113 resultados para Commission for Evaluation of Medical Events


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Children with cystic fibrosis are at increased risk of seasonal influenza associated complications, which makes them a judicious target of interventions designed to increase influenza vaccination rates. The Baylor College of Medicine/Texas Children's Hospital Pediatric Cystic Fibrosis (BCM/TCH CF) Care Center implemented an enhanced multi-component initiative designed to increase influenza vaccination rates in its patient population during the 2011-2012 influenza season. We evaluated the impact of specific components of this intervention on vaccination rates among the clinic's patient population via a historical medical chart review and examined the relationship between vaccination status and the number of pulmonary exacerbations requiring hospital admission during the influenza season. The multi-component intervention was comprised of providing influenza free of charge in the CF Care Center, reminders via phone call and letters, and drive through influenza vaccine clinics on nights and weekends. The intervention to increase influenza vaccination rates led to overall improved vaccination rates among the patients at the BCM/TCH CF Care Center, increasing from 90% adherence observed during the 2010-2011 season to 94% adherence during the 2011-2012 season. The availability of free influenza vaccine in the CF Care Center, combined with reminders about being vaccinated early in the season proved to be the most effective practices for improving the vaccination rate in the CF Care Center.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study purpose was to analyze the effects Integrated Health Solutions (IHS), an employee wellness program that has been implemented for one year on the corporate campus of a major private sector petrochemical company in Houston, TX, has on employee health. ^ Chronic diseases are the leading causes of morbidity and mortality in the United States and are the most preventable of all health problems. The costs of chronic diseases in the working-age adult population include not only health problems and a decrease in quality of life, but also an increase the cost of health care and costs to businesses and employers, both directly and indirectly. These emerging costs to employers as well as the fact that adults now spend the majority of waking hours at the office have increased the interest in worksite health promotion programs that address many of the behavioral factors that lead to chronic conditions. Therefore, implementing and evaluating programs that are aimed at promoting health and decreasing the prevalence of chronic diseases at worksites is very important. ^ Data came from existing data that were collected by IHS staff during employee biometric screenings at the company in 2010 and 2011. Data from employees who participated in screenings in both 2010 and 2011 were grouped into a cohort by IHS staff. ^ One-tailed t-tests were conducted to determine if there were significant improvements in the biometric measures of body fat percentage, BMI, waist circumference, systolic and diastolic blood pressures, total, HDL, and LDL cholesterol levels, triglycerides, blood glucose levels, and cardiac risk ratios. Sensitivity analysis was conducted to determine if there were differences in program outcomes when stratified by age, gender, job type, and time between screenings. ^ Mean differences for the variables from 2010 to 2011 were small and not always in the desired direction for health improvement indicators. Through conducting t-tests, it was found that there were significant improvements in HDL, cardiac risk ratio, and glucose levels. There were significant increases in cholesterol, LDL, and diastolic blood pressures. For the IHS program, it appears that gender, job type, and time between screenings were possible modifiers of program effectiveness. When program outcome measures were stratified by these factors, results suggest that corporate employees had better outcomes than field employees, males had better outcomes overall than females, and more positive program effects were seen for employees with less time between their two screenings. ^ Recommendations for the program based on the results include ensuring validity of instruments and initial and periodic training of measurement procedures and equipment handling, using normative data or benchmarks to decrease chances for biased estimates of program effectiveness, measuring behaviors as well as biometric and physiologic statuses and changes, and collecting level of engagement data.