6 resultados para Two-component Regulatory System
em Digital Commons - Michigan Tech
Resumo:
For a fluid dynamics experimental flow measurement technique, particle image velocimetry (PIV) provides significant advantages over other measurement techniques in its field. In contrast to temperature and pressure based probe measurements or other laser diagnostic techniques including laser Doppler velocimetry (LDV) and phase Doppler particle analysis (PDPA), PIV is unique due to its whole field measurement capability, non-intrusive nature, and ability to collect a vast amount of experimental data in a short time frame providing both quantitative and qualitative insight. These properties make PIV a desirable measurement technique for studies encompassing a broad range of fluid dynamics applications. However, as an optical measurement technique, PIV also requires a substantial technical understanding and application experience to acquire consistent, reliable results. Both a technical understanding of particle image velocimetry and practical application experience are gained by applying a planar PIV system at Michigan Technological University’s Combustion Science Exploration Laboratory (CSEL) and Alternative Fuels Combustion Laboratory (AFCL). Here a PIV system was applied to non-reacting and reacting gaseous environments to make two component planar PIV as well as three component stereographic PIV flow field velocity measurements in conjunction with chemiluminescence imaging in the case of reacting flows. This thesis outlines near surface flow field characteristics in a tumble strip lined channel, three component velocity profiles of non-reacting and reacting swirled flow in a swirl stabilized lean condition premixed/prevaporized-fuel model gas turbine combustor operating on methane at 5-7 kW, and two component planar PIV measurements characterizing the AFCL’s 1.1 liter closed combustion chamber under dual fan driven turbulent mixing flow.
Resumo:
In the current market system, power systems are operated at higher loads for economic reasons. Power system stability becomes a genuine concern in such operating conditions. In case of failure of any larger component, the system may become stressed. These events may start cascading failures, which may lead to blackouts. One of the main reasons of the major recorded blackout events has been the unavailability of system-wide information. Synchrophasor technology has the capability to provide system-wide real time information. Phasor Measurement Units (PMUs) are the basic building block of this technology, which provide the Global Positioning System (GPS) time-stamped voltage and current phasor values along with the frequency. It is being assumed that synchrophasor data of all the buses is available and thus the whole system is fully observable. This information can be used to initiate islanding or system separation to avoid blackouts. A system separation strategy using synchrophasor data has been developed to answer the three main aspects of system separation: (1) When to separate: One class support machines (OC-SVM) is primarily used for the anomaly detection. Here OC-SVM was used to detect wide area instability. OC-SVM has been tested on different stable and unstable cases and it is found that OC-SVM has the capability to detect the wide area instability and thus is capable to answer the question of “when the system should be separated”. (2) Where to separate: The agglomerative clustering technique was used to find the groups of coherent buses. The lines connecting different groups of coherent buses form the separation surface. The rate of change of the bus voltage phase angles has been used as the input to this technique. This technique has the potential to exactly identify the lines to be tripped for the system separation. (3) What to do after separation: Load shedding was performed approximately equal to the sum of power flows along the candidate system separation lines should be initiated before tripping these lines. Therefore it is recommended that load shedding should be initiated before tripping the lines for system separation.
Resumo:
In recent years, security of industrial control systems has been the main research focus due to the potential cyber-attacks that can impact the physical operations. As a result of these risks, there has been an urgent need to establish a stronger security protection against these threats. Conventional firewalls with stateful rules can be implemented in the critical cyberinfrastructure environment which might require constant updates. Despite the ongoing effort to maintain the rules, the protection mechanism does not restrict malicious data flows and it poses the greater risk of potential intrusion occurrence. The contributions of this thesis are motivated by the aforementioned issues which include a systematic investigation of attack-related scenarios within a substation network in a reliable sense. The proposed work is two-fold: (i) system architecture evaluation and (ii) construction of attack tree for a substation network. Cyber-system reliability remains one of the important factors in determining the system bottleneck for investment planning and maintenance. It determines the longevity of the system operational period with or without any disruption. First, a complete enumeration of existing implementation is exhaustively identified with existing communication architectures (bidirectional) and new ones with strictly unidirectional. A detailed modeling of the extended 10 system architectures has been evaluated. Next, attack tree modeling for potential substation threats is formulated. This quantifies the potential risks for possible attack scenarios within a network or from the external networks. The analytical models proposed in this thesis can serve as a fundamental development that can be further researched.
