the EMF-tumor promotion hypothesis. ^
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^