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. This study was designed to evaluate the effects of the Young Leaders for Healthy Change program, an internet-delivered program in the school setting that emphasized health advocacy skills-development, on nutrition and physical activity behaviors among older adolescents (13–18 years). The program consisted of online curricular modules, training modules, social media, peer and parental support, and a community service project. Module content was developed based on Social Cognitive Theory and known determinants of behavior for older adolescents. ^ Methods. Of the 283 students who participated in the fall 2011 YL program, 38 students participated in at least ten of the 12 weeks and were eligible for this study. This study used a single group-only pretest/posttest evaluation design. Participants were 68% female, 58% white/Caucasian, 74% 10th or 11th graders, and 89% mostly A and/or B students. The primary behavioral outcomes for this analysis were participation in 60-minutes of physical activity per day, 20-minutes of vigorous- or moderate- intensity physical activity (MVPA) participation per day, television and computer time, fruit and vegetable (FV) intake, sugar-sweetened beverage intake, and consumption of breakfast, home-cooked meals, and fast food. Other outcomes included knowledge, beliefs, and attitudes related to healthy eating, physical activity, and advocacy skills. ^ Findings. Among the 38 participants, no significant changes in any variables were observed. However, among those who did not previously meet behavioral goals there was an 89% increase in students who participated in more than 20 minutes of MVPA per day and a 58% increase in students who ate home-cooked meals 5–7 days per week. The majority of participants met program goals related to knowledge, beliefs, and attitudes prior to the start of the program. Participants reported either maintaining or improving to the goal at posttest for all items except FV intake knowledge, taste and affordability of healthy foods, interest in teaching others about being healthy, and ease of finding ways to advocate in the community. ^ Conclusions. The results of this evaluation indicated that promoting healthy behaviors requires different strategies than maintaining healthy behaviors among high school students. In the school setting, programs need to target the promotion and maintenance of health behaviors to engage all students who participate in the program as part of a class or club activity. Tailoring the program using screening and modifying strategies to meet the needs of all students may increase the potential reach of the program. The Transtheoretical Model may provide information on how to develop a tailored program. Additional research on how to utilize the constructs of TTM effectively among high school students needs to be conducted. Further evaluation studies should employ a more expansive evaluation to assess the long-term effectiveness of health advocacy programming.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since interferon-gamma release assays (IGRAs) were introduced in the 2000's, tuberculin skin testing (TST) and IGRAs have been used in various latent tuberculosis infection (LTBI) screening settings. IGRAs are laboratory-based tests and are considered not to be affected by previous Bacille de Calmette et Guérin (BCG) vaccination; however, they are more costly when compared directly with TST, which does not require specimen processing in a laboratory. This study aimed to examine TST and two types of IGRAs, QuantiFERON-TB Gold in Tube (QFT-GIT) and T-SPOT. TB (TSPOT), from an economic viewpoint. Firstly, a systematic literature review was conducted to identify cost related analyses of LTBI screening. Secondly, specific cost information detailing each test's items and labor was collected from an LTBI screening program of health care workers in Houston, and the cost of each test was computed. Thirdly, using the computed cost estimate of each test, cost-effectiveness analyses were conducted to compare TST and IGRAs.^ A literature search showed that a limited number of studies have been conducted, but the IGRA's economic advantages were common among studies. Cost analyses showed that IGRAs were much more costly than TST. The results were consistent with previous studies. In cost-effectiveness analyses, where test cost and consequential TB-related cost were considered, IGRAs showed variable advantages over TST depending on the targeted population. When only non BCG-vaccinated people were considered, TST was the least costly option among the three tests. On the other hand, when only BCG-vaccinated people were considered, IGRAs were less costly options. These results were mostly consistent even with varying assumption parameters.^ IGRAs can be more costly than TST, but their economic disadvantages are alleviated when the target population was BCG-vaccinated. Based on current knowledge, IGRAs may be recommended in a population where the BCG history is mixed. Additional studies are needed to better understand IGRA's reliability among low-incidence and low-risk populations in which background TB prevalence is low.