Resumo:
In 2005, Wetland Studies and Solutions, Inc. (WSSI) installed an extensive Low Impact Development (LID) stormwater management system on their new office site in Gainesville, Virginia. The 4-acre site is serviced by a network of LID components: permeable pavements (two proprietary and one gravel type), bioretention cell / rain garden, green roof, vegetated swale, rainwater harvesting and drip irrigation, and slow-release underground detention. The site consists of heavy clay soils, and the LID components are mostly integrated by a series of underdrain pipes. A comprehensive monitoring system has been designed and installed to measure hydrologic performance throughout the LID, underdrained network. The monitoring system measures flows into and out of each LID component independently while concurrently monitoring rainfall events. A sensitivity analysis and laboratory calibration has been performed on the flow measurement system. Field data has been evaluated to determine the hydrologic performance of the LID features. Finally, hydrologic models amenable to compact, underdrained LID sites have been reviewed and recommended for future modeling and design.
Resumo:
It is an important and difficult challenge to protect modern interconnected power system from blackouts. Applying advanced power system protection techniques and increasing power system stability are ways to improve the reliability and security of power systems. Phasor-domain software packages such as Power System Simulator for Engineers (PSS/E) can be used to study large power systems but cannot be used for transient analysis. In order to observe both power system stability and transient behavior of the system during disturbances, modeling has to be done in the time-domain. This work focuses on modeling of power systems and various control systems in the Alternative Transients Program (ATP). ATP is a time-domain power system modeling software in which all the power system components can be modeled in detail. Models are implemented with attention to component representation and parameters. The synchronous machine model includes the saturation characteristics and control interface. Transient Analysis Control System is used to model the excitation control system, power system stabilizer and the turbine governor system of the synchronous machine. Several base cases of a single machine system are modeled and benchmarked against PSS/E. A two area system is modeled and inter-area and intra-area oscillations are observed. The two area system is reduced to a two machine system using reduced dynamic equivalencing. The original and the reduced systems are benchmarked against PSS/E. This work also includes the simulation of single-pole tripping using one of the base case models. Advantages of single-pole tripping and comparison of system behavior against three-pole tripping are studied. Results indicate that the built-in control system models in PSS/E can be effectively reproduced in ATP. The benchmarked models correctly simulate the power system dynamics. The successful implementation of a dynamically reduced system in ATP shows promise for studying a small sub-system of a large system without losing the dynamic behaviors. Other aspects such as relaying can be investigated using the benchmarked models. It is expected that this work will provide guidance in modeling different control systems for the synchronous machine and in representing dynamic equivalents of large power systems.
Resumo:
Microbial fuel cell (MFC) research has focused mostly on producing electricity using soluble organic and inorganic substrates. This study focused on converting solid organic waste into electricity using a two-stage MFC process. In the first stage, a hydrolysis reactor produced soluble organic substrates from solid organic waste. The soluble substrates from the hydrolysis reactor were pumped to the second stage reactor: a continuous-flow, air-cathode MFC. Maximum power output (Pmax) of the MFC was 296 mW/m3 at a current density of 25.4 mA/m2 while being fed only leachate from the first stage reactor. Addition of phosphate buffer increased Pmax to 1,470 mW/m3 (89.4 mA/m2), although this result could not be duplicated with repeated polarization testing. The minimum internal resistance achieved was 77 Omega with leachate feed and 17 Omega with phosphate buffer. The low coulombic efficiency (