Power distribution systems are susceptible to extreme damage from natural hazards especially hurricanes. Hurricane winds can knock down distribution poles thereby causing damage to the system and power outages which can result in millions of dollars in lost revenue and restoration costs. Timber has been the dominant material used to support overhead lines in distribution systems. Recently however, utility companies have been searching for a cost-effective alternative to timber poles due to environmental concerns, durability, high cost of maintenance and need for improved aesthetics. Steel has emerged as a viable alternative to timber due to its advantages such as relatively lower maintenance cost, light weight, consistent performance, and invulnerability to wood-pecker attacks. Both timber and steel poles are prone to deterioration over time due to decay in the timber and corrosion of the steel. This research proposes a framework for conducting fragility analysis of timber and steel poles subjected to hurricane winds considering deterioration of the poles over time. Monte Carlo simulation was used to develop the fragility curves considering uncertainties in strength, geometry and wind loads. A framework for life-cycle cost analysis is also proposed to compare the steel and timber poles. The results show that steel poles can have superior reliability and lower life-cycle cost compared to timber poles, which makes them suitable substitutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Humid Chaco of Northeast Paraguay harbors monoculture palm savannas in which Copernicia alba is the only dominant overstory species. The study’s objective was to provide the complete spatial distribution of a simple ecosystem lacking confounding factors of overstory competition and changes in slope. Palms within six, 50 x 50m plots were marked by their GPS location and measured for dbh and total stem height. The spatial distribution was individually analyzed for each plot at the local scale up to 12 m using Ripley’s K test. For the total population including juvenile and adult plants, the sample plots contained both random and clustered distribution patterns. In each of the six plots, the juvenile populations exhibited more clustered patterns than the adult population of each plot.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reed canary grass (Phalaris arundinacea L.) is an invasive species originally from Europe that has now expanded to a large range within the United States. Reed canary grass possesses a number of traits that allow it to thrive in a wide range of environmental factors, including high rates of sedimentation, bouts of flooding, and high levels of nutrient inputs. Therefore, the goals of our study were to determine if 1) certain types of wetland were more susceptible to Reed canary grass invasion, and 2) disturbances facilitated Reed canary grass invasion. This study was conducted within the Keweenaw Bay Indian Community reservation in the Upper Peninsula of Michigan, in Baraga County. We selected 28 wetlands for analysis. At each wetland, we identified and sampled distinct vegetative communities and their corresponding environmental attributes, which included water table depth, pH, conductivity, calcium and magnesium concentrations, and percent organic matter. Disturbances at each site were catalogued and their severity estimated with the aid of aerial photos. A GIS dataset containing information about the location of Reed canary grass within the study wetlands, the surrounding roads and the level of roadside Reed canary grass invasion was also developed. In all, 287 plant species were identified and classified into 16 communities, which were then further grouped into three broad groupings of wetlands: nonforested graminoid, Sphagnum peatlands, and forested wetlands. The two most common disturbances identified were roads and off-road recreation trails, both occurring at 23 of the 28 sites. Logging activity surrounding the wetlands was the next most common disturbance and was found at 18 of the sites. Occurrence of Reed canary grass was most common in the non-forested graminoid communities. Reed canary grass was very infrequent in forested wetlands, and almost never occurred in the Sphagnum peatlands. Disturbance intensity was the most significant environmental factor in explaining Reed canary grass occurrence within wetlands. Statistically significant relationships were identified at distances of 1000 m, 500 m, and 250 m from studied wetlands, between the level of road development and the severity of Reed canary grass invasion along roadsides. Further analysis revealed a significant relationship between roadside Reed canary grass populations and the level of road development (e.g. paved, graded, and ungraded).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power transformers are key components of the power grid and are also one of the most subjected to a variety of power system transients. The failure of a large transformer can cause severe monetary losses to a utility, thus adequate protection schemes are of great importance to avoid transformer damage and maximize the continuity of service. Computer modeling can be used as an efficient tool to improve the reliability of a transformer protective relay application. Unfortunately, transformer models presently available in commercial software lack completeness in the representation of several aspects such as internal winding faults, which is a common cause of transformer failure. It is also important to adequately represent the transformer at frequencies higher than the power frequency for a more accurate simulation of switching transients since these are a well known cause for the unwanted tripping of protective relays. This work develops new capabilities for the Hybrid Transformer Model (XFMR) implemented in ATPDraw to allow the representation of internal winding faults and slow-front transients up to 10 kHz. The new model can be developed using any of two sources of information: 1) test report data and 2) design data. When only test-report data is available, a higher-order leakage inductance matrix is created from standard measurements. If design information is available, a Finite Element Model is created to calculate the leakage parameters for the higher-order model. An analytical model is also implemented as an alternative to FEM modeling. Measurements on 15-kVA 240?/208Y V and 500-kVA 11430Y/235Y V distribution transformers were performed to validate the model. A transformer model that is valid for simulations for frequencies above the power frequency was developed after continuing the division of windings into multiple sections and including a higher-order capacitance matrix. Frequency-scan laboratory measurements were used to benchmark the simulations. Finally, a stability analysis of the higher-order model was made by analyzing the trapezoidal rule for numerical integration as used in ATP. Numerical damping was also added to suppress oscillations locally when discontinuities occurred in the solution. A maximum error magnitude of 7.84% was encountered in the simulated currents for different turn-to-ground and turn-to-turn faults. The FEM approach provided the most accurate means to determine the leakage parameters for the ATP model. The higher-order model was found to reproduce the short-circuit impedance acceptably up to about 10 kHz and the behavior at the first anti-resonant frequency was better matched with the measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water distribution systems are important for life saving facilities especially in the recovery after earthquakes. In this paper, a framework is discussed about seismic serviceability of water systems that includes the fragility evaluation of water sources of water distribution networks. Also, a case study is brought about the performance of a water system under different levels of seismic hazard. The seismic serviceability of a water supply system provided by EPANET is evaluated under various levels of seismic hazard. Basically, the assessment process is based on hydraulic analysis and Monte Carlo simulations, implemented with empirical fragility data provided by the American Lifeline Alliance (ALA, 2001) for both pipelines and water facilities. Represented by the Seismic Serviceability Index (Cornell University, 2008), the serviceability of the water distribution system is evaluated under each level of earthquakes with return periods of 72 years, 475 years, and 2475 years. The system serviceability under levels of earthquake hazard are compared with and without considering the seismic fragility of the water source. The results show that the seismic serviceability of the water system decreases with the growing of the return period of seismic hazard, and after considering the seismic fragility of the water source, the seismic serviceability decreases. The results reveal the importance of considering the seismic fragility of water sources, and the growing dependence of the system performance of water system on the seismic resilience of water source under severe earthquakes.