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared initial year trends in prenatal care and birth outcomes of women enrolled in the Texas Children's Health Insurance Program (CHIP) Perinatal program to trends in Medicaid program women. The study utilized claims data from Community Health Choice (CHC), a health plan in Harris County, Texas that provides coverage to both populations. Quarterly data was analyzed and compared for the first two years of the CHIP Perinatal program (2007-2008) to determine if outcome trends for the CHIP program improved over the outcome trends seen with those enrolled in Medicaid. Study findings indicate an increase in the quarterly prenatal care utilization for the CHIP Perinatal population from 2007 to 2008 and the associated birth weights of babies delivered also had marginal improvements during the same timeframe. Enrollees in Medicaid continued to have overall better outcomes than those enrolled within the CHIP Perinatal program. However, the study showed that the rate of improvement in both prenatal care utilization and birth outcomes were greater for the CHIP Perinatal enrollees than those enrolled in Medicaid. ^ The majority of these improvements were significant when comparing each coverage program and from year to year. Lastly, the study showed that there was a correlation between prenatal care utilization and birth outcomes. However, further analysis of the data could not conclusively indicate that access to prenatal care services provided by the CHIP Perinatal program contributed to the increases observed in utilization and birth outcomes for the study's sample population.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CHARACTERIZATION OF THE COUNT RATE PERFORMANCE AND EVALUATION OF THE EFFECTS OF HIGH COUNT RATES ON MODERN GAMMA CAMERAS Michael Stephen Silosky, B.S. Supervisory Professor: S. Cheenu Kappadath, Ph.D. Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and measurement of system dead time (τ) is important for quantitative SPECT. The CRP of three modern gamma cameras was characterized using established methods (Decay and Dual Source) under a variety of experimental conditions. For the Decay method, input count rate was plotted against observed count rate and fit to the paralyzable detector model (PDM) to estimate τ (Rates method). A novel expression for observed counts as a function of measurement time interval was derived and the observed counts were fit to this expression to estimate τ (Counts method). Correlation and Bland-Altman analysis were performed to assess agreement in estimates of τ between methods. The dependencies of τ on energy window definition and incident energy spectrum were characterized. The Dual Source method was also used to estimate τ and its agreement with the Decay method under identical conditions and the effects of total activity and the ratio of source activities were investigated. Additionally, the effects of count rate on several performance metrics were evaluated. The CRP curves for each system agreed with the PDM at low count rates but deviated substantially at high count rates. Estimates of τ for the paralyzable portion of the CRP curves using the Rates and Counts methods were highly correlated (r=0.999) but with a small (~6%) difference. No significant difference was observed between the highly correlated estimates of τ using the Decay or Dual Source methods under identical experimental conditions (r=0.996). Estimates of τ increased as a power-law function with decreasing ratio of counts in the photopeak to the total counts and linearly with decreasing spectral effective energy. Dual Source method estimates of τ varied as a quadratic with the ratio of the single source to combined source activities and linearly with total activity used across a large range. Image uniformity, spatial resolution, and energy resolution degraded linearly with count rate and image distorting effects were observed. Guidelines for CRP testing and a possible method for the correction of count rate losses for clinical images have been proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In line with the long-standing emphasis in the human services on involving clients in program evaluation, in this essay I focus on principles and strategies for involving parents in evaluation of family preservation services. In particular, I delineate the crucial roles that parents can play as partners in the helping process within a family-centered context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in which dosimeter response is not inhibited by oxygen, was found to make up roughly one fourth of the total dosimeter volume. Delivering a dose across multiple fractions was found to yield a greater response than delivering the same dose in a single irradiation. The dosimeter was found to accurately measure a dose distribution produced by overlapping photon fields, yielding gamma pass rates of 95.4% and 93.1% from two planar gamma analyses. Proton irradiations were performed for measurements of proton dose and LET. Initial irradiations performed through the side of a dosimeter led to OCT artifacts. Gamma pass rates of 85.7% and 89.9% were observed in two planar gamma analyses. In irradiations performed through the base of a dosimeter, gel response was found to increase with height in the dosimeter, even in areas of constant dose. After a correction was applied, gamma pass rates of 94.6% and 99.3% were observed in two planar gamma analyses. Absolute dose measurements were substantially higher (33%-100%) than the delivered doses for proton irradiations. Issues encountered while calibrating the LET-Meter gel restricted analysis of the LET measurement data to the SOBP of a proton beam. LET-Meter overresponse was found to increase linearly with track-average LET across the LET range that could be investigated (1.5 keV/micron – 3.5 keV/micron).