A significant cost for foundations is the design and installation of piles when they are required due to poor ground conditions. Not only is it important that piles be designed properly, but also that the installation equipment and total cost be evaluated. To assist in the evaluation of piles a number of methods have been developed. In this research three of these methods were investigated, which were developed by the Federal Highway Administration, the US Corps of Engineers and the American Petroleum Institute (API). The results from these methods were entered into the program GRLWEAPTM to assess the pile drivability and to provide a standard base for comparing the three methods. An additional element of this research was to develop EXCEL spreadsheets to implement these three methods. Currently the Army Corps and API methods do not have publicly available software and must be performed manually, which requires that data is taken off of figures and tables, which can introduce error in the prediction of pile capacities. Following development of the EXCEL spreadsheet, they were validated with both manual calculations and existing data sets to ensure that the data output is correct. To evaluate the three pile capacity methods data was utilized from four project sites from North America. The data included site geotechnical data along with field determined pile capacities. In order to achieve a standard comparison of the data, the pile capacities and geotechnical data from the three methods were entered into GRLWEAPTM. The sites consisted of both cohesive and cohesionless soils; where one site was primarily cohesive, one was primarily cohesionless, and the other two consisted of inter-bedded cohesive and cohesionless soils. Based on this limited set of data the results indicated that the US Corps of Engineers method more closely compared with the field test data, followed by the API method to a lesser degree. The DRIVEN program compared favorably in cohesive soils, but over predicted in cohesionless material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis focuses on the impact of the American shale gas boom on the European natural gas market. The study presents different tests in order to analyze the dynamics of natural gas prices in the U.S., U.K. and German natural gas market. The question of cointegration between these different markets are analyzed using several tests. More specifically, the ADF tests for the presence of a unit root. The error correction model test and the Johansen cointegration procedure are applied in order to accept or reject the hypothesis of an integrated market. The results suggest no evidence of cointegration between these markets. There currently is no evidence of an impact of the U.S. shale gas boom on the European market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several modern-day cooling applications require the incorporation of mini/micro-channel shear-driven flow condensers. There are several design challenges that need to be overcome in order to meet those requirements. The difficulty in developing effective design tools for shear-driven flow condensers is exacerbated due to the lack of a bridge between the physics-based modelling of condensing flows and the current, popular approach based on semi-empirical heat transfer correlations. One of the primary contributors of this disconnect is a lack of understanding caused by the fact that typical heat transfer correlations eliminate the dependence of the heat transfer coefficient on the method of cooling employed on the condenser surface when it may very well not be the case. This is in direct contrast to direct physics-based modeling approaches where the thermal boundary conditions have a direct and huge impact on the heat transfer coefficient values. Typical heat transfer correlations instead introduce vapor quality as one of the variables on which the value of the heat transfer coefficient depends. This study shows how, under certain conditions, a heat transfer correlation from direct physics-based modeling can be equivalent to typical engineering heat transfer correlations without making the same apriori assumptions. Another huge factor that raises doubts on the validity of the heat-transfer correlations is the opacity associated with the application of flow regime maps for internal condensing flows. It is well known that flow regimes influence heat transfer rates strongly. However, several heat transfer correlations ignore flow regimes entirely and present a single heat transfer correlation for all flow regimes. This is believed to be inaccurate since one would expect significant differences in the heat transfer correlations for different flow regimes. Several other studies present a heat transfer correlation for a particular flow regime - however, they ignore the method by which extents of the flow regime is established. This thesis provides a definitive answer (in the context of stratified/annular flows) to: (i) whether a heat transfer correlation can always be independent of the thermal boundary condition and represented as a function of vapor quality, and (ii) whether a heat transfer correlation can be independently obtained for a flow regime without knowing the flow regime boundary (even if the flow regime boundary is represented through a separate and independent correlation). To obtain the results required to arrive at an answer to these questions, this study uses two numerical simulation tools - the approximate but highly efficient Quasi-1D simulation tool and the exact but more expensive 2D Steady Simulation tool. Using these tools and the approximate values of flow regime transitions, a deeper understanding of the current state of knowledge in flow regime maps and heat transfer correlations in shear-driven internal condensing flows is obtained. The ideas presented here can be extended for other flow regimes of shear-driven flows as well. Analogous correlations can also be obtained for internal condensers in the gravity-driven and mixed-driven configuration.