5 resultados para intra-laboratory testing

em Digital Commons - Michigan Tech


Relevância:

80.00% 80.00%

Publicador:

Resumo:

High concentrations of fluoride naturally occurring in the ground water in the Arusha region of Tanzania cause dental, skeletal and non-skeletal fluorosis in up to 90% of the region’s population [1]. Symptoms of this incurable but completely preventable disease include brittle, discolored teeth, malformed bones and stiff and swollen joints. The consumption of high fluoride water has also been proven to cause headaches and insomnia [2] and adversely affect the development of children’s intelligence [3, 4]. Despite the fact that this array of symptoms may significantly impact a society’s development and the citizens’ ability to perform work and enjoy a reasonable quality of life, little is offered in the Arusha region in the form of solutions for the poor, those hardest hit by the problem. Multiple defluoridation technologies do exist, yet none are successfully reaching the Tanzanian public. This report takes a closer look at the efforts of one local organization, the Defluoridation Technology Project (DTP), to address the region’s fluorosis problem through the production and dissemination of bone char defluoridation filters, an appropriate technology solution that is proven to work. The goal of this research is to improve the sustainability of DTP’s operations and help them reach a wider range of clients so that they may reduce the occurrence of fluorosis more effectively. This was done first through laboratory testing of current products. Results of this testing show a wide range in uptake capacity across batches of bone char emphasizing the need to modify kiln design in order to produce a more consistent and high quality product. The issue of filter dissemination was addressed through the development of a multi-level, customerfunded business model promoting the availability of filters to Tanzanians of all socioeconomic levels. Central to this model is the recommendation to focus on community managed, institutional sized filters in order to make fluoride free water available to lower income clients and to increase Tanzanian involvement at the management level.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recently, water was observed flowing from a section of steep slope along US-2 near St. Ignace, Michigan in addition to soil sloughing in the area where the water is flowing from the slope. An inspection of the area also showed the presence of sinkholes. The original construction drawing for US-2 also indicated that sinkholes were present in this area prior to road construction in 1948. An investigation was conducted to determine the overall stability of the slope. The slope consists primarily of aeolian sand deposits. Laboratory testing determined the shear strength of the slope material to have a friction angle around 30°, which is also the slope angle. Thus, the slope is at its maximum angle for stability—however, the slope is also heavily wooded which provides additional support to the slope. Although the area surrounding the water flow has been sloughing, the remaining slope remains intact.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Geologic hazards affect the lives of millions of people worldwide every year. El Salvador is a country that is regularly affected by natural disasters, including earthquakes, volcanic eruptions and tropical storms. Additionally, rainfall-induced landslides and debris flows are a major threat to the livelihood of thousands. The San Vicente Volcano in central El Salvador has a recurring and destructive pattern of landslides and debris flows occurring on the northern slopes of the volcano. In recent memory there have been at least seven major destructive debris flows on San Vicente volcano. Despite this problem, there has been no known attempt to study the inherent stability of these volcanic slopes and to determine the thresholds of rainfall that might lead to slope instability. This thesis explores this issue and outlines a suggested method for predicting the likelihood of slope instability during intense rainfall events. The material properties obtained from a field campaign and laboratory testing were used for a 2-D slope stability analysis on a recent landslide on San Vicente volcano. This analysis confirmed that the surface materials of the volcano are highly permeable and have very low shear strength and provided insight into the groundwater table behavior during a rainstorm. The biggest factors on the stability of the slopes were found to be slope geometry, rainfall totals and initial groundwater table location. Using the results from this analysis a stability chart was created that took into account these main factors and provided an estimate of the stability of a slope in various rainfall scenarios. This chart could be used by local authorities in the event of a known extreme rainfall event to help make decisions regarding possible evacuation. Recommendations are given to improve the methodology for future application in other areas as well as in central El Salvador.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transformers are very important elements of any power system. Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible selectivity and sensitivity of the protection. Nowadays microprocessor-based relays are widely used to protect power equipment. Current differential and voltage protection strategies are used in transformer protection applications and provide fast and sensitive multi-level protection and monitoring. The elements responsible for detecting turn-to-turn and turn-to-ground faults are the negative-sequence percentage differential element and restricted earth-fault (REF) element, respectively. During severe internal faults current transformers can saturate and slow down the speed of relay operation which affects the degree of equipment damage. The scope of this work is to develop a modeling methodology to perform simulations and laboratory tests for internal faults such as turn-to-turn and turn-to-ground for two step-down power transformers with capacity ratings of 11.2 MVA and 290 MVA. The simulated current waveforms are injected to a microprocessor relay to check its sensitivity for these internal faults. Saturation of current transformers is also studied in this work. All simulations are performed with the Alternative Transients Program (ATP) utilizing the internal fault model for three-phase two-winding transformers. The tested microprocessor relay is the SEL-487E current differential and voltage protection relay. The results showed that the ATP internal fault model can be used for testing microprocessor relays for any percentage of turns involved in an internal fault. An interesting observation from the experiments was that the SEL-487E relay is more sensitive to turn-to-turn faults than advertized for the transformers studied. The sensitivity of the restricted earth-fault element was confirmed. CT saturation cases showed that low accuracy CTs can be saturated with a high percentage of turn-to-turn faults, where the CT burden will affect the extent of saturation. Recommendations for future work include more accurate simulation of internal faults, transformer energization inrush, and other scenarios involving core saturation, using the newest version of the internal fault model. The SEL-487E relay or other microprocessor relays should again be tested for performance. Also, application of a grounding bank to the delta-connected side of a transformer will increase the zone of protection and relay performance can be tested for internal ground faults on both sides of a transformer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis "COMPARATIVE ANALYSIS OF EFFICIENCY AND OPERATING CHARACTERISTICS OF AUTOMOTIVE POWERTRAIN ARCHITECTURES THROUGH CHASSIS DYNAMOMETER TESTING" was completed through a collaborative partnership between Michigan Technological University and Argonne National Laboratory under a contractual agreement titled "Advanced Vehicle Characterization at Argonne National Laboratory". The goal of this project was to investigate, understand and document the performance and operational strategy of several modern passenger vehicles of various architectures. The vehicles were chosen to represent several popular engine and transmission architectures and were instrumented to allow for data collection to facilitate comparative analysis. In order to ensure repeatability and reliability during testing, each vehicle was tested over a series of identical drive cycles in a controlled environment utilizing a vehicle chassis dynamometer. Where possible, instrumentation was preserved between vehicles to ensure robust data collection. The efficiency and fuel economy performance of the vehicles was studied. In addition, the powertrain utilization strategies, significant energy loss sources, tailpipe emissions, combustion characteristics, and cold start behavior were also explored in detail. It was concluded that each vehicle realizes different strengths and suffers from different limitations in the course of their attempts to maximize efficiency and fuel economy. In addition, it was observed that each vehicle regardless of architecture exhibits significant energy losses and difficulties in cold start operation that can be further improved with advancing technology. It is clear that advanced engine technologies and driveline technologies are complimentary aspects of vehicle design that must be utilized together for best efficiency improvements. Finally, it was concluded that advanced technology vehicles do not come without associated cost; the complexity of the powertrains and lifecycle costs must be considered to understand the full impact of advanced vehicle technology.