6 resultados para 270304 Infectious Agents
em DigitalCommons@The Texas Medical Center
Resumo:
Occupational asthma is the most common form of reported occupational respiratory disease in many industrialized countries. Recent studies show that environmental exposures account for up to 40% of the cases of asthma and that 2% to 15% of all cases of asthma are attributable to occupational exposures. In the dental workplace, dental hygienists are exposed to hazardous substances. Among these hazards are respiratory sensitizers, irritants and infectious agents. A cross-sectional study of Texas dental hygienists was conducted to assess the prevalence of occupational asthma. Registered dietitians were surveyed as a comparison group, because this group is similar in demographic makeup to dental hygienists, but conducts no clinical treatment with associated hazardous exposures. Neither the questionnaire survey nor the cover letter revealed the focus of this investigation. Three hundred and thirty five dental hygienists licensed to practice in the state of Texas as of January 1, 1999, and 320 dietitians that are also licensed by the state of Texas were randomly selected. (Abstract shortened by UMI.)^
Resumo:
The biological safety profession has historically functioned within an environment based on recommended practices rather than regulations, so summary data on compliance or noncompliance with recommended practices is largely absent from the professional literature. The absence of safety performance outcome data is unfortunate since the concept of biosafety containment is based on a combination of facility based controls and workplace practices, and persistent failures in either type of controls could ultimately result in injury or death. In addition, the number of laboratories requiring biosafety containment is likely to grow significantly in the coming years in the wake of the terrorist events of 2001. In this study, the outcomes of 768 biosafety level 2 (BSL-2) safety surveys were analyzed for commonalities and trends. Items of non-compliance noted were classified as facility related or practice related. The most frequent item of noncompliance encountered was the failure to re-certify biosafety cabinetry. Not surprisingly, the preponderance of the other frequent items of non-compliance encountered were practice related, such as general housekeeping orderly, changes in compliance levels, as well as establish trends in the elements of items of non-compliance during the sequential survey period. The findings described in this study are significant because, for the first time, the outcomes of compliance with recommended biosafety practices can be characterized and thus used as the basis for focused interventions. Since biosafety is heavily reliant on adherence to specific safety practices, the ability to focus interventions on objectively identified practice-related items of non-compliance can assist in the reduction of worker risk in this area experiencing tremendous growth. The information described is also of heighten importance given the number of workplaces expected to involve potentially infectious agents in the coming years. ^
Resumo:
Acute diarrhea is the most common medical problem in the developing countries. Infectious agents are responsible for a majority of cases of acute diarrhea. Knowing the cause of acute diarrhea is important to developing plans for disease prevention, control and therapy. Acute diarrhea is caused by many viruses, bacteria and parasites. ^ Travelers to developing countries of the world commonly develop diarrhea as a result of eating contaminated food or drinking contaminated water. About 30-50% of travelers who travel from industrialized countries like United States to the developing countries are at risk of developing diarrhea. High risk areas for travelers' diarrhea are Mexico, Latin America and Southeast Asia. Public restaurants are the common sites for exposure to this type of food-borne infectious disease in travelers. Food becomes contaminated when they are handled by people with fecal content on their hands. ^ The importance of Diffusely Adherent Escherichia Coli (DAEC) in travelers to these areas has not been well studied. Some of the studies looking at DAEC have shown the organism to be present in children without symptoms. Other studies have shown a relationship between DAEC infection and presence of symptoms. I have selected this topic because the patho-physiological processes in DAEC infection that allow intestinal and extra-intestinal infections to develop are not fully understood. DAEC related acute diarrhea is a relatively new topic of public health significance. There is a limited number of studies regarding the virulence and pathogenic mechanisms of DAEC. The presumed virulence factor of the organism is diffuse attachment to the intestinal lining of the infected host. However more research needs to be done to identify the pathogenic mechanisms and virulence factors associated with DAEC infection for better treatment planning and diarrhea prevention. ^
Resumo:
Background. In Dr. Mel Greaves "delayed-infection hypothesis," postponed exposure to common infections increases the likelihood of childhood cancer. Hygienic advancements in developed countries have reduced children's exposure to pathogens and children encounter common infectious agents at an older age with an immune system unable to deal with the foreign antigens. Vaccinations may be considered to be simulated infections as they prompt an antigenic response by the immune system. Vaccinations may regulate the risk of childhood cancer by modulating the immune system. The aim of the study was to determine if children born in Texas counties with higher levels of vaccination coverage were at a reduced risk for childhood cancer.^ Methods. We conducted a case-control study to examine the risk of childhood cancers, specifically leukemia, brain tumors, and non-Hodgkin lymphoma, in relation to vaccination rates in Texas counties. We utilized a multilevel mixed-effects regression model of the individual data from the Texas Cancer Registry (TCR) with group-level exposure data (i.e., the county- and public health region-level vaccination rates).^ Results. Utilizing county-level vaccination rates and controlling for child's sex, birth year, ethnicity, birth weight, and mother's age at child's birth the hepatitis B vaccine revealed negative associations with developing all cancer types (OR = 0.81, 95% CI: 0.67–0.98) and acute lymphoblastic leukemia (ALL) (OR = 0.63, 95% CI: 0.46–0.88). The decreased risk for ALL was also evident for the inactivated polio vaccine (IPV) (OR = 0.67, 95% CI: 0.49–0.92) and 4-3-1-3-3 vaccination series (OR = 0.62, 95% CI: 0.44-0.87). Using public health region vaccine coverage levels, an inverse association between the Haemophilus influenzae type b (Hib) vaccine and ALL (OR: 0.58; 95% CI: 0.42–0.82) was present. Conversely, the measles, mumps, and rubella (MMR) vaccine resulted in a positive association with developing non-Hodgkin lymphoma (OR = 2.81, 95% CI: 1.27–6.22). ^
Resumo:
Obesity has a complex, multi-factorial etiology. Infectious agents have recently emerged as a possible contributor to the current obesity epidemic. Seven viruses have demonstrated an association with obesity in animals; however, Adenovirus-36 (Ad-36) is the only known virus associated with obesity in humans. The primary aim of this research was to determine the association between Ad-36 infection and the expression of obesity related hormones in children. Additionally, this study proposed to compare the mean three year change in the level of obesity related hormones between Ad-36 positive and negative children. This study utilized pilot data collected from 98 children at baseline and year three of the Project Heartbeat! cohort. Fasting serum samples were analyzed for the concentration of adiponectin, insulin and leptin. The crude analysis uncovered Ad-36 positive children had significantly lower mean concentrations of insulin (p=0.039) and leptin (p=0.038) at baseline compared to Ad-36 negative children. The results of the adjusted analysis indicated the leptin association with Ad-36 infection at baseline was statistically significant even after controlling for age, sex, ethnicity, and BMI percentile. The longitudinal evaluation revealed individuals with a history of Ad-36 infection experienced a larger mean decrease in adiponectin, a larger mean increase in leptin, and a smaller mean increase in insulin levels over a three year period compared to individuals without a history of infection. These results suggest Ad-36 infection may produce changes in hormone expression. The only statistically significant findings in the crude and adjusted longitudinal analysis occurred at baseline when the children were younger, suggesting physical changes that occur during sexual maturation may mask or enhance Ad-36 induced changes in hormone expression. Furthermore, the longitudinal analysis revealed the duration and course of Ad-36 infection may influence changes in the expression of obesity-related hormones. Taken together, the results of this pilot study are suggestive of an association between Ad-36 infection and the expression of obesity-related hormones.^
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^