5 resultados para Signal amplitude

em Digital Commons - Montana Tech


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment examined five signal words on safety signs for effectiveness at communicating information about severity of a hazard. Perceived severity was rated by 59 college students for the signal words Deadly, Danger, Warning, Caution, and Notice. Results indicated that Deadly communicated the highest ratings for severity. Danger was second. Warning and Caution were tied for third. The lowest ratings were for Notice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most studies of warning signs involve undergraduate students as subjects. This paper reports a direct comparison of findings from an undergraduate population and an employed population. The 48 employed subjects from this study were compared with 59 undergraduate subjects from a companion study. Subjects from both populations were shown the same signs and asked to rate the severity level connoted by each sign. The signs differed only in signal word. Results for each population indicated that signal word had a highly significant effect on severity ratings. When the two populations were compared for ratings of each signal word, the only significant difference was for Caution. Median ratings of each population were the same: Deadly (4), Danger (3), Warning (2), Caution (1), and Notice (0).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of cryogenic photonic crystals to carry out high performance microwave signal processing operations has been developed into systems that can: rapidly record broadband microwave spectra with fine resolution and high dynamic range; search for patterns in 40 gigabits per second data streams; and communicate via spread- spectrum signals that are well below the noise floor. The basic concepts of the technology and its many applications, along with an overview of university-industry partnerships and the growing photonics industry in Bozeman, will be presented.