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This dissertation evaluated three aspects of the Centers for Medicare and Medicaid Services' Hospital Acquired Conditions and Present on Admission Indicator Reporting program (HACPOA program) to produce three journal articles for publication. ^ Methods: All payer admission records from state inpatient databases from Arizona, New Jersey and Washington states were analyzed for the year 2008. However some analyses required a sample of adult only Medicare patients in the first two studies. California's inpatient data (2004 – 2010) was also analyzed in the third study to examine the reporting and non-payment program elements' impact on the incidence of hospital acquired conditions. ^ Results: Majority diagnoses reported in inpatient prospective payment systems hospitals were present on admission. However, some diagnoses are still coded as "not present on admission" and "insufficient documentation to determine whether or not conditions are present on admission or not". This is important because it reveals that hospital complications still occur in hospitals. Hospital fall and trauma injuries were the most common hospital acquired conditions observed in this study. Predictors of hospital fall injuries include age, gender, number of diagnoses, number of procedures, number of chronic conditions while predictors of hospital trauma injuries include number of e-codes, number of diagnoses and the presence of chronic conditions on a patient's admission records. Finally, the implementation of the present on admission reporting requirement increased reports of certain hospital acquired conditions while the non-payment policy element in the Hospital Acquired Conditions program reduced the incidence of hospital fall and trauma injuries in particular. ^ Conclusion: The implementation of the Hospital Acquired Conditions and Present on Admission Indicator Reporting program has made the state inpatient database a more useful source of data capable of now identifying hospital complications. The reporting and nonpayment program elements in the HACPOA program have also impacted the incidence of hospital acquired conditions. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in pre-kindergarten to third grade in Austin, TX during a summer day camp in 2007.^ Methods: Data was collected from child participants via teacher and researcher administered tests at pretest, posttest (immediately after the completion of the fire safety module), and at a 3 week follow-up to asses retention. In addition, a self-administered questionnaire was collected from parents pre- and post-intervention to assess home-related fire/burn risk factors. Paired t-tests were conducted using STATA 12.0 to evaluate pretest, posttest, and retention test mean scores as well as mean fire safety rules listed by grade group. McNemar's test was used to determine if there was a difference in fire-related risk factors as reported by the parents of the participants before and after the intervention. Only those who had paired data for the tests/surveys being compared were included in the analysis.^ Results: The first/second grade group and the third grade group scored significantly higher on fire safety knowledge on the posttest compared to the pretest (p<0.0001 for both groups). However, there was no significant change in knowledge scores for the pre-kindergarten to kindergarten group (p=0.14). Among the first/second grade group, knowledge levels did not significantly decline between the posttest and retention test (p=0.25). However, the third grade group had significantly lower fire safety knowledge scores on the retention test compared to the posttest (p<0.001). A similar increase was seen in the amount of fire safety rules listed after the intervention (p<0.0001 between pre and posttest for both the first/second grade and third grade groups), with no decline from the posttest to the retention test (p=0.50) for the first/second grade group, but a significant decline in the third grade group (p=0.001). McNemar's chi-square test showed a significant increase in the percentage of participants' parents reporting smoke detector testing on a regular basis and having a fire escape plan for their family after the intervention (p=0.01 and p<0.0001, respectively). However, there was no significant change in the frequency of reports of the child playing in the kitchen while the parent cooks or the house/apartment having a working smoke detector.^ Conclusion: We found that general fire safety knowledge improved and the number of specific fire safety rules increased among the first to third grade children who participated in the Danger Rangers fire safety program. However, it did not significantly increase general fire safety knowledge among the pre-k/k group. This study also showed that a program targeted towards children has the potential to influence familial risk factors by proxy. The Danger Rangers Fire Safety Curriculum should be further evaluated by conducting a randomized controlled trial, using valid measures that assess fire safety attitudes, beliefs, behaviors, as well as fire/burn related outcomes.