3 resultados para ratings of perceived exertion
em Digital Commons - Michigan Tech
Resumo:
From the customer satisfaction point of view, sound quality of any product has become one of the important factors these days. The primary objective of this research is to determine factors which affect the acceptability of impulse noise. Though the analysis is based on a sample impulse sound file of a Commercial printer, the results can be applied to other similar impulsive noise. It is assumed that impulsive noise can be tuned to meet the accepTable criteria. Thus it is necessary to find the most significant factors which can be controlled physically. This analysis is based on a single impulse. A sample impulsive sound file is tweaked for different amplitudes, background noise, attack time, release time and the spectral content. A two level factorial design of experiments (DOE) is applied to study the significant effects and interactions. For each impulse file modified as per the DOE, the magnitude of perceived annoyance is calculated from the objective metric developed recently at Michigan Technological University. This metric is based on psychoacoustic criteria such as loudness, sharpness, roughness and loudness based impulsiveness. Software called ‘Artemis V11.2’ developed by HEAD Acoustics is used to calculate these psychoacoustic terms. As a result of two level factorial analyses, a new objective model of perceived annoyance is developed in terms of above mentioned physical parameters such as amplitudes, background noise, impulse attack time, impulse release time and the spectral content. Also the effects of the significant individual factors as well as two level interactions are also studied. The results show that all the mentioned five factors affect annoyance level of an impulsive sound significantly. Thus annoyance level can be reduced under the criteria by optimizing the levels. Also, an additional analysis is done to study the effect of these five significant parameters on the individual psychoacoustic metrics.
Resumo:
Transformers are very important elements of any power system. Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible selectivity and sensitivity of the protection. Nowadays microprocessor-based relays are widely used to protect power equipment. Current differential and voltage protection strategies are used in transformer protection applications and provide fast and sensitive multi-level protection and monitoring. The elements responsible for detecting turn-to-turn and turn-to-ground faults are the negative-sequence percentage differential element and restricted earth-fault (REF) element, respectively. During severe internal faults current transformers can saturate and slow down the speed of relay operation which affects the degree of equipment damage. The scope of this work is to develop a modeling methodology to perform simulations and laboratory tests for internal faults such as turn-to-turn and turn-to-ground for two step-down power transformers with capacity ratings of 11.2 MVA and 290 MVA. The simulated current waveforms are injected to a microprocessor relay to check its sensitivity for these internal faults. Saturation of current transformers is also studied in this work. All simulations are performed with the Alternative Transients Program (ATP) utilizing the internal fault model for three-phase two-winding transformers. The tested microprocessor relay is the SEL-487E current differential and voltage protection relay. The results showed that the ATP internal fault model can be used for testing microprocessor relays for any percentage of turns involved in an internal fault. An interesting observation from the experiments was that the SEL-487E relay is more sensitive to turn-to-turn faults than advertized for the transformers studied. The sensitivity of the restricted earth-fault element was confirmed. CT saturation cases showed that low accuracy CTs can be saturated with a high percentage of turn-to-turn faults, where the CT burden will affect the extent of saturation. Recommendations for future work include more accurate simulation of internal faults, transformer energization inrush, and other scenarios involving core saturation, using the newest version of the internal fault model. The SEL-487E relay or other microprocessor relays should again be tested for performance. Also, application of a grounding bank to the delta-connected side of a transformer will increase the zone of protection and relay performance can be tested for internal ground faults on both sides of a transformer.
Resumo:
The lack of access to sufficient water and sanitation facilities is one of the largest hindrances towards the sustainable development of the poorest 2.2 billion people in the world. Rural Uganda is one of the areas where such inaccessibility is seriously hampering their efforts at development. Many rural Ugandans must travel several kilometers to fetch adequate water and many still do not have adequate sanitation facilities. Such poor access to clean water forces Ugandans to spend an inordinate amount of time and energy collecting water - time and energy that could be used for more useful endeavors. Furthermore, the difficulty in getting water means that people use less water than they need to for optimal health and well-being. Access to other sanitation facilities can also have a large impact, particularly on the health of young children and the elderly whose immune systems are less than optimal. Hand-washing, presence of a sanitary latrine, general household cleanliness, maintenance of the safe water chain and the households’ knowledge about and adherence to sound sanitation practices may be as important as access to clean water sources. This report investigates these problems using the results from two different studies. It first looks into how access to water affects peoples’ use of it. In particular it investigates how much water households use as a function of perceived effort to fetch it. Operationally, this was accomplished by surveying nearly 1,500 residents in three different districts around Uganda about their water usage and the time and distance they must travel to fetch it. The study found that there is no statistically significant correlation between a family’s water usage and the perceived effort they must put forth to have to fetch it. On average, people use around 15 liters per person per day. Rural Ugandan residents apparently require a certain amount of water and will travel as far or as long as necessary to collect it. Secondly, a study entitled “What Works Best in Diarrheal Disease Prevention?” was carried out to study the effectiveness of five different water and sanitation facilities in reducing diarrheal disease incidences amongst children under five. It did this by surveying five different communities before and after the implementation of improvements to find changes in diarrheal disease incidences amongst children under five years of age. It found that household water treatment devices provide the best means of preventing diarrheal diseases. This is likely because water often becomes contaminated before it is consumed even if it was collected from a protected source.