35 resultados para medical treatment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of effective treatments for opioid dependence is of great importance given the devastating consequences of the disease. Pharmacotherapies for opioid addiction include opioid agonists, partial agonists, opioid antagonists, and alpha-2-adrenergic agonists, which are targeted toward either detoxification or long-term agonist maintenance. Agonist maintenance therapy is currently the recommended treatment for opioid dependence due to its superior outcomes relative to detoxification. Detoxification protocols have limited long-term efficacy, and patient discomfort remains a significant therapy challenge. Buprenorphine's effectiveness relative to methadone remains a controversy and may be most appropriate for patients in need of low doses of agonist treatment. Buprenorphine appears superior to alpha-2 agonists, however, and office-based treatment with buprenorphine in the USA is gaining support. Studies of sustained-release formulations of naltrexone suggest improved effectiveness for retention and sustained abstinence; however, randomized clinical trials are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To examine the relationships between physical growth and medications prescribed for symptoms of attention-deficit hyperactivity disorder in children with HIV. METHODS: Analysis of data from children with perinatally acquired HIV (N = 2251; age 3-19 years), with and without prescriptions for stimulant and nonstimulant medications used to treat attention-deficit hyperactivity disorder, in a long-term observational study. Height and weight measurements were transformed to z scores and compared across medication groups. Changes in z scores during a 2-year interval were compared using multiple linear regression models adjusting for selected covariates. RESULTS: Participants with (n = 215) and without (n = 2036) prescriptions were shorter than expected based on US age and gender norms (p < .001). Children without prescriptions weighed less at baseline than children in the general population (p < .001) but gained height and weight at a faster rate (p < .001). Children prescribed stimulants were similar to population norms in baseline weight; their height and weight growth velocities were comparable with the general population and children without prescriptions (for weight, p = .511 and .100, respectively). Children prescribed nonstimulants had the lowest baseline height but were similar to population norms in baseline weight. Their height and weight growth velocities were comparable with the general population but significantly slower than children without prescriptions (p = .01 and .02, respectively). CONCLUSION: The use of stimulants to treat symptoms of attention-deficit hyperactivity disorder does not significantly exacerbate the potential for growth delay in children with HIV and may afford opportunities for interventions that promote physical growth. Prospective studies are needed to confirm these findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many clients who undergo methadone maintenance (MM) treatment for heroin and other opiate dependence prefer abstinence from methadone. Attempts at methadone detoxification are often unsuccessful, however, due to distressing physical as well as psychological symptoms. Outcomes from a MM client who voluntarily participated in an Acceptance and Commitment Therapy (ACT) - based methadone detoxification program are presented. The program consisted of a 1-month stabilization and 5-month gradual methadone dose reduction period, combined with weekly individual ACT sessions. Urine samples were collected twice weekly to assess for use of illicit drugs. The participant successfully completed the program and had favorable drug use outcomes during the course of treatment, and at the one-month and one-year follow-ups. Innovative behavior therapies, such as ACT, that focus on acceptance of the inevitable distress associated with opiate withdrawal may improve methadone detoxification outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Methicillin (meticillin)-susceptible Staphylococcus aureus (MSSA) strains producing large amounts of type A beta-lactamase (Bla) have been associated with cefazolin failures, but the frequency and impact of these strains have not been well studied. Here we examined 98 MSSA clinical isolates and found that 26% produced type A Bla, 15% type B, 46% type C, and none type D and that 13% lacked blaZ. The cefazolin MIC(90) was 2 microg/ml for a standard inoculum and 32 microg/ml for a high inoculum, with 19% of isolates displaying a pronounced inoculum effect (MICs of >or=16 microg/ml with 10(7) CFU/ml) (9 type A and 10 type C Bla producers). At the high inoculum, type A producers displayed higher cefazolin MICs than type B or C producers, while type B and C producers displayed higher cefamandole MICs. Among isolates from hemodialysis patients with MSSA bacteremia, three from the six patients who experienced cefazolin failure showed a cefazolin inoculum effect, while none from the six patients successfully treated with cefazolin showed an inoculum effect, suggesting an association between these strains and cefazolin failure (P = 0.09 by Fisher's exact test). In summary, 19% of MSSA clinical isolates showed a pronounced inoculum effect with cefazolin, a phenomenon that could explain the cases of cefazolin failure previously reported for hemodialysis patients with MSSA bacteremia. These results suggest that for serious MSSA infections, the presence of a significant inoculum effect with cefazolin could be associated with clinical failure in patients treated with this cephalosporin, particularly when it is used at low doses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Compromised blood-spinal cord barrier (BSCB) is a factor in the outcome following traumatic spinal cord injury (SCI). Vascular endothelial growth factor (VEGF) is a potent stimulator of angiogenesis and vascular permeability. The role of VEGF in SCI is controversial. Relatively little is known about the spatial and temporal changes in the BSCB permeability following administration of VEGF in experimental SCI. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) studies were performed to noninvasively follow spatial and temporal changes in the BSCB permeability following acute administration of VEGF in experimental SCI over a post-injury period of 56 days. The DCE-MRI data was analyzed using a two-compartment pharmacokinetic model. Animals were assessed for open field locomotion using the Basso-Beattie-Bresnahan score. These studies demonstrate that the BSCB permeability was greater at all time points in the VEGF-treated animals compared to saline controls, most significantly in the epicenter region of injury. Although a significant temporal reduction in the BSCB permeability was observed in the VEGF-treated animals, BSCB permeability remained elevated even during the chronic phase. VEGF treatment resulted in earlier improvement in locomotor ability during the chronic phase of SCI. This study suggests a beneficial role of acutely administered VEGF in hastening neurobehavioral recovery after SCI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: High cost, poor compliance, and systemic toxicity have limited the use of pentavalent antimony compounds (SbV), the treatment of choice for cutaneous leishmaniasis (CL). Paromomycin (PR) has been developed as an alternative to SbV, but existing data are conflicting. METHODOLOGY/PRINCIPAL FINDINGS: We searched PubMed, Scopus, and Cochrane Central Register of Controlled Trials, without language restriction, through August 2007, to identify randomized controlled trials that compared the efficacy or safety between PR and placebo or SbV. Primary outcome was clinical cure, defined as complete healing, disappearance, or reepithelialization of all lesions. Data were extracted independently by two investigators, and pooled using a random-effects model. Fourteen trials including 1,221 patients were included. In placebo-controlled trials, topical PR appeared to have therapeutic activity against the old world and new world CL, with increased local reactions, when used with methylbenzethonium chloride (MBCL) compared to when used alone (risk ratio [RR] for clinical cure, 2.58 versus 1.01: RR for local reactions, 1.60 versus 1.07). In SbV-controlled trials, the efficacy of topical PR was not significantly different from that of intralesional SbV in the old world CL (RR, 0.70; 95% confidence interval, 0.26-1.89), whereas topical PR was inferior to parenteral SbV in treating the new world CL (0.67; 0.54-0.82). No significant difference in efficacy was found between parenteral PR and parenteral SbV in the new world CL (0.88; 0.56-1.38). Systemic side effects were fewer with topical or parenteral PR than parenteral SbV. CONCLUSIONS/SIGNIFICANCE: Topical PR with MBCL could be a therapeutic alternative to SbV in selected cases of the old world CL. Development of new formulations with better efficacy and tolerability remains to be an area of future research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to evaluate the impact of newer therapies on the highest risk patients with congenital diaphragmatic hernia (CDH), those with agenesis of the diaphragm. SUMMARY BACKGROUND DATA: CDH remains a significant cause of neonatal mortality. Many novel therapeutic interventions have been used in these infants. Those children with large defects or agenesis of the diaphragm have the highest mortality and morbidity. METHODS: Twenty centers from 5 countries collected data prospectively on all liveborn infants with CDH over a 10-year period. The treatment and outcomes in these patients were examined. Patients were followed until death or hospital discharge. RESULTS: A total of 1,569 patients with CDH were seen between January 1995 and December 2004 in 20 centers. A total of 218 patients (14%) had diaphragmatic agenesis and underwent repair. The overall survival for all patients was 68%, while survival was 54% in patients with agenesis. When patients with diaphragmatic agenesis from the first 2 years were compared with similar patients from the last 2 years, there was significantly less use of ECMO (75% vs. 52%) and an increased use of inhaled nitric oxide (iNO) (30% vs. 80%). There was a trend toward improved survival in patients with agenesis from 47% in the first 2 years to 59% in the last 2 years. The survivors with diaphragmatic agenesis had prolonged hospital stays compared with patients without agenesis (median, 68 vs. 30 days). For the last 2 years of the study, 36% of the patients with agenesis were discharged on tube feedings and 22% on oxygen therapy. CONCLUSIONS: There has been a change in the management of infants with CDH with less frequent use of ECMO and a greater use of iNO in high-risk patients with a potential improvement in survival. However, the mortality, hospital length of stay, and morbidity in agenesis patients remain significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Treatment retention is of paramount importance in cocaine treatment research as treatment completion rates are often 50% or less. Failure to retain cocaine patients in treatment has both significant research and clinical implications. In this paper we qualitatively and quantitatively demonstrate the inconsistency found across analyses of retention predictors