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last decade, adverse events and medical errors have become a main focus of interest for the standards of quality and safety in the U.S. healthcare system (Weinstein & Henderson, 2009). Particularly when a medical error occurs, the disclosure of medical errors and its practices have become a focal point of the healthcare process. Patients and family members who have experienced a medical error might be able to provide knowledge and insight on how to improve the disclose process. However, patient and family member are not typically involved in the disclosure process, thus their experiences go unnoticed. ^ The purpose of this research was to explore how best to include patients and family members in the disclosure process regarding a medical error. The research consisted of 28 qualitative interviews from three stakeholder groups: Hospital Administrators, Clinical Service Providers, and Patients and Family Members. They were asked for their ideas and suggestions on how best to include patients and family members in the disclosure process. Framework Analysis was used to analyze this data and find prevalent themes based on the primary research question. A secondary aim was to index categories created based on the interviews that were collected. Data was used from the Texas Disclosure and Compensation Study with Dr. Eric Thomas as the Principal Investigator. Full acknowledgement of access to this data is given to Dr. Thomas. ^ The themes from the research revealed that each stakeholder group was interested and open to including patients and family members in the disclosure process and that the disclosure process should not be a "one-way" avenue. The themes gave many suggestions regarding how to best include patients and family members in the disclosure process of a medical error. Secondary aims revealed several ways to assess the ideas and suggestion given by the stakeholders. Overall, acceptability of getting the perspective of patients and family members was the most common theme. Comparison of each stakeholder group revealed that including patients and family members would be beneficial to improving hospital disclosure practices. ^ Conclusions included a list of recommendations and measureable appropriate strategies that could provide hospital with key stakeholders insights on how to improve their disclosure process. Sharing patients and family members experience with healthcare providers can encourage a shift in culture where patients are valued and active in participating in hospital practices. To my knowledge, this research is the very first of its kind and moves the disclosure process conversation forward in a patient-family member inclusion direction that will assist in improving disclosure practices. Future research should implement and evaluate the success of the various inclusion strategies.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With continuous new improvements in brachytherapy source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters to establish PRESAGE® as a suitable brachytherapy dosimeter. The new AgX100 125I seed model (Theragenics Corporation) was then characterized using PRESAGE® following the TG-43 protocol. PRESAGE® dosimeters are solid, polyurethane-based, 3D dosimeters doped with radiochromic leuco dyes that produce a linear optical density response to radiation dose. For this project, the radiochromic response in PRESAGE® was captured using optical-CT scanning (632 nm) and the final 3D dose matrix was reconstructed using the MATLAB software. An Amersham 6711 seed with an air-kerma strength of approximately 9 U was used to irradiate two dosimeters to 2 Gy and 11 Gy at 1 cm to evaluate dose rates in the r=1 cm to r=5 cm region. The dosimetry parameters were compared to the values published in the updated AAPM Report No. 51 (TG-43U1). An AgX100 seed with an air-kerma strength of about 6 U was used to irradiate two dosimeters to 3.6 Gy and 12.5 Gy at 1 cm. The dosimetry parameters for the AgX100 were compared to the values measured from previous Monte-Carlo and experimental studies. In general, the measured dose rate constant, anisotropy function, and radial dose function for the Amersham 6711 showed agreements better than 5% compared to consensus values in the r=1 to r=3 cm region. The dose rates and radial dose functions measured for the AgX100 agreed with the MCNPX and TLD-measured values within 3% in the r=1 to r=3 cm region. The measured anisotropy function in PRESAGE® showed relative differences of up to 9% with the MCNPX calculated values. It was determined that post-irradiation optical density change over several days was non-linear in different dose regions, and therefore the dose values in the r=4 to r=5 cm regions had higher uncertainty due to this effect. This study demonstrated that within the radial distance of 3 cm, brachytherapy dosimetry in PRESAGE® can be accurate within 5% as long as irradiation times are within 48 hours.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.