in order to highlight the problem. First, a qualitative review of the published literature was undertaken to identify the frequency of predictors studied and their relations to treatment retention. Second, an empirical demonstration of predictor stability was conducted by testing a common set of variables across three similar 12-week cocaine clinical trials conducted by the same investigators in the same research clinic within a five-year period. Results of the literature review indicated inconsistently selected variables of convenience, widely varying statistical procedures, and discrepant findings of significance. Further, quantitative analyses resulted in discrepancies in variables identified as significant predictors of retention among the three studies. Potential sources of heterogeneity affecting the consistency of findings across studies and recommendations to improve the validity and generalizability of predictor findings in future studies are proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Inflammation is implicated in the development of cancer related fatigue (CRF). However there is limited literature on the mediators of inflammation (namely), cytokines and their receptors, associated with clinically significant fatigue and response to treatment. Methods: We reviewed 37 advanced cancer patients with fatigue (≥4/10), who participated in two Randomized Controlled Trials, of anti-inflammatory agents (Thalidomide and Dexamethasone) for CRF. Responders showed improvement in FACIT-F subscale at the end of study (Day 15). Baseline patient characteristics and symptoms were assessed by FACIT-F, ESAS; serum cytokines [IL-1β and receptor antagonist (IL-1RA), IL-6, IL-6R, TNF-α and sTNF-R1 and R2, IL-8, IL-10, IL-17] levels measured by Luminex. Data were analyzed using principal component analysis (PCA) [reporting cumulative variance (variance) for the first four components] to determine their association with fatigue and response to treatment. Results: Females were 54%. Mean (SD) was as follows for age, 61(14); baseline FACIT (F) scores, 21.4(8.6); ESAS Fatigue item, 6.5(1.9); and FACIT-F change, 6.4(9.7); ESAS (fatigue) change, -2 (2.41). Baseline median in pg/mL for IL-6, TNF-α, IL-1β were 31.9; 18.9; 0.55, respectively. Change in IL-6 negatively correlated with change in FACIT-F scores (p=0.02). Baseline CRF (FACIT-F score) was associated with IL-6, IL-6R and IL-17, Variance = 78% whereas IL-10, IL-1RA, TNF-α and IL-1β were associated with improvement of CRF, Variance=74%. Conversely, IL-6 and IL-8 were associated with no improvement or worsening of CRF, Variance= 93%. Conclusions: Change in IL-6 negatively correlated with change in FACIT-F scores. IL-6, IL-6R and IL-17 are associated with CRF while IL-6 and IL-8 were associated with no improvement of CRF. Further studies are warranted confirm our findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into the phantom material. Two treatment plans, proton passive scattering and proton spot scanning, were created. Thermoluminescent dosimeters (TLDs) and film were loaded into the phantom dosimetry insert. Each treatment plan was delivered three separate times. Each treatment plan passed our 5%/3mm criteria, with a reproducibility of ±3%. The hypothesis was accepted and the phantom was found to be suitable for remote audits of proton therapy treatment facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liposomes, also known as nontoxic, biodegradable, and non-immunogenic therapeutic delivery vehicles, have been proposed as a carrier for drugs and antitumor agents in cancer chemotherapy. Echogenic liposomes (ELIP) have the potential to entrap air or bioactive gas to enhance acoustic reflectivity in ultrasound and are used as a contrast agent. The innovative part of this study is based on a novel concept to encapsulate nitric oxide (NO) gas into ELIP, deliver it to breast cancer cells, and control its release via direct ultrasound exposure. Studies on the effect of NO in tumor biology have shown that a high levels of NO (> 300 nM) leads to cytostasis or apoptosis by decreasing the translation of several cell cycle proteins and stimulating cancer cell death by activating the p53 pathway. The central hypothesis is that NO gas can be packaged and delivered through a delivery methodology to breast cancer cells to facilitate tumor regression with minimal systemic toxicity. The primary goal of this thesis is to develop an echogenic liposomal solution that has the ability to encapsulate NO, to release NO locally upon ultrasound exposure, and to induce breast cancer cell death. NO-containing echogenic liposomes (NO-ELIP) were prepared by the freezing-under-pressure method previously developed in our laboratory. It was necessary to evaluate stability of NO-ELIP and release of NO from NO-ELIP by measuring echogenicity using intravascular ultrasound images. Breast cancer cell lines, MDA-MB-231 and MDA-MB-468, were selected to investigate the cytotoxic effects of NO liberated from NO-ELIP and their response to NO concentration. Ultrasound-triggered NO release from NO-ELIP using ultrasound activation was studied. It was demonstrated that NO-ELIP remained stable for 5 hours in bovine serum albumin. Delivery of NO using NO-ELIP induced cytotoxicity and programmed cell death of MDA-MB-231 and MDA-MB-468 after 5 hours of incubation. Enhancement of the NO-ELIP effect for therapeutic application was observed with ultrasound activation. This work demonstrates that NO-ELIP can incorporate and deliver NO to breast cancer cells providing increased NO stability and ultrasound-controlled NO release. Improved therapeutic effect with the use of NO-ELIP is expected to be found for breast cancer treatment.